• To prevent short circuits, this product should only be used inside and only in dry
spaces. Do not expose the components to rain or moisture. Do not use the product
close to a bath, swimming pool etc.
• Do not expose the components of your systems to extremely high temperatures or
bright light sources.
• In case of improper usage or if you have altered and repaired the product yourself,
all guarantees expire. Marmitek does not accept responsibility in the case of improper
usage of the product or when the product is used for purposes other than specified.
Marmitek does not accept responsibility for additional damage other than covered by
the legal product responsibility.
• This product is not a toy. Keep out of reach of children.
• Do not open the product (battery panel excepted): the device may contain live parts.
The product should only be repaired or serviced by a qualified expert.
• Keep batteries out of the reach of children. Dispose of batteries as chemical waste.
Never use old and new batteries or different types of batteries together. Remove the
batteries when you are not using the system for a longer period of time. Check the
polarity (+/-) of the batteries when inserting them in the product. Wrong positioning
can cause an explosion.
• Only connect the adapter to the mains after checking whether the mains voltage is
the same as the values on the identification tags. Never connect an adapter or power
cord when it is damaged. In that case, contact your supplier.
• Automatic switching devices provide comfort, but can also be dangerous. They can
surprise people or can ignite clothing hanging over an electric heat source. Please be
careful and take appropriate measures to avoid accidents.
Marmitek X-10 components use the existing mains wiring to communicate (using
Marmitek X-10 signals). You can build a complete system using the three different
kind of components of the Marmitek X-10 System:
1. Modules:These components will receive Marmitek X-10 signals and will
switch or dim the attached lamp or appliance. Examples of these modules are lamp
modules and appliance modules. These are available as build-in, micro, DIN rail and
plug-in modules.
2. Controllers: These components will transmit Marmitek X-10 signals and
thus will control the Modules.
3. Transmitters: Wireless components like remotes. The signals of these
components will be received by a controller with transceiver functionality (IRRF 7243,
TM13 or CM15Pro). The Transceiver will translate the signals into Marmitek X-10
signals on the power line.
ADRESSES
Up to a maximum of 256 different addresses can be preset. These are subdivided into
a so-called HouseCode (A to P incl.) and a UnitCode (1 to 16 incl.). The HouseCode
can also be set on the controllers, so that the controllers and modules become part of
the same system. The address can be set either using code dials or by pressing
buttons, depending on the type of module.
The Marmitek X-10 System uses standard commands, which control all units with the
same HouseCode at the same time (e.g. all lights on, all off, etc.).
SIGNAL RANGE
ENGLISH
Range of Marmitek X-10 signals over the Power Line and how to increase the
range.
The Marmitek X-10 System is based on power line communication. The range of the
Marmitek X-10 signals very much depends on the local circumstances. On average the
range is a cable length of 80 meters.
MT20™
5
If you have difficulties with the range of your Marmitek X-10 signals, please
pay attention to the following facts:
1. When more than one phase is used for your electrical system, it is necessary to
couple these phases for the Marmitek X-10 signals. For coupling you can use FD10
Phase Couplers/Filters. You only need to install a Phase Coupler/Filter when your wall
outlets and light switches are divided over more than one phase (more than one
group is no problem). For bigger buildings or longer distances we advice you to use an
active repeater instead of passive FD10’s.
2. It is possible that Marmitek X-10 signals are attenuated by devices and lights which
are connected to the power line. In a normal home situation this effect is negligible
(the Marmitek X-10 system is using active gain control to eliminate the effects).
However, it is possible that a particular device in your house is attenuating the signals
so much that the range of Marmitek X-10 signals is decreased significantly. When you
have range problems, it is wise to try to locate the device which is attenuating the
signals simply by unplugging devices from the power line, and testing the differences
in range for your Marmitek system. When e.g. your conclusion is that e.g. your
computer monitor is attenuating the signal, you can use a FM10 Plug-in Filter
between the power line and the monitor to eliminate the effects.
Known devices which can cause attenuation are:
PC Monitors
PCs with heavy internal power supplies
Old Televisions
Copiers
Fluorescent Lights
Gas Discharge Lamps (Energy Saving Lamps)
3. Some (old) devices are able to disturb the signal by transmitting noise on the power
line. Because the Marmitek X-10 signals are transmitted on 120 kHz, only noise on or
near this frequency will have influence on the range. When you use a FM10 Filter to
connect this device to the power line, the noise will be filtered.
4. The Marmitek X-10 protocol has several mechanism to avoid modules to be
switched on or off by other sources than your Marmitek X-10 Controllers. However, it
is possible that the Marmitek X-10 signals are disturbed by e.g. baby phones which
are in TALK mode (continuous transmission). When these kind of signals are present
on the power line it is possible that the Marmitek X-10 signals will not come through.
5. The mains do not stop at the front door of your home. Everything that is attached
to mains nearby your home can have influence on Marmitek X-10 signals (e.g. heavy
machinery). If you think that your system is influenced by devices out of your house, it
is advisable to install FD10 Phase Coupler/Filter on each phase entering the house.
These filters will block signals coming into or going out of your house, but will also
match the impedance for the mains. Hereby make your house Marmitek X-10
compatible for these units. The FD10’s will not only filter but will also couple the
phases (please see 1).
ENGLISH
MT20™
7
INTRODUCTION
The Marmitek X-10 Mini Timer controls up to 8 X-10 Modules automatically or
instantly. You can have your outside lights as well as inside lights and appliances go
on and off at preset times to give your home a lived-in look while you are away.
You can program your Modules to go on and off at the same time every day or you
can set your radio to wake you up “Once” only, for an early morning flight. There is
even a “Security” Mode that automatically varies your programmed time each day so
your home doesn’t look like it’s controlled by a timer.
You can keep the Mini Timer by your bedside and it will wake you up on weekdays. It
has a snooze feature so you can sleep a while longer and you can turn the alarm off
on weekends.
You can manually turn off your child’s radio or night light from your bedside. You can
turn on ALL lights connected to Lamp Modules with the touch of a button if you hear
a suspicious noise at night. You can even turn off everything in the system with one
button.
