• To prevent short circuits, this product should only be used inside and only in dry
spaces. Do not expose the components to rain or moisture. Do not use the product
close to a bath, swimming pool etc.
• Do not expose the components of your systems to extremely high temperatures
or bright light sources.
• In case of improper usage or if you have altered and repaired the product
yourself, all guarantees expire. Marmitek does not accept responsibility in the case
of improper usage of the product or when the product is used for purposes other
than specified. Marmitek does not accept responsibility for additional damage other
than covered by the legal product responsibility.
• This product is not a toy. Keep out of reach of children.
• Keep batteries out of the reach of children. Dispose of batteries as chemical
waste. Never use old and new batteries or different types of batteries together.
Remove the batteries when you are not using the system for a longer period of
time. Check the polarity (+/-) of the batteries when inserting them in the product.
Wrong positioning can cause an explosion.
• Automatic switching devices provide comfort, but can also be dangerous. They
can surprise people or can ignite clothing hanging over an electric heat source.
Please be careful and take appropriate measures to avoid accidents.
INTRODUCTION
This product is a part of the
Marmitek ProGuard800 series,
and operates together with the
ProGuard800 alarm system.
When you wish to know more
about the complete system, its
possibilities and its settings, then
you can check out the
installation manual or visit
www.marmitek.com
.
All of these sensors implement a
feature to combat the problem of
multiple transmissions, which
drastically reduce the life of the
batteries. After each transmission,
there is a four-minute delay during
which further transmissions will not
Mounting
Hole
Holder
Tamper
Switch
Switch
Vertical
Adjustment
attery
DIP-
cal
LED
Indicator
Easy
Lock
Mode
Jumper
Antenna
Pyro
Sensor
be sent.
The MS845 are designed for
Figure B.1: PIR Sensor with Cover Removed
installations prone to nuisance
alarms caused by pets or small animals.
MS845 2
Considerations Before Installation
•Select a location from which the pattern of the detector is most likely to
be crossed by a burglar, should there be a break in.
•Do not place bulky objects in front
of the detector.
•Avoid a location which comes in
direct contact with radiators,
heating/cooling ducts, mirrors and
air conditioners.
•Select an appropriate installation
height from Table B1.
Lens Mounting Height
Standard 2.2m (6.6’)
Long Range 2m (6.5’)
Curtain 1m (3.25’)
Animals
Table B.1: Recommended Mounting Height
2m (6.5’)
Pet Immunity Guidelines
It is expected that the MS845 will eliminate false alarms caused by:
• Animals up to 45kg (PI)
• Several small rodents
• Random flying birds.
The weight of the animal should only be used as a guide, other factors
such as the length and color of fur also affect the level of immunity.
For maximum pet immunity the following guidelines are recommended:
•Mount the center of the unit at a height of 2m with the PCB vertical setting
at -4.
• Set the pulse counter to 2.
• Do not aim the detector at stairways that can be climbed by an animal.
• Avoid a location where an animal can come within 1.8m of the detector
by climbing on furniture, boxes or other objects.
INSTALLATION PROCEDURE
To install PIR sensors:
1. Open the housing by removing the front cover. To do so, insert a
screwdriver in the release slot (located at the bottom of the detector
between the front and back cover). Turn the screwdriver 90º to release
the cover.
2. Remove the PCB by turning counter-clockwise and removing the Easy
Lock – do not touch the face of the pyro sensor!
3. Apply battery power by removing the isolator that separates the battery
from the contacts on the battery holder. (Note: Due to the occurrence
of voltage delay in lithium batteries that have been in storage, the
batteries may initially appear to be dead. In this case, leave the unit
in Test mode for a few minutes until the battery voltage level is
stabilized.)
4. Place the Mode jumper over pins 2 & 3 (Radio Mode); the LED flashes.
Install the Mode jumper only after applying battery power.
5. From the Programming menu, select Devices, Zones [911].
6. Select the zone to which you want to register the transmitter; the system
initiates Registration mode. When Save? appears on the panel’s LCD
display, press 9.
7. Remove the Mode jumper and place it over one pin for storage.
8. Choose an appropriate mounting height from Table B.1 and test the
transmitter from the exact mounting position before permanently
mounting the unit.
