Magic Chef 8241RB, 8241RT, 8241RV, 8241RS, 8241RW Dimension Guide

...
0 (0)
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Magic Chef
• Product Model Number (s): •
Gas Cooktops:
8241RB, 8241RT, 8241RV, 8241RS, 8241RW, 8241RA
and 8241RQ
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from countertop to bottom of unit:
Cut-Out width:
Cut-Out depth:
30" 21" 3 3/8" 28 3/8" 19 3/4"
Minimum spacing to nearest vertical
combustible wall to the RIGHT:
3"
Minimum spacing to nearest vertical
combustible wall to the LEFT:
3"
Minimum spacing to nearest vertical
combustible wall to the REAR:
Minimum spacing to front edge of counter:
1" 2"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30" min 30"
Maximum depth of cabinets directly
above and adjacent:
13"
Minimum distance between countertop
and adjacent cabinet above:
18"
• Additional Information •
• Designed to fit in a standard 30" wide cabinet and 25"
deep countertop.
• Electrical requirements: 120 volts 60 Hz protected by
a 15 amp fuse or compatible circuit breaker. Minimum wire size is 14 gauge. Copper wire only. Unit is supplied with a power cord having a 3-prong grounding plug. A grounded and polarized 3-prong receptacle should be made available. Individual branch circuit serving the cooktop is recommended.
• Gas requirements: Supply line should be 3/4" and
enter the cooktop in right rear corner of unit. Unit is shipped from factory for use on natural gas. Unit is equipped with built-in conversion for use on LP gas.
- Supplied with 1/2" NPT female inlet on regulator.
Regulator supplied with unit and a shutoff valve must be installed in an accessible location.
- Gas pressure requirements: Natural gas- 4" WC min,
14" WC max. LP gas- 10" WC min, 14" WC max.
3 3/8"
Side View (not to scale)
1"
19 3/4"
28 3/8"
2"
3" 3"
30" min
18"
2 1/16" to centerline of pipe from back edge of cutout
30"
21"
Overall Dimensions
Cut-Out Dimensions
Countertop View
(not to scale)
Cabinet Requirements
Wall View
(not to scale)
30"
Requires 18" high by 3" wide clearance to any combustible surface above the cooktop on both sides. (noted by solid area)
Gas inlet location
1 5/16" to centerline of pipe from left edge
Top view of cutout
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
252
Cooktop supplied with 1/2" NPT female inlet on regulator
(not to scale)
of cutout
BN • A252 • 31510 • 030805 • 10859 • 73846
Loading...