Control Unit SG-RSV 2X9 Operating Instructions
Control Unit
in accordance with EN 50155 and
EN 50121-3-2
class S2 in accordance with
EN 50155
EN 954 Category 2
EN 50129 SIL1
for sensors with monitoring resistor
1k2
These operating instruction apply to the
following control units:
1004156 SG-RSV 209 2s 24 V =
1004155 SG-RSV 209 8s 24 V =
1004093 SG-RSV 209 12s 24 V =
1004764 SG-RSV 219 2s 110 V =
1004765 SG-RSV 219 8s 110 V =
1004091 SG-RSV 219 12s 110 V =
Relay
“fault”
Relay
“activated”
Relay
“monitoring loop”
Sensor 1 Sensor 2
Control system
The Control Unit has two monitoring
circuits which operate the output relays.
The electronics monitor the electrical
resistance of the connected sensors
which have a dened zero signal
current.
When the sensors are not activated
(normal operating conditions), the output relays are energised.
If a break occurs in the supply line between the sensor and the control unit,
the relays “fault” and “monitoring loop”
are deactivated.
Depending on the internal train signals
and the sensors, the relays “activated”
and “monitoring loop” are deactivated.
Enclosure
W × H × D (mm) 45 × 75 × 108
Protection class IP20
Plug connection 2× 8-pin
Cable clamps max. 2.5 mm
Weight approx. 195 g
2
Parts supplied
Version 5
Mayser Polymer Electric Postfach 30 48 89020 Ulm GERMANY Tel. +49 731 2061-0 Fax +49 731 2061-222
250609 v2.5
- Control Unit
Enclosure with electronics module
and plug connections with lift-up lock
release.
- Operating Instructions
![](/html/71/71b5/71b53e04b35acaf15c4073cded2df474e7a8ccee207b13fcc8c0989fec399b79/bg2.png)
Mayser Polymer Electric Postfach 30 48 89020 Ulm GERMANY Tel. +49 731 2061-0 Fax +49 731 2061-222
250609 v2.5
Page 2/6
Control Unit SG-RSV 2X9
IMPORTANT NOTES! Please read!
To ensure correct and safe operation
of the unit, it must be properly transported and stored, properly installed
and commissioned, and operated in
accordance with its intended use.
Only persons familiar with the installation, commissioning and operation,
and with the corresponding qualications to prove their skills, may work
on the units. They must observe the
contents of these instructions, the
information given on the type plate of
the unit and the relevant safety regulations for the installation and operation
of electrical systems.
This unit is designed and tested in
accordance with EN 50155 and EN
50121-3-2 and left the factory in a
perfectly safe condition. To maintain this
condition, you must observe the safety
regulations marked WARNING! in these
operating instructions. Failure to
observe the safety regulations can lead
to death, injury to personnel, or damage
to the unit and other systems and
equipment.
Should the information given in these
operating instructions be inadequate
in any way, please contact your local
technical centre, subsidiary or representative.
Technical Data
Connecting voltage US
SG-RSV 209 DC 24 V (S2)
SG-RSV 219 DC 110 V (S2)
SG-RSV 279 DC 72 V (S2)
Voltage tolerance -30% to +30%
Nominal frequency Frequency tolerance Power consumption < 3 W
Times
Follow-through time tN 200 ms
Extension time tD 0.1 to 2.5 s
factory setting: 200 ms
Active time tA 2 to 15 s
factory setting: 2 s, 8 s or 12 s
Sensor voltage
max. DC 12 V
When using the device outside the
European Union, you must observe
the relevant regulations valid for the
country of use.
Important notes:
- Supply voltage
must correspond to the connecting
voltage Us on the type plate.
- Permissible temperature range
When installing in switch cabinet,
maintain sufcient distance from heat
sources (min. 2 cm).
- Fusing of the relay contacts
due to risk of welding, externally with
1.0 A inert.
Switching thresholds at +23 °C Y1 / Y2 Y3 / Y4
activated < 430 Ohm < 430 Ohm
cable break > 2k5 >2k5
Status sensor voltage
Relay data AC 12 DC 12
Switching current max. 1 A max. 1 A
Switching voltage max. AC 250 V max. DC 150 V
Breaking capacity max. 250 W max. 30 W
(AC 12) (DC 12)
Switching operations
mechanical > 2× 10
electrical > 1× 105 (AC 250 V / 1 A)
Operating conditions
Perm. ambient temperature -30 °C to +70 °C
Rel. humidity max. 95%
Vibration fatigue limit
Frequency range 5 to 150 Hz
Excursion amplitude ± 2 mm
Acceleration amplitude 5 g in all 3 levels
max. U
s
7
Note:
When switching inductive loads the user
must be tted out with spark absorbers.