9. Knock out the mounting holes and attach the base to the wall.
10. Mount the PCB at the required vertical adjustment and replace the PCB
screw.
11. Write the number of the zone on the sticker provided. Affix the sticker
inside the front cover for future reference and replace the front cover.
Warm-Up Time
The detector will need to warm
up for the first 90 seconds after
applying power.
Pulse Counter
The pulse counter determines
the amount of beams that need
Switch 2 Switch 3 Pulse Count
OFF OFF 1
ON OFF 2
ON ON 3
OFF ON Adaptive
Table B.3: Pulse Count Setting (/MS845)
to be crossed before the
detector will generate an alarm. To set the pulse
counter, refer to table B.3.
Adaptive Pulse Count
Using the Adaptive pulse count feature, the
detector chooses between 1 or 2 pulses based on
its analysis of the received signal.
Vertical Adjustment
To position the PCB, turn the Easy Lock counterclockwise and slide the PCB up or down to the
required setting using the vertical adjustment
scale. The detector’s coverage area is 12m x 12m
when the PCB is positioned at 0. Slide the PCB up
towards the -8 position to decrease the coverage
area bringing the beams closer to the mounting
wall.
Figure B.2: Lens Coverage Diagrams
MS845 4
Walk Test Mode
A walk test is performed in order to determine the lens coverage pattern of the
detector – see Figure B.2. Walk Test mode cancels the delay time between
detections, enabling you to perform an efficient walk test.
To perform a Walk Test.
1. Place the Mode jumper over pins 1 & 2.
2. Walk across the scope of the detector according to the detection pattern
selected.
3. Confirm that the LED activates and deactivates accordingly. Wait five
seconds after each detection before continuing the test.
4. After completing the walk test, remove the jumper and place it over one
pin for storage – see Mode Jumper Safeguard.
LED Indication
The LED indicator is lit twice every time a transmission is made. To enable or
disable LED indication, refer to Table
B.4 below.
Table B.4: LED Indication Settings
The LED should only be disabled after successfully walk testing the
detector.
Mode Jumper Safeguard
During normal operation, the Mode jumper should be placed over one pin for
storage. When the mode jumper is placed over two pins, the detector is either in
Radio or Walk Test Mode. As a precaution, these modes are limited to three
minutes. After three minutes have expired, the detector switches back to normal
operation. If this happens, you can reset a mode by removing and replacing the
mode jumper.
TECHNICAL DATA
Antenna: Built-in Whip
Frequency: 868.35MHz FM
Power: 3.6V ½ AA Lithium Battery
Current Consumption: 30mA (transmission),
Pyroelectric Sensor: Dual Element
Maximum Coverage: 12 x 12m
Pulse Count: 1, 2, 3 or Adaptive
LED Indicator: Selectable
Adaptive Temperature Compensation
RFI Immunity: 30V/m
Operating Temperature: -10 to 60°C
Fire Protection: ABS Plastic Housing
Dimensions: 110 x 60 x 45mm
Specifications may be modified without prior notice.
Environmental Information for Customers in the European Union
European Directive 2002/96/EC requires that the equipment bearing this symbol
on the product and/or its packaging must not be disposed of with unsorted
municipal waste. The symbol indicates that this product should be disposed of
separately from regular household waste streams. It is your responsibility to
collection facilities appointed by the government or local authorities. Correct disposal and
recycling will help prevent potential negative consequences to the environment and human
health. For more detailed information about the disposal of your old equipment, please contact
your local authorities, waste disposal service, or the shop where you purchased the product.
dispose of this and other electric and electronic equipment via designated
MS845 6
SICHERHEITSHINWEISE
g
A
e
• Um Kurzschluss vorzubeugen, dieses Produkt bitte ausschließlich innerhalb des
Hauses und nur in trockenen Räumen nutzen. Setzen Sie die Komponenten nicht
Regen oder Feuchtigkeit aus. Nicht neben oder nahe eines Bades, Schwimmbades
usw. verwenden.
• Setzen Sie die Komponente Ihres Systems nicht extrem hohen Temperaturen
oder starken Lichtquellen aus.