BEFORE YOU BEGIN
Keep in mind that your Marmitek X-10 System will always turn lamps and appliances
on or off the instant you press the buttons. That’s obvious - but there can be some
unexpected consequences.
For example, an empty coffee pot can be remotely turned on. If that should happen,
your coffee pot may be damaged from overheating. If an electric heater is turned on
by remote control while clothing just happens to be draped over it, a fire could result.
Therefore, do not use with high power heating devices such as portable heaters.
Always be aware of what appliance you are turning on or off so that potentially
dangerous situations will not occur.
WHAT IT DOES
The Marmitek Mini Timer plugs into any AC outlet in your home and you set it like a
digital alarm clock. Channel number 1 also activates an internal buzzer so you can use
it as an alarm clock too! You can program up to 8 X-10 Modules from the Mini Timer
and you also have instant control of 8 Modules.
There is a handy snooze feature which lets you cancel the alarm buzzer by pressing
any key. This will stop the buzzer and will set the alarm off again in 10 minutes. You
can do this indefinitely.
Advancing to a particular time (in the Prog Set/Review mode) and then pressing a
number ON or OFF key will set an on or off time for that Module, every day. However,
if (within 4 seconds) you press “Once” you will change that program to occur only
once, if you press “security” you will change the program to occur at different times
each day (variably).
The Mini Timer plugs into any AC outlet in your home and transmits digitally encoded
signals over your house wiring instantly or at the times you set. These signals are
received by the X-10 Modules.
You Plug a lamp up to 300 watts into a Lamp Module, an appliance such as a radio,
fan, or coffee pot into an Appliance Module and replace important indoor or outdoor
security lights up to 3600 watts with the In Wall Appliance Module (modules sold
separately).
SETTING IT UP
Connect the power supply to the Mini Timer and plug the power supply into any
convenient AC outlet.
NOTE: you must use the power supply that came with the Mini Timer. The power
supply contains circuitry required to control your Marmitek X-10 modules, so you
CANNOT replace it with a regular 12V power supply.
Install two AA alkaline batteries in the compartment on the back, if desired (to protect
the time and programmed events if there's a power outage).
ENGLISH
MT20™
9
QUICK TOUR
Let’s quickly review the functions of each part of the keyboard (you can go to
SETTING UP THE MINI TIMER for a step by step tutorial if you prefer). Referring to the
diagram below and the cutaway sections that follow, you will see that the keyboard
on the Mini Timer consists of 7 basic areas.
1. Mode Switch. This is used to select whether you want to set or
review a timed event, change the Housecode, or set the clock. See
Changing the Housecode to change the Housecode.
2. ON/OFF Buttons. There are 4 sets of ON/OFF
buttons. They let you turn Modules 1 through 4
(or 5 through 8) on and off instantly by pressing
either the ON or OFF button.
In the “Prog Set/Review” mode these button are
used to set on and off times for the selected
number (1 to 4 or 5 to 8).
3. Time/dim Adjust Rocker. This is used to set the time of the clock and
the time you want to set for each programmed event. Also brightens/dims
Lamp and Wall Switch Modules, after selecting desired number button.
4. Alarm. The number 1 button also sets the time for the internal alarm
buzzer.
5. All Units Off Button. Instantly turns Off ALL Modules including Appliance
Modules.
6. Mode Button cycles through Daily, Once, and Security Modes.
10
7. All Lights On Button. Instantly turns on ALL Lamp/dimmer Modules.
How to program a timed event
1. Place the mode switch in “Prog Set/Review” position.
2. Advance to the desired time.
3. Set the 1-4/5-8 switch to the desired position.
4. Press any of the 4 ON or OFF buttons to set an On or Off time for that Module. This
will program the Mini Timer to turn that Module on (or off) at that time every day.
5. Advance to another time, and press another ON or OFF button as desired.
6. Set the Mode switch back to RUN.
Special programming buttons
1. Mode button. If within 4 seconds after setting an On or Off time, you press the
shown in the display, to modify the program so that your lights (or appliances) will go
on or off at a slightly different time every day (within the programmed hour). With
each press the display shows whether you've selected Once, or Security. If neither
Once nor Security is displayed, the event happens at the same time ev
2. Clear Button. Pressing this (in the Prog/Review Mode) cancels the On time or Off
3. Wakeup Switch. In the “ON” position an internal wake up buzzer will sound at
4. Selector Switch. Used to select whether you want your Mini Timer to instantly
“Mode” button once or twice until Once shows in the display, you will
modify the program to carry out your programmed event only Once and it
will not repeat on the next day.
Press again (within 4 seconds after setting an On or Off time) until Security is
ery day.
time being displayed.
the time programmed for Module number 1. When this sounds you can turn
it off by pressing any button to obtain the “snooze” feature. This will turn
the buzzer back on in 10 minutes and will do so each time you operate
snooze.
The alarm can be cancelled by moving the Buzzer switch to “OFF” and back
to “ON” (for wake up the next mo
control Modules set to Unit Codes 1 thru 4 or 5 thru 8. You can move the
selector switch back and forth to achieve instant control of 8 X-10 Modules.
You can also move the switch during programming to select which modules
(1-4 or 5-8) you are setting times for.
rning).
ENGLISH
MT20™
11
SETTING UP THE MINI TIMER
Setting the clock
Plug the Mini Timer into any convenient AC outlet. Fit two AA alkaline batteries in the
battery compartment to protect the time and program for up to 48 hours in the event
of a power outage. If the battery is low, dead, or not installed, the low battery
indicator will show in the display.
When you first plug in the Mini Timer the display will flash. It will also flash if you have
had a power outage and have not installed two AA alkaline batteries or if the
batteries are dead.
2. Press the top of the “Time” rocker to advance to the correct time. A
quick press on the rocker will advance the time by 1 minute. If you hold the
rocker down the display will advance to the correct time faster. If you
overshoot, you can use the bottom rocker to go back.
Controlling x-10 modules
Follow the steps below to make sure you can control your Modules before you
program the Mini Timer.
1. Install and set up all of your Marmitek X-10 Modules referring to the instructions
included with them. Be sure to turn off the power at the main circuit breaker
panel when installing Wall Switch Modules or Micromodules.
