DX-RVC Predefined Functions
DX-RVC Remote Volume Control (2-button/12-LED)
Switch Positions
ID 1 through 8 Function
0 00000000 Input Level 1A (1)
1 10000000 Input Level 1A (2)
2 01000000 Input Level 1B (1)
3 11000000 Input Level 1B (2)
4 00100000 Input Level 2A (1)
5 10100000 Input Level 2A (2)
6 01100000 Input Level 2B (1)
7 11100000 Input Level 2B (2)
8 00010000 Input Level 3A (1)
9 10010000 Input Level 3A (2)
10 01010000 Input Level 3B (1)
11 11010000 Input Level 3B (2)
12 00110000 Input Level 4A (1)
13 10110000 Input Level 4A (2)
14 01110000 Input Level 4B (1)
15 11110000 Input Level 4B (2)
16 00001000 Input Level 5A (1)
17 10001000 Input Level 5A (2)
18 01001000 Input Level 5B (1)
19 11001000 Input Level 5B (2)
20 00101000 Input Level 6A (1)
21 10101000 Input Level 6A (2)
22 01101000 Input Level 6B (1)
23 11101000 Input Level 6B (2)
24 00011000 Input Level 7A (1)
25 10011000 Input Level 7A (2)
26 01011000 Input Level 7B (1)
27 11011000 Input Level 7B (2)
28 00111000 Input Level 8A (1)
29 10111000 Input Level 8A (2)
30 01111000 Input Level 8B (1)
31 11111000 Input Level 8B (2)
Each of the predefined functions has two IDs (1) and (2) to allow two remote controls
to perform the same function.
Switch Positions
ID 1 through 8 Function
32 00000100 Output Level A (1)
33 10000100 Output Level A (2)
34 01000100 Output Level B (1)
35 11000100 Output Level B (2)
36 00100100 Output Level A&B (1)
37 10100100 Output Level A&B (2)
38 01100100 Group Level 1 (1)
39 11100100 Group Level 1 (2)
40 00010100 Group Level 2 (1)
41 10010100 Group Level 2 (2)
42 01010100 Group Level 3 (1)
43 11010100 Group Level 3 (2)
44 00110100 Group Level 4 (1)
45 10110100 Group Level 4 (2)
46 01110100 Group Level 5 (1)
47 11110100 Group Level 5 (2)
48 00001100 Group Level 6 (1)
49 10001100 Group Level 6 (2)
50 01001100 Group Level 7 (1)
51 11001100 Group Level 7 (2)
52 00101100 Group Level 8 (1)
53 10101100 Group Level 8 (2)
54-255 Reserved for future
updates
industrial@mackie.com
16220 Wood-Red Road NE Woodinville, WA 98072
TEL +888.337.7404, FAX +425.487.4337
UK +44.1268.570.808, FAX +44.1268.570.809 +industrial@rcf-uk.com
ITALY +39.0522.354.111, FAX +39.0522.332.294 +industrial@rcf.it
FRANCE +33.3.8546.9160, FAX +33.3.8546.9161 +industrial@rcf.fr
GERMANY +49.2572.96042.0, FAX +49.2572.96042.10 +industrial@mackie.de
Part No. 910-298-20 Rev. B 9/00
© 2000 Mackie Industrial. All Rights Reserved. Printed in the USA.
The DX-RVC is a real-time remote volume
control for use with the DX8 Digital Audio
Mixer/Signal Processor. The DX-RVC can be
programmed to operate the volume for any of
the eight inputs, either output, grouped
outputs, or Group Levels 1-8. The predefined
functions are programmed via the eight DIPswitches on the back of the circuit board. Up
to nine remote controls (including the DX-RVC
and the DX-SW4) can be connected to the DX8
REMOTE BUS
connector.
Safety First!
Before connecting and using the
equipment, please read this Quick-Start Guide
carefully and keep it for future reference.
WARNING! This equipment has been
designed to be installed by qualified
professionals only! There are many factors to
be considered when installing professional
sound reinforcement systems, including
mechanical and electrical considerations, as
well as acoustic coverage and performance.
