Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING
SA42
Actual Framing Actual Framing Actual Framing Actual Framing
48" 49" 30-7/8" 49" 41-1/4" 41-1/2" 22-3/4" 23"
30-7/8" [784]
15-1/2"
[394]
8-3/4"
[222]
22-3/4"
[578]
48" [1219]
SOVEREIGN
42" Wood Fireplace
42" x 23-3/8"
Top View
SA42
9-1/4"
[235]
Gas Knockout
Outside
Air
23-3/8"
[594]
8-1/16"
[205]
Ø10-1/2"
[267]
42" [1067]
Front View
41-1/4"
[1048]
(effective height)
Gas Knockout
Junction
Box
3-7/8"
[92]
41-3/8"
[1051]
9-1/4"
[235]
9-5/8"
[244]
4-1/4"
[108]
13-1/2"
[343]
8-5/8"
[219]
Left Side View Right Side View
Additional information can be found online at www.majesticproducts.com or www.fireplaces.com
7-1/2"
[191]
13-1/2"
[343]
4-1/4"
[108]
Specifications
**
raised floor under fireplace
front and sides of fireplace opening by 2" [51]
SA42
APPLIANCE LOCATION
54-7/8" [1394]
18"
[457]
49"
[1245]
Across a
77-1/2"
38-7/8"
[987]
As a
room
divider
48"
[1219]
minimum
See
NOTE
[1969]
57"
[1448]
49"
[1245]
corner
23"
[584]
MANTEL PROJECTIONS
Combustible Wall
2 x 4 stud wall
Standoffs
Seal joint with
non-combustible
sealant
1-1/2" [38]
maximum
Non-combustible
Decorative Facing
such as:
steel, iron, brick,
tile, concrete, slate,
glass, plasters.
Combustible
Decorative Facing
Measured from top of fireplace opening
49" [1245]
57" [1448]
In an exterior chase
or projecting into a
garage
Along a wall
57" [1448]
49" [1245]
12" [305]
Mantel
12" [305]
minimum
6" [152]
minimum
23"
[584]
See
NOTE
[584]
6 ft [1829] minimum
base of fireplace
to ceiling
NOTE: 12" [305]
minimum from
fireplace opening
to perpendicular
wall
1/2" [13] all
23"
FRAMING DIMENSIONS
15"
2" [51] min.
air clearance
to enclosure
[381]
Adjust header height for
41-1/2"
[1055]**
49" [1245]
23" [584]*
* If interior of chase will
be drywalled, add thickness
CLEARANCES TO COMBUSTIBLES
Storm Collar
Roof Flashing
2" [51] min.
(attic)
2" [51] min.
Ceiling Firestop
2" [51] min.
(ceiling)
2" [51] min.
2" [51] min.
(roof)
2" [51] min.
Insulation
Ceiling Firestop
(ceiling)
2" [51] min.
Offset/Return with
hanger straps
0" to level
of standoffs
Attic
Shield
8"
[203]
be notched
MANTEL LEG/WALL PROJECTIONS
HEARTH EXTENSIONS
10-3/4"
[273]
FLUSH
FRONT
42" [1067]
50° angle
48" [1219]
12"
12"
66"
[1676]
[305]
12"
[305]
39° angle
20"
[508]
4"
BRICK
[102]
FRONT
12"
9-3/4"
[248]
48"
[1219]
0" to floor
3/4" [19] to back
of appliance
3/4" [19] to side of appliance
(except at nailing flanges where it is 1/2" [13])
HEARTH EXTENSION CONSTRUCTION
Finished combustible wall
Combustible material
Non-combustible
decorative facing
(up to full brick depth)
Continuous,
non-combustible sealant
Tile, stone or other
non-combustible material
HX3 or HX4 Hearth Ext
or equivalent insulation
Metal strips are placed 2" [51] under the front
of the fireplace and must extend beyond the
PRODUCT LISTING CODES
US UL 127
CAN ULC-S610
Additional information can be found online at www.majesticproducts.com
Flat 2 x 4 stud wall
2 x 4 header, flush with
front of stand-offs
Hearth
Refractory
Floor constructed of wood or
other combustible material
Product information provided is not
complete and is subject to change without
notice. Product installation must adhere
strictly to instructions accompanying
product to avoid risk of fire and potential
injury.
Lakeville, MN Phone: (800) 927-6841
Web: www.majesticproducts.com
MAJ/SA42_0817