2. Set all of your Modules to the same Housecode as the Mini Timer (default is A).
3. Set each Module to a Unit Code Between 1 and 8.
4. Set the Mode Switch on the Mini Timer to the “RUN” position.
5. To turn On a particular Module, set the selector switch to 1-4 or 5-8, then press the
ON button corresponding to the number you set on the Module you want to control.
Then press and hold Bright or Dim to brighten or dim the light (Lamp/dimmer
Modules only).
6. To turn Off a particular Module, set the selector switch to 1-4 or 5-8, then press
the OFF button corresponding to the number you set on the Module you want to
control. The display shows On or Off next to the module number for the button you
pressed.
To turn on ALL lights connected to Lamp Modules and Wall Switch Modules (with
the same Housecode as the Mini Timer), press the “All Lights On” button. This does
not affect appliances.
To turn off ALL lights AND appliances connected to any kind of X-10 Module
(with the same Housecode as the Mini Timer), including Appliance Modules, press the
“All Off” button.
Setting something to happen every day at the same time
After you have installed all of your Modules and checked that they are working
instantly from the Mini Timer you are ready to program timed events.
2. Set the 1-4/5-8 switch as desired.
3. Press the “Time” advance rocker key to advance to the desired on or off time.
For example: If you advance to 12:45 PM and then press the ON button for number 2,
you will program the Module set to Unit Code 2 to go On at 12:45 PM every day.
If you advance to 7:00 AM and then press the OFF button for number 2, you will
program the Module set to Unit Code 2 to go Off at 7:00 AM every day.
You can now advance to another time and press another ON or OFF button (or the
same button) to program another time.
NOTE:
You can program a total of 64 On or Off times. These are distributed between the 8
unit codes (selected with the 4 ON/OFF buttons). You could for example program
Module number 1 to go On 32 times and Off 32 times, but then that would use up all
the memory and you wouldn't be able to program any times for any of the other 7
unit codes. Or, you could program modules 1 thru 8 to go On and Off 4 times each.
I.E. you could program 4 On and Off times for modules 1 thru 4, then slide the
selector switch to the 5-8 position and program another 4 On and Off times for
modules 5 thru 8.
1. Set the Mode Switch to the “Prog Set/Review” position.
When you first press the rocker the time will advance by 1 minute. If you
hold the top of the rocker down the display will “speed up” so you can get
to the desired time faster. When you get close to the desired time, you can
“tap” the rocker a few times to get to the exact time you want. If you
overshoot, you can press the bottom of the rocker to go back.
4. When you reach the desired time press the ON or OFF button for the Unit
Code you want to program an On or Off
time for.
ENGLISH
MT20™
13
If you try to set an on or off time and the memory is full, the display will read FULL. To
clear this, press the Clear button.
Setting a timed event to occur Once only
If (within 4 seconds after setting an On or Off time) you press the “Mode” button
once or twice until Once shows in the display, you will modify the program for that
particular Unit Code to occur only Once.
The event you have programmed will happen (at the time you have programmed)
within the next 24 hours, and will then be automatically cleared from memory and
will not happen again the next day.
You can mix Once and Daily events for the same Unit Code (up to the 64 maximum
events for all 8 unit codes).
Setting a timed event to occur in the “Security” mode
If you advance to a specific time, and then press one of the ON or OFF buttons, you
will set an On or Off time for that Unit Code to occur every day at exactly the same time.
If however, within 4 seconds after setting an On or Off time, you press the “Mode”
button once or twice until Security is shown in the display, you will modify the
program for that particular Unit Code to occur every day at a slightly different time
each day.
The event you have programmed will happen at the time you have programmed on
the first day, and will then happen at a different time on each subsequent day (within
the hour you have programmed). For example:
If you advance to 7:35 PM, press the ON button for number 2 and then (within 4
seconds) press the Mode button once or twice until Security shows in the display, the
Module(s) set to Unit Code number 2 will go On at exactly 7:35 PM on the first day
and any time between 7:00 PM and 8:00 PM every day after that. This time will vary
each day so that the Module doesn’t go on at the same time each day (to give your
home a lived-in look).
You can mix Once, Daily, and Security events for the same Unit Code (up to the 64
maximum events for all 8 unit codes). See note at bottom of Setting something to
happen every day at the same time
Reviewing timer events
Set the Mode Switch in the “Prog Set/Review” position. If no
events exist in memory 0:00 is displayed, otherwise the first event
found in memory is displayed.
buttons is pressed without modifying the current time, and no events are in
memory for that module, 0:00 is displayed.
14
If (while in Prog/Review Mode) one of the 4 module ON (or OFF)
If (while in Prog/Review Mode) one of the 4 module ON (or OFF) buttons is pressed
without modifying the current time, and events do exist, each press of the module
ON (or OFF) button cycles through (and displays) all the ON (or OFF) events for that
particular module. I.E. you are "Reviewing" the times that are set. The display also
shows whether the event is a Once event or a Security event. Note if it's a Security
event the actual time that the next event will occur will be shown. If neither Once nor
Security is displayed, the event is a Daily event.
If (while in Prog/Review Mode) one of the 4 module ON (or OFF) buttons is pressed
after modifying the current time, then the time is stored as a new event for that
module. I.E. you can program new events while reviewing the current programmed
events.
While displaying any time for any module it can be deleted using the Clear key. All
events for a module can be cleared by pressing Clear multiple times until the display
shows 0:00.
If an event time is modified and you do not want to store it to any module ON/OFF
button, press Clear. The previous event is now displayed and can be deleted if desired
by pressing Clear again.
If the Mode switch is moved after a time has been changed and without a module
ON/OFF button being pressed, this time is discarded and is not stored in memory.
If the display shows FULL
If FULL is displayed when you try to enter a programmed time, this means that you
have tried to enter an additional time when you have already used up all the available
memory. Cancel one or more of your set times by pressing a number ON (or OFF)
button, then press Clear to clear that event. Then enter another timer event.
Selector switch
1-4 position - With the “Selector” switch in the 1-4 position the 4 ON and
OFF buttons control (and set times for) Modules set to Unit Codes 1 thru 4
respectively.
5-8 position - With the “Selector” switch in the 5-8 position the 4 ON and
OFF buttons control (and set times for) Modules set to Unit Codes 5 thru 8
respectively.