• Bei einer zweckwidrigen Verwendung, selbst angebrachten Veränderungen oder
selbst ausgeführten Reparaturen verfallen alle Garantiebestimmungen. Marmitek
übernimmt bei einer falschen Verwendung des Produkts oder bei einer anderen
Verwendung des Produktes als für den vorgesehenen Zweck keinerlei
Produkthaftung. Marmitek übernimmt für Folgeschäden keine andere Haftung als
die gesetzliche Produkthaftung.
• Dieses Produkt ist kein Spielzeug. Außer Reichweite von Kindern halten.
• Halten Sie die Batterien außerhalb der Reichweite von Kindern. Liefern Sie die
Batterien als chemischen Kleinabfall ein. Verwenden Sie niemals alte und neue
oder unterschiedliche Typen von Batterien durcheinander. Wenn Sie das System
längere Zeit nicht benutzen, entfernen Sie die Batterien. Achten Sie beim Einlegen
der Batterien auf die Polarität (+ / -): Ein falsches Einlegen kann zu
Explosionsgefahr führen.
• Automatisches Schalten ist nicht nur bequem, sondern kann auch Gefahr
bedeuten. So können Personen überrascht werden, oder kann Kleidung, die über
eine elektrische Wärmequelle hängt in Brand geraten. Passen Sie immer auf und
treffen Sie Maßnahmen um dies zu verhindern.
Montierungsloch
EINFÜHRUNG
Dieses Produkt gehört den
Marmitek ProGuard800
Serien an und arbeitet mit
dem ProGuard800
Alarmsystem zusammen. Sie
möchten mehr erfahren über
das komplette System, die
Möglichkeiten und
Einstellungen der
ProGuard800 Serie? Schauen
Sie dann in die
Installierungsvorschriften oder
unter www.marmitek.com
.
Batterienhalter
Deckelschalter
Einstellun
DIP-
Schalter
Vertikale
sskala
LED
Easy
Lock
Modus
Steckbrück
ntenne
Pyrosensor
Alle diese Sensoren führen
eine Funktion aus, die das
Abbildung B.1: PIR Sensor ohne Abdeckung MS845
Problem der mehrfachen
Übertragungen bekämpfen. Diese mehrfachen Übertragungen reduzieren drastisch
das Leben der Batterien. Nach jeder Übertragung, gibt es eine vier Minuten
Verspätung während dieser keine weiteren Übertragungen geschickt werden. Der
• Wählen Sie aus der Tabelle B.1 eine angemessene Installationshöhe:
Richtlinien der Haustierimmunität (Pet Immunity)
Es wird angenommen, das der MS845 falsche Alarme beseitigt. Diese werden
durch folgende Faktoren bewirkt:
• Tiere bis zu 45kg (MS845)
• Mehrere kleine Nagetiere
• Willkürlich einfliegende Vögel
Das Gewicht des Tieres wird nur als Richtlinie benutzt. Andere Faktoren, wie
zum Beispiel die Länge und die Farbe des Felles wirken auch auf das
Immunitätsniveau.
Für eine maximale Haustierimmunität werden die folgenden Richtlinien empfohlen:
• Montieren Sie die Mitte der Einheit auf einer Höhe von 2m mit der platinen
vertikalen Einstellungshilfe auf -4.
• Stellen Sie den Impulszähler auf 2.
• Setzen Sie den Detektor nicht in der Treppenrichtung, die von einem Tier
geklettert werden kann.
• Vermeiden Sie einen Ort, wo sich ein Tier dem Detektor innerhalb von 1.8m
annähren kann, indem er auf Möbel, Kasten oder auf andere Objekte klettert.
INSTALLATIONSVERFAHREN
Um PIR Sensoren zu installieren:
1. Öffnen Sie das Gehäuse, indem Sie die vordere Seite abnehmen. Um dies
auszuführen, stecken Sie einen Schraubenzieher im Freilassungsschlitz ein
(befindet sich im unteren Teil des Detektors zwischen der vorderen und
hinteren Seite). Drehen Sie den Schraubenzieher um die 90º, damit die Seite
frei wird.
MS845 8
2. Entnehmen Sie die Platine, indem Sie gegen den Uhrzeigersinn drehen und
den Easy Lock entfernen – faßen Sie nicht die Fläche des Pyrosensoren an!
3. Wenden Sie Batteriestrom an, indem Sie den Isolatoren, der die Batterie von
den Kontakten des Batterieträgers teilt, entfernen.
