Mayser SG-RSV 205 User Manual

Polymer Electric
Control Unit SG-RSV 205
Sensor 1 Sensor 2
Operating Instructions
Control Unit
Category 1 as per EN 954-1
for sensors with
1.2 k monitoring resistor
These operating instructions apply to the following control units:
SG-RSV 205/2 Semiconductor
outputs
Control
This control unit contains two monitoring circuits that act on two load circuits.
SG-RSV 205
The electronics monitor the resistance of the connected sensors which have a specific closed-circuit current.
The outputs are short circuit proof semiconductor outputs.
U
S
Enclosure
W x H x D (mm) 58 x 30 x 30 Protection class enclosure IP 40 Plug connection Flat plug 6,3 x 0,8 Weight c. 70 g
Mayser Polymer Electric P.O. Box 3048 D-89020 Ulm Tel. +49 731 2061-0 Fax +49 731 2061-222
060902
Installation and Operation
Technical Data
Connecting Voltage U
SG-RSV 205 DC 18 - 32 V Power consumption max. 2.5 W
Inputs
Input voltage U Input current I
Outputs (PNP)
Switching voltage U
Switching current I Response time t
Permissible ambient temperature - 40 °C to + 80 °C
S
0 - 16 V 0 - 21 mA
min. US - 1.0 V max. 0.5 V max. 0.4 A < 5 ms
U
E
E
A, high
A, low
A
SG
Polymer Electric
Important notes:
- if only one sensor is being used
When using only one sensor, bridge the second input with a 1,2 k resistor.
Output "Betätigt" (activated)
Output "Störung" (fault) Model 205/2
Installation
Fit all 7 flat plugs onto the appropriate sockets and then insert them uniformly.
Connector assignment: Supply voltage A1(+), A2 (–)
Semiconductor outputs 1, 2 Sensor 1 Y1, Y2 Sensor 2 Y3, Y4
Commissioning
Output behaviour
activated fault normalnormaloff
(1)
(2)
low
high
normal
Following insertion of the SG-RSV 205 and connection of the connection voltage US:
Sensor not activated
- Output "Betätigt" (activated) (1) is off (AUS)
- Output "Störung" (fault) (2) ist on (EIN)
Sensor avtivated
- Output "Betätigt" (activated) (1) is on (EIN)
- Output "Störung" (fault) (2) ist on (EIN)
Cable disconnection or interruption in connection voltage
- Output "Betätigt" (activated) (1) is off (AUS)
- Output "Störung" (fault) (2) ist off (AUS)
Other functions available on request.
Subject to technical modifications.