ENGLISH
Instantly Controlling Modules
With the Mode switch in the RUN position you can slide the Selector Switch back and
forth to instantly control Modules set to 1 thru 4, or 5 thru 8. Also, in the Prog
Set/Review mode you can set events for modules 1 thru 4, then move the selector
switch and program more events for modules 5 thru 8. See note at Setting something
to happen every day at the same time for maximum number of events you can
program..
MT20™
15
Setting the Alarm Buzzer
With the “Wake” switch in the “ON” position, any program you set for
Module number 1 will also set the internal alarm buzzer.
A bell icon will show in the display to indicate that a time for the Buzzer is
set.
For example: If you connect your bedside lamp to a Lamp Module set to Unit
Code 1 and then program Module number 1 for an On time of 7:00 AM - A
7:00 AM your bedside lamp will turn on and the internal buzzer in the Mini Timer
sound. You can turn the buzzer off (when you wake up) by sliding the Buzzer switch
to the OFF position. You can turn off your bedside lamp by pressing the OFF button
for Module 1. You can leave the Buzzer switch in the OFF position if you don’t want
to use the wake up feature. This will not affect any programs you have entered for
Module 1.
Alternatively, if the Buzzer switch is OFF and you place the Mode switch in the Clock
Set position, you will “suspend” both the buzzer AND any times you have set for
Module 1. This is useful to suspend the wake-up function on weekends. See To Cancel/Snooze the wake-up alarm.
The backlight and the buzzer do not operate when the unit is running on the
backup batteries.
To Cancel/Snooze the wake-up alarm
When the alarm sounds at the time you have set, you can cancel it in one of two
ways:
1. Slide the Wake switch to the OFF position. This will cancel the alarm
permanently. Slide the switch back to “ON” if you want the alarm to wake you up the
next morning.
2. Press any key. This will give the “snooze” feature. Pressing any key while the
buzzer is sounding will turn the buzzer off and will automatically turn it back on in 10
minutes time. You can do this indefinitely.
The buzzer will automatically turn off, and stay off, after 10 minutes if you ignore it.
Any Module(s) you have installed and set to Unit Code 1 will turn On when the buzzer
sounds and will stay On after you turn the Buzzer switch to OFF or cancel buzzer
using the snooze feature. You will need to press the OFF button for number 1 to turn
the Module(s) off. Alternatively, you could program it/them to turn off later.
will
t
Suspending the wake up function
If you set channel 1 for an On time of 7:00 AM and number 1 is your bedside lamp, at
7:00 AM every day, your bedside lamp will turn on and the internal buzzer will
sound. If you turn the Buzzer switch off on Friday nights the buzzer will not wake you
up the next morning but your bedside lamp will still turn on.
To suspend the program for channel 1 turn the Buzzer switch to OFF, AND place
the Mode switch in the “Clock Set” position. The On program for BOTH the Alarm
buzzer AND the bedside lamp will then be suspended.
You can control Modules instantly with the Mode switch in the “Clock Set” position,
just as you can when it's in the RUN position, but remember to place the Mode switch
back to RUN and put the Buzzer switch back to the ON position on Sunday night to
resume the wake-up program for weekdays.
Note: Pressing the ON button for Module number 1 with the Mode switch in the RUN
position or Clock Set position does not activate the internal buzzer. This buzzer only
sounds at the times you set.
CHANGING THE HOUSECODE
When you first plug in the Mini Timer it controls X-10 Modules set to Housecode A.. If
you want to change the Housecode:
2. Press the up or down "Time" rocker to select the desired Housecode (as
shown in the display).
3. Set the Mode switch back to RUN.
1. Set the Mode switch to “Housecode Set.”
ENGLISH
MT20™
17
FREQUENTLY ASKED QUESTIONS
What is the reason for modules to switch on/off spontaneously?
It is possible that a Marmitek X-10 System is installed at one of your neighbours using
the same House Code. To solve this problem try to change the House Code of your
system, or have FD10 Phase Coupler/Filter installed at your incoming mains.
My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same
House Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or
Marmitek X-10 Security Console installed in your house. These components will
translate the radio signals to the Marmitek X-10 signal on the power line. Using
several remotes and sensors, you only need one central transceiver.
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of
your remotes is not sufficient. The TM13 is using so called collision detection to
prevent signals to be disturbed when more than one TM13 is transmitting. TM13’s
will wait for a quite power line before transmitting their data. To prevent your
Marmitek X-10 System to become slow or to prevent dimming from becoming less
smooth, make sure that the TM13 units are placed as far away from each other as
possible.
a Particular Module won’t go on or off from the buttons on the Mini Timer:
Check that you have power to the outlet controlling the Module and the switch on
the light or appliance is ON.
Check that the Unit Code and Housecode on the Module are set correctly. Try
plugging the Module and the Mini Timer into the same outlet. If the Module doesn’t
work in ANY outlet, not even with the Module and the Mini Timer in the same duplex
receptacle (top and bottom) the Module may be defective.
You can’t control ANY Modules from the Mini Timer.
Check that there is a time displayed on the Mini Timer and that you have power to
the outlet it is plugged into.
Check that the Housecode for the Mini Timer is set correctly (see Changing the Housecode). Try plugging the Module and the Mini Timer into the same outlet. If
NONE of your Modules work in ANY outlet, not even with the Module and the Mini
Timer in the same duplex receptacle (top and bottom) the Mini Timer may be
defective
Intercom systems
Intercom systems which send voice signals over existing electrical wiring may interfere
with the operation of the Mini Timer when the intercom is in use. If the Intercom
system has its own separate wiring it will not cause a problem.
Power interruptions
When the power is restored after an outage, Lamp Modules and Wall Switch Modules
will normally be OFF. Appliance Modules have a “latching relay mechanism” and will
stay as they were before the interruption.
This means that when you first plug in an Appliance Module which you have just
purchased, it may in an ON or OFF state (the state it was in before unplugging it after
factory testing).
Battery backup
If you install two AA alkaline batteries in the battery compartment of the Mini Timer
your programmed times will be protected for up to 48 hours in the event of a power
outage. The backlight and the buzzer do not operate when the unit is running on the
backup batteries.
