Majestic SB100HB Specifications

Knockout
[483]
Knockout
[483]
[267]
41-5/8" [1057]
Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
Rough
SB100
Actual Framing Actual Framing Actual
60-5/8" 61-5/8" 41-5/8" 61-5/8" 70-1/2" 71" 29-1/2" 30-1/2"
Opening Framing*
20-3/4"
Actual Framing
* Framing must be filled in to top of front
standoff after unit is installed.
BILTMORE 100
50" Wood Fireplace
50" x 33"
[527]
11-5/8"
29-1/2"
[295]
[749]
60-5/8" [1540]
Top View
SB100
Outside
Gas
9-7/8"
[251]
Air
68-1/8"
[1730]
effective height
[838]
8-3/4 [222]
14-3/4"
[375]
10-1/2"
50" [1270]
Front View
60-1/4"
54-3/8"
[1381]
[1530]
14-3/4"
10-1/2"
[267]
70-1/2"
[1791]
[375]
Outside
Air
Gas
9-7/8"
[251]
Left Side View Right Side View
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
configurations
Use only non-combustible
to this measurement
Header will sit on top of front standoffs after fireplace is installed.
17"
[610]
[610]
19-3/4"
22-3/8"
Continuous, non-combustible
Metal Hearth
Flush Hearth
0" to level of standoffs
1-1/2" [38] from side of unit
7 ft [2134] minimum
Non-combustible Decorative Facing such as: steel, iron brick, tile, concrete, slate, plasters
of the framing material.
Specifications
SB100
APPLIANCE LOCATION
As a
room
divider
48"
[1219]
74-1/4"
[1886]
104-7/8"
77-5/8"
[1972]
24"
[610]
61-5/8"
[1565]
[2664]
Across a
corner
30-1/2"
24-3/8"
52-1/2"
[1334]
[619]
MANTEL PROJECTIONS
Combustible Wall
2 x 4 stud wall
77-5/8" [1972]
In an exterior chase
or projecting into
a garage
[775]
Along a wall
77-5/8" [1972]
Combustible Decorative Facing
12" [305]
Mantel
24"
[610]
base of fireplace
20" [508] minimum
30-1/2"
[775]
30-1/2"
[775]
to ceiling
1/2" [13] all
FRAMING DIMENSIONS
1/2" [13]
[432]
2" [51]
material below the top of
*8"
[203]
the front standoffs.
**30-1/2"
[722]
** If interior of chase will be drywalled, add the thickness
61-5/8"
[1565]
* Extra space needed (both sides) for outside air connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met.
CLEARANCES TO COMBUSTIBLES
Storm Collar
Roof Flashing
(roof)
Fireplace must be set out 1/2 [13] in front of the face
MANTEL LEG/WALL PROJECTIONS
HEARTH EXTENSIONS
Front Standoffs
Seal joint with non-combustible sealant
Grid represents 1" scale
FLUSH
FRONT
[568]
50° angle
24"
1-1/ 2" [38] maximum
6" [152] minimum
Measured from top of fireplace opening Grid represents 1" squares
50" [1270]
60-5/8" [1540]
12"
[305]
50"
[1270]
74"
[1880]
12" [305] minimum
12"
[305]
Raised Hearth
20" [508] minimum
BRICK
FRONT
39° angle
24"
4"
[102]
[502]
30" [762] minimum
Lakeville, MN Phone: (800) 927-6841 Web: www.majesticproducts.com
2" [51]
2" [51] minimum
(attic)
minimum
Attic Insulation Shield
Ceiling Firestop
(ceiling)
2" [51] minimum
Ceiling Firestop
2" [51] minimum
Offset/Return with hanger straps
(ceiling)
2" [51] minimum
0" from
floor
2" [51] minimum
2" [51] minimum to header
1-1/2" [38] from back of unit
(except at nailing flanges where it is 1/2" [13]
HEARTH EXTENSION CONSTRUCTION
sealant
Tile, stone or other 1/2" [13] Micore or equivalent insulation See Install Manual
Floor constructed of wood or other combustible material
PRODUCT LISTING CODES
US UL 127
Additional information can be found online at www.majesticproducts.com
non-combustible material
2" [51] required
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Protective
Fireplace
Strip
MAJ/SB100_0817