Magellan MHI1-548 User Manual

HYBRID SERIES USER MANUAL
350-00xxx-00
HYBRID INVERTER
M 64 bushland Ridge Bibra Lake,Perth Western Australia,6148 support@magellan-power.com.au Worldwide +61 89434 6621 Fax +61 89 434 6623
1 Introduction
2 Important Safety Warning
3 Installation
4 Electrical Connection
5 LED Lights Illustration
6 HESS APP Illustration
7 Work Modes Error Messages8 9Technical Parameters
10 Certificates
3.1 Packing List
3.2 Product Overview
3.3 Selecting The Mounting Location
3.4 Mounting
.. ......................... 03.............
.......................... ....... 03
............. 04
........ ........... 05........................
............................................................... 14
.......................................................................................... 01
..... ................................. 15....................................................
......... ..... .................................... 16.... ............................
.... ................................ 17............................
......... ................................................. 19.....................................
4.1 AC Output Connection
4.2 PV Connection
4.3 Battery Connection
4.4 RS-485 Connection
4.5 HESS Meter Connection
4.6 Wi-Fi Connection
4.7 Wi-Fi Reset & Reload
4.8 USB Connection
4.10 Processing method of batteries connect
multiple inverters
4.9 System Connection Diagram
........................... 05
........................ . ............ 07
...... ................. 08........
...... .................. 09........
...... .............. 10......
.................................. 11
...... ........... 11............
...... ......................... 12.....
.... .. ....... 12.... ...
... .. ...................... 14................................... ..
2.1 Symbols
2.2 Safety
. ......................... 01...................
........................................ ....... 02
................................. 13
1 Introduction
Before using the inverter, please read all instructions and cautionary markings on the unit and this manual. Store the manual where
it can be accessed easily.
The hybrid series inverter of Magellan Powertronics Pty Ltd. (hereinafter referred to as Magellan) strictly conforms to related safety
rules in design and test.
Safety regulations relevant to the location shall be followed during installation, operation and maintenance.
Improper operation may have a risk of electric shock or damage to equipment and property.
01
2 Important Safety Warning
02
Caution! Failure to observe a warning indicated in
this manual may result in injury.
Danger of high voltage and electric shock!
Danger of hot surface!
Components of the product can be recycled.
This side up; the package must always be
transported, handled and stored in such a way
that the arrows always point upwards.
No more than six (6) identical packages may
be stacked on each other.
Magellan hybrid series inverters are bidirectional which apply to PV system with battery to store energy. Energy produced by the PV system is used to optimize self-consumption; excess energy is used to charge the batteries, and then fed into the public grid when the PV energy is adequate, When PV energy output is insufficient to support connected loads, the system automatically get energy from the batteries if battery capacity is abundant. If the battery capacity is insufficient to meet own consumption requirements, electricity will be drawn from the public grid. Magellan hybrid series inverter is design for both indoor and outdoor use.
Figure 1-1 Basic hybrid PV system overview
2.1 Symbols
Product should not be disposed as
household waste.
CE Mark
Keep dry; the package/product must be
protected from excessive humidity and must be
stored under cover.
Signals danger due to electrical shock and indicates the time (5 minutes) to allow after the
inverter has been turned off and disconnected to ensure safety in any installation operation.
The package/product should be handled
carefully and never be tipped over or slung.
2.2 Safety
Installation, maintenance and connection of inverters must be performed by qualified personnel, in compliance with local electrical standards, wiring rules and the requirements of local power authorities and/or companies (for example : AS 4777 and AS/NZS
3000 in Australia).
To avoid electric shock, DC input and AC output of the inverter must be terminated at least 5 minutes before performing any
installation or maintenance.
The temperature of some parts of the inverter may exceed 60during operation. To avoid being burnt, do not touch the inverter
during operation. Let it cool before touching it.
Ensure children are kept away from inverters.
Do not open the front cover of the inverter. Apart from performing work at the wiring terminal (as instructed in this manual),
touching or changing components without authorization may cause injury to people, damage to inverters and annulment of the
warranty.
Static electricity may damage electronic components. Appropriate method must be adopted to prevent such damage to the
inverter; otherwise the inverter may be damaged and the warranty annulled.
Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter; otherwise the
inverter may be damaged and the warranty annulled.
When exposed to sunlight, the PV array generates dangerous high DC voltage. Please operate according to our instructions, or it
will result in danger to life.
PV modules should have an IEC61730 class A rating.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.
Completely isolate the inverter before maintaining. Completely isolate the inverter should Switch off the DC switch, disconnect
the PV terminal, disconnect the battery terminal, and disconnect the AC terminal.
Prohibit to insert or pull the AC and DC terminals when the inverter is running.
In Australia, the inverter internal switching does not maintain the neutral integrity, neutral integrity must be addressed by external
connection arrangements like the example proposed in the diagram 4.9.
● In Australia, the output of backup side in switchbox should be labeled 'main switch UPS supply', the output of normal load side in
switchbox should be labeled 'main switch inverter supply'.
Refer to the operating instructions.
03 04
Figure 3.3-1
3.2 Product Overview
1 2
3
4
5
9
6 7
Mounting location should be selected based on the following aspects:
● The installation method and mounting location must be suitable for the inverter's weight and dimensions.
● Mount on a solid surface.
● Select a well ventilated place sheltered from direct sun radiation.
● Install vertically or tilted backward by max 15°. The device cannot be installed with a sideways tilt. The connection area must point
downwards. Refer to Figure 3.3-1.
than the following value:
In consideration of heat dissipation and convenient dismantlement, the minimum clearances around the inverter should be no less
Upward ----------300mm
Downward--------500mm
Front-------------300mm
Both sides---------500mm
Figure 3.3-2
300mm
500mm
500mm 500mm 300mm
3.3 Selecting The Mounting Location
● For the convenience of checking the LED lights and possible maintenance activities, please install the inverter at eye level.
● Inverters should NOT be installed near inflammable and explosive items. Any strong electro-magnetic equipment should be kept
away from installation site.
● Product label and warning symbol shall be clear to read after installation.
● Please avoiding direct sunlight, rain exposure, snow lay up when installing.
In order to achieve optimal performance, the ambient temperature should be lower than 45 °C.
Direct Sunlight
Rain Exposure
Snow Lay up
No direct sunlight
No Rain Exposure
No Snow Lay up
3.1 Packing List
3 Installation
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the
following items inside of package:
1. Battery input terminals
2. PV input terminals
3. DC Switch (Optional)
4. Wi-Fi antenna port
5. USB port
6. RS-485 port
7. Back-Up port
8. On-Grid port
9. LED lights
8
Max
15°
Wall-mounted
Bracket×1
Inverter×1
Quick Installation
Guide×1
Instruction
of
Fast
Installation
Wi-Fi Connection
Guide×1
Wi-Fi Connection
Configuration
Battery cover × 1
AC cover × 1
AC terminal × 6
Battery terminal × 2
Negative DC
Plug×2
or
User Manual×1
User
manual
Expansion Bolts×6
Hexagon head
screw × 2
Pan head screw × 8
Positive DC Plug×2
or
HESS Meter × 1
Single Energy Meter
Antenna×1
Loading...
+ 8 hidden pages