Hinweis: Weil bei Lagerung von lithium Batterien Spannungsversluste
auftreten können kann es vorkommen dass es zunächst danach
aussieht, dass die Batterien kaputt sind. Lassen Sie die Einheit in
diesem Falle einige Minuten lang im Testmodus, bis sich das
Batteriespannungsniveau stabilisiert hat.
4. Setzen Sie die Modus Steckbrücke auf den Pins 2 & 3 (Radio Modus); die
LED-Anzeige blinkt.
Installieren Sie die Modus Steckbrücke, nur nachdem Batteriestrom
angewendet wurde.
5. Vom Programmierungsmenü, wählen Sie Module, Zonen [911] aus.
6. Suchen Sie eine Zone aus, in der Sie den Überträger registrieren wollen; das
System führt den Registrierungsmodus aus. Wenn Speichern? auf der
ProGuard800 LCD-Anzeige auftritt, drücken Sie auf 9.
7. Entfernen Sie die Modus Steckbrücke und stellen Sie die für eine Lagerung auf
einem Pin.
8. Wählen Sie eine angemessene Montierungshöhe aus der Tabelle B.1 und
testen Sie den Überträger für eine exakte Montierungsposition, bevor eine
endgültige Montierung der Einheit vorgenommen wird.
9. Brechen Sie die Montierungslöcher durch und befestigen Sie die Basis auf der
Wand.
10. Montieren Sie die Platine an der erforderten vertikalen Einstellung und setzen
Sie die Platinenschraube zurück.
11. Notieren Sie die Nummer der Zone auf dem zur Verfügung gestellten
Aufkleber. Kleben Sie für einen späteren Hinweis den Aufkleber auf der
inneren Seite der vorderen Abdeckung und stellen Sie die vordere Abdeckung
zurück.
Aufwärmungszeit
Der Detektor braucht eine
Aufwärmung, die 90 Sekunden
lang, nachdem der Strom
angewendet wurde, dauert.
Der Impulszähler bestimmt die Anzahl der
Strahlen, die überquert werden müssen bevor
der Detektor ein Alarm generiert. Um den
Impulszähler einzustellen, beziehen Sie sich auf
die Tabelle
Anpassungsfähiger Impulszähler (MS845)
Beim Benutzen der anpassungsfähigen
Impulszählerfunktion, sucht der Detektor
zwischen 1 oder 2 Impulsen aus. Er basiert sich
auf seine Analyse vom empfangenen Signals.
Vertikale Einstellung
Um die Platine zu installieren, drehen Sie den
Easy Lock gegen den Uhrzeigersinn und gleiten
Sie die Platine nach unten oder nach oben zu der
erforderten Einstellung, indem Sie die vertikale
Figure B.2: Abbildung B.2:
Linsenbedeckungsdiagramme
MS845
Einstellungsskala benutzen. Der
Erfassungsbereich des Detektors beträgt 14m x 14m (/) oder 12m x 12m (/MS845)
wenn die Platine auf 0 positioniert wird. Gleiten Sie die Platine nach oben auf –8 um die
Bedeckungszone zu verringern, indem die Strahlen näher zur Montierungswand
gebracht werden.
Gehtest Modus
Ein Gehtest ist ausgeführt, um das Linsenbedeckungsmuster vom Detektoren zu
bestimmen. Der Gehtest Modus sagt die Verzögerungszeiten zwischen den Detektoren
ab, und ermöglicht Ihnen einen leistungsfähigen Gehtest auszuführen.
Um einen Gehtest auszuführen.
1. Stellen Sie die Modus Steckbrücke auf Pin 1 & 2.
2. Durchqueren Sie den Detektorenbereich, gemäß dem ausgewählten
Detektionsmuster.
3. Vergewissern Sie sich daß, das LED entsprechend aktiviert und deaktiviert
wird. Warten Sie fünf Sekunden nach jeder Detektion, bevor Sie mit dem Test
weitermachen.
4. Nachdem Sie den Gehtest vervollständigt haben, entfernen Sie die
Steckbrücke und stellen Sie sie für eine Lagerung auf einem Pin – siehe Modus Steckbrückenschutz.
MS845 10
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.