Battery indicator
If the batteries are low, dead, or not installed, the low battery indicator will be shown
in the display. It is recommended that you check the condition of the batteries
regularly and replace them at least once every 6 months.
ENGLISH
Do you still have questions? Please check out www.marmitek.com for more
information.
MT20™
19
TECHNICAL SPECIFICATIONS
MT20:
Backup battery: 2 x AA batteries.
Dimensions: 121 x 56 x 86 mm
Weight: 200 g
Colour: Silver
PS90:
Power: 230V +10% -15 %, 50 Hz
Supply current : < 4,5W
Signal transmission: > 5Vpp in 5 Ohm at 120 kHz ± 1 kHz
X-10 transmission: 1 pulse burst at 0°, 60° and 120°
Sends X-10 Key codes: On, Off, DIM+, DIM-, All Units OFF, All Lights ON.
Ambient temperature: - -10° C to + 50° C (operation)
-20° C to + 70° C (storage)
Environmental Information for Customers in the European Union
European Directive 2002/96/EC requires that the equipment bearing this
symbol on the product and/or its packaging must not be disposed of with
be disposed of separately from regular household waste streams. It is your
responsibility to dispose of this and other electric and electronic equipment via
designated collection facilities appointed by the government or local authorities.
Correct disposal and recycling will help prevent potential negative consequences to
the environment and human health. For more detailed information about the disposal
of your old equipment, please contact your local authorities, waste disposal service, or
the shop where you purchased the product.
20
unsorted municipal waste. The symbol indicates that this product should
• Um Kurzschluss vorzubeugen, dieses Produkt bitte ausschließlich innerhalb des
Hauses und nur in trockenen Räumen nutzen. Setzen Sie die Komponenten nicht
Regen oder Feuchtigkeit aus. Nicht neben oder nahe eines Bades, Schwimmbades
usw. verwenden.
• Setzen Sie die Komponente Ihres Systems nicht extrem hohen Temperaturen oder
starken Lichtquellen aus.
• Bei einer zweckwidrigen Verwendung, selbst angebrachten Veränderungen oder
selbst ausgeführten Reparaturen verfallen alle Garantiebestimmungen. Marmitek
übernimmt bei einer falschen Verwendung des Produkts oder bei einer anderen
Verwendung des Produktes als für den vorgesehenen Zweck keinerlei Produkthaftung.
Marmitek übernimmt für Folgeschäden keine andere Haftung als die gesetzliche
Produkthaftung.
• Dieses Produkt ist kein Spielzeug. Außer Reichweite von Kindern halten.
• Das Produkt niemals öffnen (ausgen.des Batteriefachs): Das Gerät kann Teile
enthalten, worauf lebensgefährliche Stromspannung steht. Überlassen Sie
Reparaturen oder Wartung nur Fachleuten.
• Halten Sie die Batterien außerhalb der Reichweite von Kindern. Liefern Sie die
Batterien als chemischen Kleinabfall ein. Verwenden Sie niemals alte und neue oder
unterschiedliche Typen von Batterien durcheinander. Wenn Sie das System längere
Zeit nicht benutzen, entfernen Sie die Batterien. Achten Sie beim Einlegen der
Batterien auf die Polarität (+ / -): Ein falsches Einlegen kann zu Explosionsgefahr
führen.
• Schließen Sie den Netzadapter erst dann an das Stromnetz an, nachdem Sie
überprüft haben, ob die Netzspannung mit dem auf dem Typenschild angegeben
Wert übereinstimmt. Schließen Sie niemals einen Netzadapter oder ein Netzkabel an,
wenn diese beschädigt sind. In diesem Fall nehmen Sie Kontakt mit Ihrem Lieferanten
auf.
• Automatisches Schalten ist nicht nur bequem, sondern kann auch Gefahr bedeuten.
So können Personen überrascht werden, oder kann Kleidung, die über eine elektrische
Wärmequelle hängt in Brand geraten. Passen Sie immer auf und treffen Sie
Maßnahmen um dies zu verhindern.
Die Komponenten aus dem Marmitek X-10 Sortiment kommunizieren mit einander
über das bestehende Lichtnetz (mittels Marmitek X-10 Signalen). Das Sortiment
besteht aus drei Teilen:
1. Module:Diese empfangen die Marmitek X-10 Signale und schalten oder
dimmen die angeschlossene Belastung. Modulbeispiele sind die Lampen- und
Gerätemodule. Diese sind in den Modellen Einbau, Mikro, Din-Rail und Steckanschluss
erhältlich.
2. Empfänger:Diese senden die Marmitek X-10 Signale und steuern somit die
Module.
3. Sender:Dies sind drahtlose Komponenten wie z.B. Fernbedienungen. Die
Signale der Sender werden von einem Empfänger mit Transceiver-funktion (IRRF 7243,
TM13 oder CM15Pro) empfangen. Die Signale werden von dem Transceiver auf das
Lichtnetz gesetzt.
ADRESSIERUNG
Sie können maximal bis zu 256 verschiedene Adressen einstellen. Diese sind
aufgegliedert in einen so genannten HausCode (A bis einschl. P) und einen UnitCode
(1 bis einschl. 16). Der HausCode kann auch an den Reglern eingestellt werden,
sodass Regler und Module zum selben System gehören werden. Die Adresse kann
mithilfe von Kodierscheiben oder durch Tastenbedienung eingestellt werden. Dies
hängt vom Modultyp ab.
Das Marmitek X-10 System beinhaltet standardmäßige Befehle, wobei alle Units
innerhalb desselben HausCodes zugleich gesteuert werden (z.B. sämtliche Lampen
einschalten, alles ausschalten usw.).
REICHWEITE VON SIGNALEN
DEUTSCH
Reichweite von Marmitek X-10 Signalen über das Lichtnetz und diese
Reichweite vergrössern.
Das Marmitek X-10 System basiert auf der Kommunikation über das bestehende
Lichtnetz. Die Reichweite von Signalen über das Lichtnetz ist sehr von der örtlichen
Situation abhängig. Ein guter Durchschnitt der Reichweite ist jedoch eine Kabellänge
von 80 Metern.
