www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
|
|
This Data Sheet Includes Information On |
|
|
|
|
Magic Chef |
|
|
• |
Product Model Number (s): |
• |
||
|
|
Slide-In Electric Ranges: |
|
|
|
|
CES3760AAB, CES3760AAW and CES3760AAQ |
|
|
• |
Dimensions (Actual Size) |
• |
||
|
|
Width of top frame: |
30 3/4" |
|
|
|
Width of case: |
30" |
|
|
|
Depth: |
26 5/16" |
|
|
|
Height: |
36 7/16" |
|
|
|
Door swing: n/a |
|
|
|
|
Height at full leg adjustment: 38" |
|
|
|
|
Height at 0" leg adjustment: 36" |
|
|
|
• |
Additional Information |
• |
•Units depth including door handle is 28 3/8".
•Electrical requirements: 120/240 VAC or 120/208 VAC, 60Hz. 50 amp grounded individual circuit is required.
•Proper operation requires use of range hood.
•Cabinetry over cooktop : 30' minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper.
•To eliminate the hazard of reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.
•Range complies with U.L. requirements for 0" clearance from the range to adjacent vertical side walls and 0" from rear wall.
•Island or peninsula installations with 24" deep base cabinets must use flush back (no rear toe space) cabinets to avoid range interference,. If rear toe space is desired, use 27" or deeper cabinets.
•Some European style cabinets are equipped with vinyl drawer and door fronts. The vinyl may not be designed to withstand the heat produced by the normal operation of the self cleaning range. Discoloration or delamination may occur. To avoid possible damage, Maytag recommends increasing the 30" cabinet opening to 30 1/4" minimum and using a heat shield kit #CABKIT V. The countertop cutout must remain 30".
See page 2 for additional information
Subject to change without notice. This system is designed to |
|
be updated daily if necessary. Dimension Express is not |
|
responsible for use of superseded, voided, or outdated data |
|
sheets. Because of the difficulty or impracticability of deter- |
|
mining actual damages, liability of Dimension Express shall |
|
not exceed $50.00. |
|
Copyright © Dimension Express, 2002. |
392 |
30 3/4"
26 5/16"
(not to scale)
36 7/16" |
|
30" |
|
|
|
n/a
|
Locate electrical |
|
supply junction |
|
box or 60" of |
|
electrical cable |
|
within shaded |
Wall View |
area. Outlet must |
(not to scale) |
be flush. |
5 1/2" |
19" |
10" |
|
|
|
Upper cabinets |
|
Wall View |
|
can only be 13" |
|
|
deep maximum. |
||
(not to scale) |
30" |
||
Over range |
|||
|
|
||
|
|
cabinet is NOT |
|
|
|
recommended. |
|
|
30" Min. |
|
|
18" |
|
Side clearance |
|
|
from cooktop to |
||
|
|
||
|
|
18" above the |
|
|
|
cooktop is 3" on |
|
|
|
each side (see |
|
36" |
Range |
solid arera) |
|
Countertop |
|
||
|
|
||
height |
|
30" Minimum |
|
|
|
||
|
|
cutout width |
• NEVER reuse Data Sheets. Data Sheets are subject to change without |
• Call Dimension Express if you have any questions at (775) 833-3633 • |
notice. Dimension Express is a FREE service bureau and is updated daily, |
• Always refer to a current Code at a Glance or manufacturer directory • |
it makes far more sense to spend the time necessary to request new Data |
• Data Sheet codes change on the first of odd numbered months at 12:01am • |
Sheets for each project, as opposed to the problems, time, costs, and risks |
BN • A392B149 • 31510 • 032603 • 95659 • 25064 |
associated with reusing old Data Sheets. |