Mackie Industrial strongly recommends that
this equipment be installed only by a
professional sound installer or contractor.
DX-RVC
Remote Volume Control
Quick-Start Guide
1. Never install, connect, or disconnect the
remote control with the DX8 power supply
on.
2. Before applying power to the DX-RVC, make
sure the wiring is correct as described in
this Quick-Start Guide.
Front Panel Features
UP/DOWN VOLUME CONTROL
Use to adjust the level for the Input,
Output, or Group assigned to the remote
control. Duplicates the function of the UP/
DOWN buttons on the DX8 front panel.
LED DISPLAY
Indicates the level setting of the Input,
Output, or Group assigned to the remote
control. "0" corresponds to "10" on the
DX8 front panel LED display, which is unity
gain. "+10" corresponds to "OL" on the
DX8 front panel LED display, which is
maximum gain.
R20
R21
R22
R23
R24
R25
R26
R27
U5
S1
ON
1
D2
L2 L1
J5
J3
R6
R7
2345678
FUNCTION
C16
U6
R34
R4
D3
C9
D4
C10
R5
J2
A
GND
C7
B
PWR
R35
R1
R2
R3
C14
J4
C3
C4
U2
C8
Rear Panel Features
PREDEFINED FUNCTION SELECTION SWITCH
This 8-position DIP switch provides 256
unique functions that can be assigned to
the DX-RVC remote. Refer to the chart on
the back page for a list of all predefined
functions currently available.
Each remote control must have the
selection switch set to a unique ID. When
the DX8 is first turned on, it polls the
REMOTE BUS
controls connected to it by each unique ID.
Many of the predefined functions have
two ID addresses assigned to it to allow
two remote controls to be connected to a
DX8 that both control the same function.
CONNECTOR (J2)
Connect the wires from the DX8
BUS
wire back about 1/4", insert the wire as
far as it will go into the connector and
tighten down the screw with a small slothead screwdriver.
and identifies the remote
directly to this connector. Strip the
REMOTE
Use a high-quality three-conductor
shielded cable to make this connection,
such as Belden 8451, 9451, or equivalent.
The connector is wired as follows:
Remote DX8
GND G (Ground)
A + (+ Data with +24V DC power)
B – (– Data with +24V DC power)
PWR N/C (This is for an external
power supply, described in
the next section)
DX8 DX-RVC
R5
J2
L2 L1
A
GND
A
GND
Using an External Power
Supply
The DX-RVC is powered by the DX8 over the
data lines. An external power supply can be
used by removing jumpers J3 and J5 from the
DX-RVC circuit board, and connecting a power
supply rated at 9 to 16V AC or DC to the PWR
terminal on the connector (J2). A number of
"wall-warts" or bell transformers are readily
available from local electrical supply houses
with output ratings between 9V and 16V.
Allow 25mA per remote.
From DX8
Installing the DX-RVC
The DX-RVC can be installed in a single
standard electrical box, or in a double-gang
box along with a second DX-RVC or DX-SW4
remote control.
Connecting Multiple Remote
Controls
Up to nine remote controls
can be connected to the DX8
REMOTE BUS
C8
B
PWR
B
length of the cable depends on
the type of cable used and the
number and type of remote
controls used in the system.
As a general rule, using 22
gauge wire (at 0.014 Ω /ft. and
34 pF/ft.), one remote can be up
to 3000 feet away, five remotes
can be up to 2500 feet away,
and eight remotes can be up to 500 feet away
before transmission losses become a factor.
Feet of Cable versus
Maximum Number of 2-Button Remotes
10
9
8
7
6
5
4
3
2
1
Number of 2-Button Remotes
0
0
250
500
750
Belden 8451 (22 AWG, 34pf/ft)
Belden 1192A (24 AWG, 39pf/ft)
Distance Chart for DX-RVC Cable
To Next Remote
. The maximum
1000
1250
1500
1750
Feet of Cable
2000
2250
2500
2750
3000
3250
Total Distance Dependent on Type of Cable Used