Bei Problemen mit der Reichweite von Marmitek X-10 Signalen sind folgende
Faktoren wichtig:
1. Werden mehrere Phasen im Haus verwendet, kann es notwendig sein, um diese
Phasen für Marmitek X-10 Signale zu koppeln. Dieses Koppeln kann geschehen,
MT20™
23
indem Sie einen FD10 Phasekoppler verwenden und wird benötigt, wenn Steckdosen
und Lampenanschlüsse tatsächlich über mehrere Phasen verteilt sind (mehrere
Gruppen sind kein Problem für die Marmitek X-10 Signale). Für größere Gebäude
advisieren wir die Verwendung eines aktiven 3 Phasen Verstärkers statt eines
Koppelfilters.
2. Marmitek X-10 Signale können durch Geräte und Lampen vermindert werden, die
auf das Lichtnetz angeschlossen sind. In normalen Hausanlagen ist dieser Effekt
normalerweise zu verwahrlosen (das Marmitek X-10 System verwendet u.a. eine
aktive Verstärker um diesen Effekt zu eliminieren). Doch kann es sein, dass ein
einzelnes Gerät in Ihrer Wohnung stört. Wenn Sie feststellen, dass Signale nicht
immer gut durchkommen, dann können Sie ein solches Gerät relativ einfach
aufspüren, indem Sie die Stecker der verdächtigen Geräte aus der Steckdose ziehen
und erneut einen Test durchführen. Stellen Sie fest, dass Ihr Problem gelöst ist, durch
z.B. den Stecker Ihres PC’s aus der Steckdose zu ziehen, dann können Sie das Problem
lösen, durch diesen PC-Monitor mit einem FM10 Steckerfilter zu versehen. Dieser
Steckerfilter sorgt dafür, dass die Signale nicht länger durch das betreffende Gerät
vermindert werden.
Wir empfehlen um folgende Geräte zu kontrollieren:
PC Monitore
PC’s mit relativ hoher Leistung
Alte TV-Geräte
Kopiermaschinen
Ein Raum mit vielen Neonlampen
3. Einige (alte) Geräte können Störsignale auf das Lichtnetz bringen, wodurch die
Marmitek X-10 Kommunikation gestört wird. Es handelt sich dabei um Geräte, die auf
einer Frequenz von 120 kHz stören. Diese 120 kHz werden vom Marmitek X-10
System als Sendefrequenz verwendet um digitale Information über das Lichtnetz zu
schicken. Geräte, die diese Art Signale senden, können mit einem FM10 Steckerfilter
versehen werden. Hierdurch werden Störsignale das Lichtnetz nicht mehr erreichen.
4. Durch den Aufbau der Signale können andere (Stör)quellen die Module des
Marmitek X-10 Systems niemals aktivieren oder ausschalten. Wohl kann das Signal
durch z.B. Babyüberwachungsgeräte, die dauernd im ‘Sprechmodus’ stehen, gestört
werden. Durch die Anwesendheit von diesen Signalen ist es möglich, dass das
Marmitek X-10 Signal nicht durchkommt.
5. Das Lichtnetz Ihrer Wohnung endet nicht bei der Haustüre. Alles was außerhalb (in
der Nähe) Ihrer Wohnung auf dem Lichtnetz angeschlossen ist, kann die Marmitek X10 Signale beeinflussen. Vor allem wenn Ihre Wohnung an eine Fabrikhalle mit
schweren Maschinen grenzt ist es nützlich, um einkommende Phasen mit einem FD10
Phasenfilter zu versehen. Diese Filter formen eine Blockade für alle Signale, die in Ihre
Wohnung wollen oder diese verlassen wollen, sorgen jedoch auch für eine perfekte
‘Impedanzanpassung’ des Lichtnetzes Ihrer Wohnung. Sie bereiten Ihre Wohnung auf
Marmitek X-10 vor, indem Sie diese Module plazieren. Hierdurch kuppeln Sie auch
gleichzeitig die Phasen (siehe Punkt 1).
Der Marmitek X-10 Mini Timer regelt bis zu 8 X-10 Module automatisch oder direkt.
Sie können Ihre Außen- und Innenbeleuchtung und Geräte zu voreingestellten Zeiten
ein- und ausschalten lassen, sodass Ihr Haus bewohnt erscheint, wenn Sie nicht
zuhause sind.
Sie können Ihre Module so programmieren, dass sie jeden Tag zur selben Zeit einoder ausgehen oder Ihr Radio einstellen, um Sie einmalig zu wecken, weil Sie einen
Flug früh schaffen müssen. Der Timer besitzt sogar eine Überwachungsschaltung,
welche die von Ihnen programmierten Zeiten täglich variiert, sodass Ihr Haus nicht
aussieht, als würde es von einem Timer geregelt.
Sie können den Mini Timer neben Ihrem Bett aufstellen und er wird Sie täglich
wecken. Aufgrund seiner Schlummerfunktion können Sie noch etwas länger liegen
bleiben und den Alarm an den Wochenenden ausschalten.
Sie können das Radio oder die Nachtischlampe Ihres Kindes von Ihrem eigenen Bett
aus manuell ausschalten. Sie können alle an die Lampenmodule angeschlossene
Beleuchtung mit einem Tastendruck einschalten, wenn Sie in der Nacht ein
verdächtiges Geräusch hören. Sie können sogar mit nur einem Tastendruck alle
Module des gesamten Systems abschalten.
BEVOR SIE BEGINNEN
Bedenken Sie, dass Ihr Marmitek X-10 System immer Ihre Beleuchtung und Geräte
ein- oder ausschaltet, sowie Sie auf die Tasten drücken. Das ist zwar logisch – kann
aber einige unerwartete Folgen haben.
So kann beispielsweise eine lehre Kaffeemaschine fernbedient eingeschaltet werden.
Das kann zu Beschädigungen durch Überhitzung führen. Wird eine elektrische
Heizung fernbedient eingeschaltet wenn sich zufällig Kleidung darauf befindet,
könnte ein Brand entstehen. Verwenden Sie das System deshalb nicht für starke
Wärmequellen wie tragbare Heizgeräte.
Beachten Sie immer, welche Geräte Sie ein- oder ausschalten, um potenziell
gefährliche Situationen zu vermeiden.
