MAMAC Systems CU-850, CU-860, CU-870, CU-880, CU-855 Data Sheet

...
Current Sensors
Model CU-850/860/870/880
CU-855/865/875/885
• Available in two transformer core configurations: solid or split-core for ease
....of installation
Self powered, no external power supply
required for VDC output units
....0-5 VDC or 4-20mA
Three field selectable ranges in each unit
UL listed and CE certified
True RMS measurement
Up to 200 amp range
RoHS
CU series Current Sensors provide a reliable and low cost solution to monitor current of supply/exhaust fans, pumps, compressors, unit ventilators, lighting or any equipment. Current Sensors are available with a solid core or split core configuration for ease of installation. Two models are available with field selectable ranges to cover 10 amps to 200 amps full scale. The current sensors incorporate sophisticated electronics to provide true RMS measurement from 20 to 100 Hz frequency. The VDC output sensor is self powered and does not require external power. The 4-20 mA sensor is 2-wire loop powered and can handle 15-40 VDC. 5 year warranty, UL listed, CE certified and the lowest cost in the industry are some of the features which make the sensors an ideal solu­tion for load status monitoring and alarming functions.
DN850.1
® Registered trademark MAMAC SYSTEMS, Inc.
© Copyright 2013
SPECIFICATIONS:
CU-850/860/870/880 CU-855/865/875/885
Supply Voltage: Self-Powered (0-5 VDC output)
15-40 VDC (4-20mA output)
Accuracy: +/- 1% FS
Housing: UL 94-V-0 Flame retardant ABS Plastic
Isolation Voltage: 1000 VAC
Termination: Terminal Block 14 Ga max
Frequency Range: 20-100 Hz
Response Time: 250 ms (0-90%)
Operating Temp: 32°
Environmental: 0-95% RH, Non-Condensing
158°F (070°C)
Weight: .25 lbs ( .11 kg)
Agency Approvals: UL listed, CE certified
Max. Input Current: 10/20/50 amp range - 80/120/200 amps continuous
50/100/200 amp range - 175/300/400 amps continuous
CONFORMANCE & TESTING:
RoHS Compliant EMC Testing:
BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11
ORDERING INFORMATION:
Model Description
CU-850
CU-855
CU-860
CU-865
CU-870
CU-875
CU-880
CU-885
CAUTION: Do not use in explosive/hazardous environment.
Solid-core, 10 / 20 / 50 amps, 0 - 5 VDC output
Split-core, 10 / 20 / 50 amps, 0 - 5 VDC output
Solid-core, 100 / 150 / 200 amps, 0 - 5 VDC output
Split-core, 100 / 150 / 200 amps, 0 - 5 VDC output
Solid-core, 10 / 20 / 50 amps, 4 - 20 mA output
Split-core, 10 / 20 / 50 amps, 4 - 20 mA output
Solid-core, 100 / 150 / 200 amps, 4 - 20 mA output
Split-core, 100 / 150 / 200 amps, 4 - 20 mA output
DN850.1
2
® Registered trademark MAMAC SYSTEMS, Inc.
© Copyright 2013
Loading...
+ 2 hidden pages