Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
Rough
SB100
Actual Framing Actual Framing Actual
60-5/8" 61-5/8" 41-5/8" 61-5/8" 70-1/2" 71" 29-1/2" 30-1/2"
Opening
Framing*
20-3/4"
Actual Framing
* Framing must be filled in to top of front
standoff after unit is installed.
BILTMORE 100
50" Wood Fireplace
50" x 33"
[527]
11-5/8"
29-1/2"
[295]
[749]
60-5/8" [1540]
Top View
SB100
Outside
Gas
9-7/8"
[251]
Air
68-1/8"
[1730]
effective height
33"
[838]
8-3/4
[222]
14-3/4"
[375]
19"
10-1/2"
50" [1270]
Front View
60-1/4"
54-3/8"
[1381]
[1530]
14-3/4"
10-1/2"
[267]
70-1/2"
[1791]
[375]
19"
Outside
Air
Gas
9-7/8"
[251]
Left Side View Right Side View
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
to this measurement
Header will sit
on top of front
standoffs after
fireplace is
installed.
Continuous, non-combustible
1-1/2" [38] from side of unit
Non-combustible
Decorative Facing
such as: steel, iron
brick, tile, concrete,
slate, plasters
Specifications
SB100
APPLIANCE LOCATION
As a
room
divider
48"
[1219]
74-1/4"
[1886]
104-7/8"
77-5/8"
[1972]
24"
[610]
61-5/8"
[1565]
[2664]
Across a
corner
30-1/2"
24-3/8"
52-1/2"
[1334]
[619]
MANTEL PROJECTIONS
Combustible Wall
2 x 4 stud wall
77-5/8" [1972]
In an exterior chase
or projecting into
a garage
[775]
Along a wall
77-5/8" [1972]
Combustible
Decorative Facing
12" [305]
Mantel
24"
[610]
base of fireplace
20" [508]
minimum
30-1/2"
[775]
30-1/2"
[775]
to ceiling
1/2" [13] all
FRAMING DIMENSIONS
1/2"
[13]
[432]
2" [51]
material below the top of
*8"
[203]
the front standoffs.
**30-1/2"
[722]
** If interior of chase will be
drywalled, add the thickness
61-5/8"
[1565]
* Extra space needed (both sides)
for outside air connection. If outside
air duct has no bend, this dimension
may be reduced as long as minimum
clearances are met.
CLEARANCES TO COMBUSTIBLES
Storm Collar
Roof Flashing
(roof)
Fireplace must be set out
1/2 [13] in front of the face
MANTEL LEG/WALL PROJECTIONS
HEARTH EXTENSIONS
Front Standoffs
Seal joint with
non-combustible
sealant
Grid represents
1" scale
FLUSH
FRONT
[568]
50° angle
24"
1-1/ 2" [38]
maximum
6" [152]
minimum
Measured from top of fireplace opening
Grid represents 1" squares
50" [1270]
60-5/8" [1540]
12"
[305]
50"
[1270]
74"
[1880]
12" [305]
minimum
12"
[305]
Raised Hearth
20" [508]
minimum
BRICK
FRONT
39° angle
24"
4"
[102]
[502]
30" [762]
minimum
Lakeville, MN Phone: (800) 927-6841
Web: www.majesticproducts.com
2" [51]
2" [51]
minimum
(attic)
minimum
Attic
Insulation
Shield
Ceiling Firestop
(ceiling)
2" [51]
minimum
Ceiling Firestop
2" [51]
minimum
Offset/Return with
hanger straps
(ceiling)
2" [51]
minimum
0" from
floor
2" [51]
minimum
2" [51] minimum
to header
1-1/2" [38] from
back of unit
(except at nailing flanges
where it is 1/2" [13]
HEARTH EXTENSION CONSTRUCTION
sealant
Tile, stone or other
1/2" [13] Micore or
equivalent insulation
See Install Manual
Floor constructed of wood or
other combustible material
PRODUCT LISTING CODES
US UL 127
Additional information can be found online at www.majesticproducts.com
non-combustible material
2" [51]
required
Product information provided is not
complete and is subject to change without
notice. Product installation must adhere
strictly to instructions accompanying
product to avoid risk of fire and potential
injury.
Protective
Fireplace
Strip
MAJ/SB100_0817