DEUTSCH
WAS ER TUT
Der Marmitek Mini Timer kann an jede gewünschte Wandsteckdose angeschlossen
und gleichsam wie ein Digitalwecker eingestellt werden. Kanalnummer 1 aktiviert
auch den internen Summer, sodass Sie ihn auch als Wecker nutzen können! Mit dem
Mini Timer können Sie bis zu 8 X-10 Module programmieren und diese auch direkt
regeln.
Er besitzt eine praktische Schlummerfunktion die Ihnen ermöglicht den Alarm mit
einer willkürlichen Taste abzuschalten. Somit wird der Summer verstummen und nach
MT20™
25
10 Minuten wird der Alarm erneut erklingen. Sie können diesen Vorgang unbegrenzt
wiederholen.
Einstellen auf eine bestimmte Zeit (im “Prog Set/Review” Modus) und dann bei einer
Nummer die “ON” oder “OFF” Taste drücken, wird eine tägliche Ein-/Auszeit für die
Module einstellen. Wenn Sie jedoch (innerhalb von 4 Sekunden) auf “Once“ drücken
passen Sie das Programm an, sodass dieser Befehl nur einmalig durchgeführt wird.
Drücken Sie auf "Security", so passen Sie das Programm an und wird es täglich zu
verschiedenen Zeiten durchgeführt (variabel).
Wie er funktioniert
Der Mini Timer kann an jede gewünschte Wandsteckdose in Ihrem Haus
angeschlossen werden und versendet direkt oder zu von Ihnen programmierten Zeiten
digital kodierte Signale über die Bekabelung in Ihrem Haus. Diese Signale werden von
den X-10 Modulen empfangen.
Sie schließen eine Lampe (bis 300 Watt) an das Lampenmodul an, ein Gerät wie z.B.
ein Radio, Ventilator oder Kaffeemaschine an ein Gerätemodul und versehen
wichtige Innen- oder Außenbelichtung bis zu 3600 Watt mit einem EinbauGerätemodul (Module sind separat erhältlich).
ANSCHLIEßEN
Schließen Sie die Speisung an den Mini Timer an und stecken Sie diesen in eine für Sie
geeignete Wandsteckdose.
ACHTUNG: Sie müssen die zum Mini Timer gelieferte Speisung nutzen. Die Speisung
enthält Elektronik um Ihre Marmitek X-10 Module regeln zu können, Sie können diese
also NICHT durch eine reguläre 12V Speisung ersetzen.
Legen Sie bei Bedarf zwei AA Alkaline Batterien in das entsprechende Batteriefach an
der Rückseite ein (somit bleiben die vorprogrammierten Aufgaben bei einem
Stromausfall erhalten).
KURZDARSTELLUNG
Nachstehend finden Sie eine Erläuterung der Tastatur (Sie können auch die Schritt-fürSchritt Gebrauchsanleitung EINSTELLEN DES MINI TIMERS hinzuziehen wenn Ihnen
das lieber ist). Im nachstehenden Schema und den herausgegriffenen Bestandteilen
sehen Sie, dass sich die Tastatur des Mini Timers aus 7 Basisgebieten zusammensetzt.
1. Modus Schalter. Mit diesem Schalter können Sie Befehle
einstellen oder betrachten, den Haus Code ändern oder die Uhr
einstellen. Unter Ändern des Haus Codes finden Sie, wie Sie
diesen abändern können.
2. EIN/AUS Tasten. Der Timer hat 4 Sätze mit
“ON”/”OFF” Tasten. Diese ermöglichen Ihnen
durch Drücken der "ON" oder “OFF“ Taste die
Module 1 bis 4 (oder 5 bis 8) direkt ein- und
auszuschalten.
Tasten verwendet, um die Ein- und Ausschaltzeiten für die gewählte Nummer
einzustellen (1 bis 4
oder 5 bis 8).
Im “Prog Set/Review” Modus werden diese
DEUTSCH
3. Zeit/Dimm Kippschalter. Hiermit stellen Sie die Uhrzeit und die
gewünschte Zeit für jedes Programm ein. Außerdem zum dimmen und
heller einstellen von Lampen- und Einbaumodulen, nachdem die
gewünschte Nummer gewählt wurde.
MT20™
27
4. Alarm. Mit der Ziffer 1 Taste stellen Sie auch die Zeit für den internen
Alarmsummer ein.
5. Alle Units Off Taste. Schaltet direkt ALLE Module einschl. Gerätemodule aus.
6. Mode Taste. Einstellung entweder täglich, einmalig oder Überwachungsmodus.
7. All Lights On Taste. Schaltet direkt ALLE Lampen/Dimmermodule ein.
Programmieren von befehlen
1. Schalten Sie den Modusschalter auf “Prog Set/Review”
2. Stellen Sie die gewünschte Zeit ein.
3. Schalten Sie den 1-4/5-8 Schalter auf die gewünschte Position.
4. Drücken Sie eine der 4 “ON” oder “OFF” Tasten, um Ein- oder Auszeit für dieses
Modul einzustellen. Somit wird der Mini Timer jeden Tag zur gewünschten Zeit ein
(oder aus) geschaltet werden.
5. Wiederholen Sie diese Schritte wenn Sie eine weitere Zeit programmieren möchten
indem Sie eine andere “ON” oder “OFF” Taste drücken.
6. Stellen Sie den Modusschalter in die Stellung “RUN“ zurück.
Spezielle programmiertasten
1. Modusschalter. Wenn Sie innerhalb von 4 Sekunden nach der Einstellung einer
Drücken Sie erneut (binnen 4 Sekunden nach Einstellung der Ein-/Auszeit ) bis
“Security” im Display erscheint. Nun wird das Programm so angepasst, dass Ihre
Lampen (oder Geräte) jeden Tag zu etwas anderen Zeiten an- und ausgehen (binnen
der programmierten Stunde). Bei jedem Tastendruck zeigt das Display, ob Sie “Once”
(einmalig) oder “Security” (Überwachung) gewählt haben. Werden “Once” oder
“Security “nicht wiedergegeben, so wird der Befehl täglich zur selben Zeit ausgeführt
werden.
