PRODUCT DESCRIPTION
The heated holding cabinet features Marshall’s own ThermoGlo™ heating technology. Heat radiates from every square inch of the upper and lower flat plate heating surfaces. This eliminates the need to clean intricate calrod, wire and reflector assemblies.
The cabinet can accommodate up to two 1/3 size pans
2 ½” deep per deck.
The cabinet features a time and temperature control as well as an on/off switch for each deck. This allows the user to run only the deck(s) of the cabinet needed to support the level of business during each part of the day or day of the week. Each pan has an associated three-digit display for the time and two LED indicator lights to the left and right of the time display. The LED will direct the operator which pans should be used first by displaying a green light while the back-up pan LED will display a red light.
Supplier Name: |
MARSHALL AIR SYSTEMS, INC. |
Address: |
419 Peachtree Drive South |
|
Charlotte, NC 28217 |
Model #: |
______________________ |
Serial #: |
______________________ |
Date Received: |
______________________ |
Date Installed: |
______________________ |
Telephone #: |
704-525-6230 |
Fax #: |
704-525-6229 |
Service Referral #: |
800-722-3474 |
Local Service Name: _____________________ |
|
|
_____________________ |
|
_____________________ |
Local Service #: |
_____________________ |
GENERAL SPECIFICATIONS
Height: |
19.750” |
Width |
15.375” |
Depth: |
15.625” |
Weight: |
70 lbs |
# of Deck: |
3 |
# Pans per Deck: |
2 |
Electrical: |
120V/9A |
Cord: |
36” Long w/ NEMA 5-15 plug |
Approvals: |
NSF, ETL/CETL |
Patent Pending
169178 RV020216
Copyright © 2016 Marshall Air Systems, Inc.
All Rights Reserved.
OWNER’S MANUAL
MODEL DH5F-333ARB – HEATED HOLDING CABINET
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE
AVERTISSEMENT
Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil, ni de tout autre appareil.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
AVERTISSEMENT: Une installation, un ajustement, une altération, un service ou un entretien non conforme aux normes peut causer des dommages à la propriété, des blessures ou la mort.
Lisez attentivement les directives d’installation et d’opération et d’entretien avant de faire l’installation ou l’entretien de cet équipement
KEEP THIS MANUAL IN A SAFE PLACE AND RETAIN FOR FUTURE USE.
Cabinet area must be kept free of combustible materials and the flow of ventilation air must not be obstructed. Operating personnel must not perform any maintenance or repair functions. Contact your Qualified Service Company.
Clean cabinet including shelves and base with a damp cloth/rag and a mild cleaner.
DO NOT USE A GREEN SCOTCH BRITE PAD OR ANY OTHER ABRASIVE CLEANING PAD. THE BLUE SCOTCH BRITE (NO SCRATCH) IS SAFE TO USE.
DO NOT USE CAUSTIC CLEANING SOLUTIONS SUCH AS OVEN CLEANER. USE ONLY MILD, NON-ABRASIVE CLEANER.
DO NOT IMMERSE IN WATER!
169178 RV020216
Copyright © 2016 Marshall Air Systems, Inc.
All Rights Reserved.
OWNER’S MANUAL |
|
MODEL DH5F-333ARB – HEATED HOLDING CABINET |
|
TABLE OF CONTENTS |
|
PRE-INSTALLATION..................................................................................................................... |
1 |
FINAL INSTALLATION ................................................................................................................... |
1 |
OPERATION ................................................................................................................................ |
1-2 |
PROGRAMMING ............................................................................................................................ |
3 |
DEFAULT PRESET VALUES......................................................................................................... |
4 |
DAILY MAINTENANCE .................................................................................................................. |
4 |
MONTHLY MAINTENANCE ........................................................................................................... |
5 |
TROUBLESHOOTING................................................................................................................. |
6-8 |
REPLACEMENT PARTS ........................................................................................................... |
9-10 |
|
ILLUSTRATIONS |
OVERALL DIMENSIONS DH5F-333ARB |
........................................................................FIGURE 1 |
REPLACEMENT PARTS DH5F-333ARB ........................................................................ |
FIGURE 2 |
SCHEMATICS
WIRING SCHEMATIC, DH5F-333ARB.............................................................................. |
#169175 |
169178 RV020216
Copyright © 2016 Marshall Air Systems, Inc.
