Majestic SB60 Specifications

Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
Rough
SB60
Actual Framing Actual Framing Actual
44-1/2" 45-1/2" 28-5/8" 45-1/2" 59-1/4" 59-3/4" 27-1/2" 28"
Opening Framing*
Actual Framing
* Framing must be filled in to top of front
standoff after unit is installed.
BILTMORE 60
36" Wood Fireplace
36" x 28-1/2"
28-5/8"
[727]
14-3/8"
[365] 9-1/2"
27-1/2"
[241]
[699]
44-1/2"
Top View
SB60
Knockout
8-5/8"
[219]
9-5/8"
[244]
Outside
Air
Gas
9-1/4"
[235]
9-1/2"
[241]
59-1/4"
49-5/8"
7-5/8"
[194]
36"
[914]
Front View
49-1/8"
28-1/2"
[724]
55-1/2"
effective
height
Gas
Knockout
8-5/8"
[219]
18-1/2"
[470]
Left Side View Right Side View
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
duct. Extra space needed for outside
as long as minimum clearances are met.
Header will sit on top of front stand o is installed.
17"
[610]
Continuous,
material
HX4 Hearth Ext or equivalent insulation. See install manual
Metal Hearth
[305]
Combustible Object
minimum base
Noncombustible Decorative Facing such as: stell, iron, brick, tile, concrete, slate, glass, plasters
of the framing material.
Specifications
SB60
APPLIANCE LOCATION
[492]
48"
min.
53-1/2"
[1359]
24"
[610]
divider
60-1/8" [1527]
45-1/2"
[1156]
45-1/2"
[1156]
As a room
28"
[711]
85"
[2159]
Across a
corner
45-1/2" [1156] 53-1/2" [1359]
In an exterior
chase or projecting
into a garage
Along a wall
53-1/2" [1359] 45-1/2" [1156]
42-1/2"
[1080]
19-3/8"
[1219]
MANTEL PROJECTIONS
Combustible Wall
2 x 4 stud wall
Standoffs
Seal joint with non-combustible sealant
Combustible Decorative Facing
12" [305]
12" [305] minimum
6" [152]
mimimum 1-1/2" [38] maximum
Measured from top of fireplace opening
MANTEL LEG/WALL PROJECTIONS
Grid represents
1" scale
FLUSH
FRONT
22-3/8"
[568]
50° angle
36" [914]
44-1/2" [1130]
24"
HEARTH EXTENSIONS
24"
[610]
24"
[610]
7 ft [2134]
of fireplace
to ceiling
BRICK
FRONT
39° angle
24"
[610]
28"
[711]
1/2" [13] all
configurations
28"
[711]
4"
[102]
19-3/4"
[502]
FRAMING DIMENSIONS
1/2" [13]
[432]
2" [51]
ffs after fireplace
**28" [711]
** If interior of chase will be drywalled, add the thickness to this measurement
*8"
[203]
45-1/2"
[1156]
* 4" air connection. If outside air duct has no bend, this dimension may be reduced
Fireplace must be set out 1/2 [13] in front of the face
Header MUST NOT be notched!
CLEARANCES TO COMBUSTIBLES
Storm Collar
Roof Flashing
(insulation)
2" [51] min.
Ceiling Firestop
48"
[1219]
(attic)
0" to floor
(roof)
Shaded areas represent 2" [51] minimum air space clerance required around pipe.
Attic Insulation Shield
(ceiling)
Offset/Return (secured with hanger straps)
(ceiling)
Must have 2" [51] minimum clearance to header
Adapter attached here (not shown)
0" to level of standoffs
Back & sides of unit 1" [25] (except at nail flanges where it is 1/2" [13]
HEARTH EXTENSION CONSTRUCTION
non-combustable
Tile, stone or other non-combustible material
Floor constructed of wood or other combustible
sealant
2" [51] required
Protective
Fireplace
Strip
60" [1524]
12"
20"
[508]
Lakeville, MN Phone: (800) 927-6841 Web: www.majesticproducts.com
PRODUCT LISTING CODES
US UL 127
CAN ULC-S610
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Additional information can be found online at www.majesticproducts.com
MAJ/SB60_0817