2. Clear Taste. Mit dieser Taste (im “Prog Set/Review” Modus) wird die angegebene
Ein-/Auszeit die “Mode” Taste 1 oder 2 Mal drücken bis “Once” im Display
erscheint, wird der programmierte Befehl nur einmalig ausgeführt und am
nächsten Tag nicht wiederholt werden.
Ein-/Auszeit gelöscht.
3. Wake-up Schalter. In der “ON” Stellung wird der interne Summer zur
programmierten Zeit für das Modul Nummer 1 erklingen. Sie können den
Summer abschalten, indem Sie eine willkürliche Taste drücken, um die
Schlummerfunktion zu verwenden. Diese wird den Summer so oft Sie die
Schlummerfunktion gebrauchen jeweils nach 10 Minuten wieder einschalten.
Schalten Sie den Alarm aus, indem Sie den “Wake-up” Schalter auf “OFF”
schieben und daraufhin auf “ON” (um am nächsten Morgen wieder geweckt zu
werden).
4. Wahlschalter. Mit diesem entscheiden Sie ob Sie die Module, die auf die Unit
EINSTELLEN DES MINI TIMER
Einstellen der uhr
Schließen Sie den Mini Timer an eine geeignete Wandsteckdose an. Setzen Sie zwei
AA Alkaline Batterien ins Batteriefach ein, um die Zeit und die programmierten
Befehle im Falle eines Stromausfalls 48 Stunden lang zu bewahren. Die “Low Battery”
Anzeige im Display zeigt an, wenn die Batterien fast oder ganz verbraucht sind oder
fehlen.
Wenn Sie den Mini Timer das erste Mal anschließen, wird das Display blinken.
Dasselbe geschieht bei einem Stromausfall, wenn Sie keine AA Alkaline Batterien
eingesetzt haben oder diese fast leer sind.
Codes 1 bis 4 oder 5-8 eingestellt sind, von Ihrem Mini Timer bedienen
lassen. Sie können den Wahlschalter hin- und herschalten, um somit Ihre 8
X-10 Module direkt bedienen zu können. Sie können den Schalter während
der Programmierung auch umschalten, um auszuwählen, für welche Module
(1-4 oder 5-8) Sie die Zeiten einstelle
1. Schalten Sie den Modusschalter auf “Clock Set” .
2. Drücken Sie auf das Plus des “Time“ Kippschalters um zur richtigen Zeit
zu gehen. Ein Tastendruck auf den Kippschalter lässt die Zeit eine Minute
voraus gehen. Wenn Sie den Kippschalter gedrückt halten, verspringt das
Display schneller zur gewünschten Zeit. Wenn Sie zu weit vorausgegangen
sind, können Sie mit dem Minus wieder in der Zeit zurückgehen.
n.
DEUTSCH
Bedienen der X-10 module
Befolgen Sie nachfolgende Schritte um sicher zu gehen, dass Sie Ihre Module
bedienen können, bevor Sie den Mini Timer programmieren.
1. Installieren Sie all Ihre Marmitek X-10 Module gemäß den beigefügten
Anweisungen. Schalten Sie den Strom im Zählerschrank aus, wenn Sie die Einbau- oder Mikromodule installieren.
2. Stellen Sie alle Module auf denselben Haus Code ein wie Ihren Mini Timer
(Einstellung ab Werk ist A).
MT20™
29
3. Stellen Sie auf jedes Modul einen Unit Code zwischen 1 und 8 ein.
4. Schalten Sie den Modusschalter am Mini Timer auf “RUN”.
5. Um ein bestimmtes Modul zu aktivieren, schalten Sie den Wahlschalter auf 1-4
oder 5-8 und drücken auf die “ON” Taste, die mit der Nummer korrespondiert, die
Sie am Modul eingestellt haben, das Sie bedienen möchten. Dann drücken Sie auf
“Bright” oder “Dim” (und halten diese kurz fest) um das Licht heller oder dunkler
einzustellen (nur bei Lampen-/Dimmermodulen).
6. Um ein bestimmtes Modul auszuschalten, schalten Sie den Wahlschalter auf 1-4
oder 5-8 und drücken auf die “OFF” Taste, die mit der Nummer korrespondiert, die
Sie am Modul eingestellt haben und das Sie nun ausschalten möchten. Im Display
erscheint neben der Modulnummer “ON” oder “OFF” .
Um ALLE Beleuchtung, die an die Lampen- und Einbaumodule angeschlossen ist (mit
demselben Haus Code wie der Mini Timer), einzuschalten drücken Sie die "All Lights
On" Taste. Das wirkt sich nicht auf Geräte aus.
Um ALLE Beleuchtung UND Geräte, die an egal welche X-10 Module angeschlossen
sind, auszuschalten (mit demselben Haus Code wie der Mini Timer), einschließlich der
Gerätemodule, drücken Sie die “All Off“ Taste.
Einstellung einer täglichen und zur selben Zeit stattfindenden Tätigkeit
Nachdem Sie alle Module installiert und am Mini Timer auf Ihren Betrieb kontrolliert
haben, können Sie Befehle programmieren.
2. Schalten Sie den 1-4/5-8 Schalter in die gewünschte Position.
Zeit zurückversetzen, wenn Sie zu weit vorausgegangen sind.
4. Nachdem Sie die gewünschte Zeit eingestellt haben, drücken Sie auf die “ON” oder
“OFF” Taste für den Unit Code, in dem Sie die Ein- oder Ausschaltzeit einstellen
möchten.
1. Schalten Sie den Modusschalter auf “Prog Set/Review”
3. Drücken Sie den “Time” Kippschalter um zur gewünschten Zeit zu
gehen, zu der das Gerät sich ein- oder ausschalten soll. Einmal Drücken des
Kippschalters bedeutet, dass die Zeit eine Minute vorausgeht. Wenn Sie den
Schalter festhalten wird die Zeit schneller laufen, sodass Sie schneller bei der
gewünschten Zeit ankommen. Kurz bevor Sie die gewünschte Zeit erreicht
haben, können Sie die Taste des Kippschalters ein paar Mal “Antippen“, um
so die exakte Zeit einstellen zu können. Mit der Minus Taste können Sie die