All Rights Reserved.
OWNER’S MANUAL
MODEL DH5F-333ARB – HEATED HOLDING CABINET
PRE-INSTALLATION
1.The cabinet is packaged to minimize the risk of shipping damage. Immediately upon receipt, make certain to inspect the cabinet for damage. FILE ALL CLAIMS WITH THE FREIGHT
CARRIER.
2.Unpack and inspect the cabinet. IF ANY CONCEALED DAMAGE, FILE ALL CLAIMS WITH
THE FREIGHT CARRIER.
FINAL INSTALLATION
1.Unpack cabinet and remove all protective paper or plastic covering from metal parts.
2.If applicable, make sure that the back air circulator plenum is well latched in place and plugged in to the cabinet(s). (See photos on page 7.)
3.Place cabinet in the stable base.
4.Plug cabinet into 120v receptacle rated for 15 amps.
5.Installation shall comply with the latest version of the National Electrical Code, NFPA 70.
6.Wash and sanitize all parts before placing them in the cabinet.
OPERATION
Left Channel Display |
Left channel |
Right Channel Display |
Temperature button |
The following is the user interface layout for each deck. |
|
timer start/stop |
Right channel |
|
timer start/stop |
||
button |
||
button |
||
|
Up &
Down
Arrow
Buttons
LED Indicator Lights |
LED Indicator Lights |
On/Off |
Left Channel |
Right Channel |
Switch |
|
|
|
CONTROLLER POWER UP:
1.Upon power up, the controller will briefly show the software version and then go to preheat mode and the display will show "PHt"
169178 RV020216 1
Copyright © 2016 Marshall Air Systems, Inc.
All Rights Reserved.
OWNER’S MANUAL
MODEL DH5F-333ARB – HEATED HOLDING CABINET
PREHEAT:
1.The controller will stay in preheat mode ("PHt") for the entire preheat period (preheat time parameter) even though both heaters (top and bottom) have reached set points before the end of that period. If the controller is inadvertently turned OFF and back ON, the preheat period can be bypassed by a 3 second press of the down arrow button only if both heaters are within the allowed differential temperature set points (preheat bypass temperature parameter).
2.After preheat, the controller goes into idle mode "---". At this time, any timer can be started.
HOLDING TIME CYCLES:
1.To start a cycle, press a timer start/stop button. The display will show the holding time value in minutes and starts the countdown. The LED bars for that timer channel will then light steady green.
2.When the timer reaches the pre-alert value, the display will then alternate between showing the remaining time and "drP" for DROP, the LED bars will start flashing and a beeping will start. The user then has to acknowledge the pre-alert by a press of the timer start/stop button. The display will then flash the remaining time for the rest of the cycle, the LED bars will go back to steady and the beeping will stop.
3.When the timer reaches the "000" value, the display will flash "000", the LED bars will flash red and the beeping will start until the user acknowledges the end of the cycle by pressing the timer start/stop button. The timer will then go back to idle mode "---", the led bars will turn OFF and the beeping will stop.
4.Any holding cycle can be cancel at any time by a 3 second press of the timer start/stop button.
5.If at any time during normal operation, one heater’s temperature is falling or rising out of the allowed differential from set point (ready mode differential parameter), the displays will alternate between current mode and "LO" or "HI" to alert the user that the heater’s temperature is too low or too hi. This should remain until the heaters are back within the allowed differential.
CURRENT TEMPERATURES DISPLAY:
1.To view the heaters current temperature, press and hold the temperature button for 3 seconds. The display will then alternate between "toP" for top heater and its current temperature value.
2.To view the bottom heater current temperature, press the temperature button again. The display will then alternate between "bot" for bottom heater and its current temperature value.
3.A press of the temperature button will cycle between top and bottom current temperatures.
4.To exit temperature view mode and return to previous mode, press and hold the temperature button.
169178 RV020216 2
Copyright © 2016 Marshall Air Systems, Inc.
All Rights Reserved.