Maytag MFS18 User Manual

INSTALLATION INSTRUCTIONS
MFS18, MFS25, MFS35, MFS55
COMMERCIAL WASHER
TABLE OF CONTENTS
WASHER SAFETY .................................................................. 2
INSTALLATION REQUIREMENTS ......................................... 3
Tools and Parts ...................................................................... 3
Optional Equipment .............................................................. 3
Location Requirements ........................................................ 3
...Electrical Requirements ........................................................ 6
Water Supply Requirements ................................................. 7
Drain Requirements .............................................................. 7
Laundry Product Dispenser Pumps ...................................... 7
INSTALLATION INSTRUCTIONS ........................................... 8
Inspection and Storage ........................................................ 8
Mechanical Installation ......................................................... 8
Remove Shipping Brackets .................................................. 8
Electrical Connection ........................................................... 9
Water Supply Connection .................................................... 9
Drain Connection .................................................................. 9
Laundry Product Supply Pump Connection ......................... 9
Complete Installation .......................................................... 10
Break-In Period .................................................................. 10
Controls Troubleshooting ................................................... 10
Maintenance Schedule .......................................................... 11
Belt Inspection, Adjustment, and Replacement ....................12
Door Seal Adjustment and Replacement ..............................12
Fuse Replacement ................................................................13
Opening Door Without Power ..............................................13
DIMENSIONS AND TECHNICAL SPECIFICATIONS . .............14
Dimensions ............................................................................14
Component Locations ...........................................................15
Technical Specications ........................................................16
Torque Specications ............................................................16
W10214572C
www.maytagcommerciallaundry.com
1
WASHER SAFETY
IMPORTANT:
This washer must be directly wired to the electrical system
and may not be attached with a plug.
The circuit must be a dedicated circuit and may not be
combined with any lighting circuit.
Adequate grounding is essential to washer operation.
2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed:
These washers must be installed by professional installers. The installer should have a full compliment of standard SAE and metric hand tools as well as other specialized tools as required.
Additional materials required:
Additional materials required vary with the type of installation. The customer is responsible for supplying additional hardware and adapters as necessary.
Parts supplied:
Remove parts bag from washer drum. Check that all parts were included. The number of parts supplied varies with model.
Molded rubber drain hose and band clamp
Rubber washers for the hoses (4 or 6)
Water supply hoses (2 or 3)
Optional Equipment
The following optional equipment is available for these washers.
Steam Heater Kit
Steam heating kits is available for Model MFS55 only. To add a steam kit to your washer, order the kit specied in the table below:
Model Steam Kit Number
MFS55PNA W10308483
Location Requirements
Washers should be installed on a level concrete oor on the ground level of a building; they can also be installed on an elevated concrete pad up to 12" (300 mm) above the surrounding oor. Consult a structural engineer to approve other locations. The models MFS18 and MFS25 washers can also be mounted on an elevated metal base up to 12" (300 mm) high.
Proper installation is your responsibility. The installation must meet all governing codes and ordinances.
You will need:
The washer should be located in a building and not directly
exposed to the weather. The temperature of the building should be 40–95°F (5–35°C) during operation.
A hot water heater set between 120–160°F (49–80°C).
Valved hot and cold water supply (3/4" male NPT tting)
within 4 ft. (1.2 m) of the washer with a water pressure between 43 and 73 PSI (0.3–0.5 MPa).
A dedicated, GFCI-equipped circuit for each washer (see
“Electrical Requirements”).
Adequate sanitary sewer drainage located behind each
washer.
A solid concrete oor or slab capable of withstanding the
weight and vibration produced by the washer. The maximum slope of the oor is 1" (25 mm) under the washer. A rough concrete surface is preferable to a smooth or covered surface when the washer is not secured, to keep the washer from walking during extraction cycles.
Minimum Installation Clearances:
The location must be large enough to allow the washer door to open completely.
There should be adequate access behind and above the
washer for maintenance and service.
