The following replaces steps 1 through 4, page 11, in the printed LXD-75 manual. Figure numbers refer to Figures 1c and 1d, pages 4 and 5, in the man­ual, or are included on this page.
Thread shaft through the mounting base
Braces
Tension
Knob
T-Handle
Fig. 4: Thread T-handle shaft into base. (See next page.)
Fig. 5a: Slide bushing over shaft.
Spreader Bar
Bushing
Second slot
Second slot
How to Assemble Your Telescope
The giftboxes contain the optical tube assembly and the tripod with the equatorial mount. The accessories are located within compartments custom-cut into the styrofoam block inserts.
Remove the components from the giftboxes: Remove and identify the tele-
1.
scope’s equipment. Refer to Figures 1a through 1f for images of the parts and the overall assembly of your telescope. When removing the tripod from the gift­box, hold the assembly parallel (horizontal) to the ground or the inner tripod leg extensions will slide out as they are not locked in place.
Adjust the tripod legs. Spread the tripod legs as far as they will open. See Fig. 3.
2.
Attach the spreader bar to the tripod with shaft: Thread the tension knob onto
3.
the shaft (see Fig. 4). Place the spreader bar (36, Fig. 1c) over the T-handle shaft. Slide the bushing, the wide open side facing downward, onto the shaft as far as it will go (Fig. 5a). Then slide the shaft up through the tripod mounting base
37, Fig. 1c). Above the mount, snap the c-clip into the second, narrower precut
( slot (see Fig. 5a) of the shaft (Fig. 5b).
4. Attach mount to tripod base: Place the mount over the tripod mounting base (37, Fig. 1c) and onto the shaft, with the protrusion on top of the tripod's base positioned between the fine azimuth control knobs ( necessary, back off the azimuth control knobs wide enough for protrusion to fit between them.
Tighten the T-handle to a firm feel. This attachment keeps the tripod and the tel­escope mount securely in place. Then line up the spreader bar braces so that they are each touching one of the tripods legs. Tighten the tension knob ( 1c) to a firm feel. When you wish to collapse the tripod, loosen the tension knob and move the braces off the legs. You do not need to remove the T-handle/shaft.
Continue with Step 5, as presented in the printed manual.
27, Fig. 1d). See Fig. 5c. If
39, Fig.
C-clip
Fig. 5b: Snap c-clip all the way onto shaft above mount (shown partially attached).
Fine Azimuth Control Knobs
Protrusion
Fig. 5c: Attach the mount to the tripod.
Place mount over shaft with bushing and c-clip.
Meade Customer Service
If you have a question concerning your LXD75-Series telescope, contact the Meade Instruments Customer Service Department at:
Telephone: (949) 451-1450 Customer Service hours are 7:00 AM to 6:00 PM, Pacific Time, Monday through
Friday. In the unlikely event that your LXD75-Series telescope requires factory servic- ing or repairs, write or call the Meade Customer Service Department first, before returning the telescope to the factory, giving full particulars as to the nature of the problem, as well as your name, address, and daytime telephone number. The great majority of servicing issues can be resolved by telephone, avoiding return of the tele­scope to the factory. If factory service is required, you will be assigned a Return Goods Authorization (RGA) number prior to return.