3
PP
27.6" (701 mm)
C
A
B
D
12"
(300 mm)
max. elevation
Front View
MFS18 MFS25 MFS35 MFS55
0.6" (15 mm) 0.6" (15 mm) 0.8" (20 mm) 0.8" (20 mm)
P
* Door may not open completely with this minimum clearance
23.6" (600 mm)
Dim. Model
MFS18 MFS25 MFS35 MFS55
A 25.99"
(660 mm)
B
C
D
28.15"
(715 mm)
42.50"
(1080 mm)
44.50"
(1130 mm)
25.99"
(660 mm)
32.48"
(825 mm)
44.90"
(1140 mm)
48.40"
(1230 mm)
32.67"
(830 mm)
38.39"
(975 mm)
51.00"
(1300 mm)
58.70"
(1490 mm)
35.46"
(901 mm)
36.40"
(925 mm)
56.30"
(1430 mm)
63.60"
(1620 mm)
Installation on an elevated base
NOTES:
Models MFS35 and MFS55 are mountable on either a metal
base or an elevated cement slab; however, they must be adequately secured.
Minimum clearances should be maintained when installing
washers in an elevated position.
Fixed Installation on Concrete Floor or Elevated Concrete Pad (all models)
All washer models can be installed on an elevated cement slab. The base must be able to withstand both the load and vibration of the washer. The washer must be secured with anchor bolts (See “Installation Instructions”). Install the 4 anchors before nal installation of the washer.
4" (100 mm)
Side View
Product Dimensions
General product dimensions are shown below. See Technical Specications for dimensions not shown here.
4
Freestanding Installation on Elevated Concrete Pad (Models MFS18 and MFS25 only)
Models MFS18 and MFS25 can be installed on an elevated concrete pad without bolts by installing a metal channel at the front of the concrete pad to secure the front washer mounting feet. Specications of the metal channel are shown in the gure below. The channel must be rmly secured with anchors or self-tapping cement screws.
0.63"
2.38"
(60 mm)
(15 mm)
0.160"
(4 mm)
min.
12"
(300 mm)
max.
Elevated Metal Base for Secured Installation
0.160"
(4 mm)
min.
12"
(300 mm)
max.
The elevated metal base for a secured installation may be fabricated from a metal U-channel as shown in the illustration below. The maximum allowable height of the base is 12" (300 mm). The base must be able to withstand both the load and vibration of the washer. The base must be adequately secured with anchor bolts or cement anchors.
Dim. Model
MFS18 MFS25 MFS35 MFS55
X4 3.81"
(97 mm)
X5
(min.)
4.53"
(115 mm)
X6 5.12"
(130 mm)
X7 2.76"
(70 mm)
3.42"
(87 mm)
4.53"
(115 mm)
5.12"
(130 mm)
2.76"
(70 mm)
1.97"
(50 mm)
5.32"
(135 mm)
3.15"
(80 mm)
1.77"
(45 mm)
1.06"
(27 mm)
4.76"
(121 mm)
1.55"
(39.5 mm)
6.69"
(170 mm)
Elevated Metal Base for Freestanding Installation (Models MFS18 and MFS25 only)
Minimum material thickness 0.160" (4 mm)
U-Channel
Anchor Bolt Placement
X7
X4
BC
X2
X6
X3
X1
D
A
A
The elevated metal base for a freestanding installation must be constructed in the same way as the base for a secured installation. An additional U channel must be welded or bolted to the top of the front rail to secure the front washer mounting feet (see illustration below).
A
B
Minimum material thickness 0.160" (4 mm)
X5
U-Channel
Outline of cabinet Outline of frame
Outline of riser
Inside of riser
X3
2.38"
(60 mm)
0.19"
(5 mm)
B
0.63"
(15 mm)
12"
(300 mm)
max.
Dim. Model
MFS18 MFS25 MFS35 MFS55
A 25.99"
B 28.15"
C 17.91"
D 22.05"
X1 1.14"
X2 3.46"
X3 1.97"
(660 mm)
(715 mm)
(455 mm)
(560 mm)
(29 mm)
(88 mm)
(50 mm)
25.99"
(660 mm)
32.48"
(825 mm)
22.24"
(565 mm)
22.05"
(560 mm)
1.14"
(29 mm)
3.46"
(88 mm)
1.97"
(50 mm)
32.67"
(830 mm)
38.39"
(975 mm)
32.09"
(815 mm)
28.15"
(715 mm)
1.18"
(30 mm)
1.97"
(50 mm)
2.26"
(57.5 mm)
35.46"
(901 mm)
36.40"
(925 mm)
33.30"
(846 mm)
31.50"
(800 mm)
1.77"
(45 mm)
1.06"
(27 mm)
1.98"
(50.5 mm)
5
Loading...