Lucent Technologies P118LX, P118SX User Manual

Lucent Technologies
Installation Guide
Cajun P118SX/LX
STACKABLE ETHERNET SWITCH
Cat No. 130010 Rev.0 December 1998
Preface
Important information
CAUTION – TO REDUCE THE RISK OF ELECTRIC SHOCK AND FIRE
1.All servicing should be undertaken ONLY by qualified personnel. The parts inside the unit CANNOT be serviced or repaired by the end user. Please call your service representative for assistance.
2.Do NOT plug in, turn on or attempt to operate a damaged unit.
3.Ensure that the chassis ventilation slots in the unit are NOT BLOCKED.
4.Replace a “blown” fuse only with the same type and rating as is marked on the safety label
adjacent to the power inlet housing the fuse.
5.DO NOT operate the unit in a location where the maximum ambient temperature exceeds 50ºC.
6.Be sure to unplug the power supply cord from the wall socket BEFORE attempting to remove and/or check the main power fuse.

PRECAUTIONS DE SECURITÉ

AVERTISSEMENT – POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE ET D’INCENDIE
1.Tout entretien doit être fait UNIQUEMENT par un personnel de service qualifié. Aucun élément ne peut être réparé par un particulier.
2.NE PAS brancher, allumer ou essayer de faire fonctionner une unité sur laquelle un doute existe quant à son bon fonctionnement.
3.S’assurer que les ouvertures d’aération du châssis dans l’appareil NE SONT PAS OBSTRUEES..
4.Remplacer un fusible défaillant UNIQUEMENT par un modèle du même type suivant les recommandations indiquées sur l’étiquette de securité posée dans le logement du fusible.
5.NE PAS faire fonctionner l’appareil dans un endroit où la temperature dépasse les 50ºC.
6.S’assurer de débrancher l’alimentation électrique AVANT toute manipulation sur le fusible principal.

SICHERHEITSVORKEHRUNG

ACHTUNG – ZUR VERHINDERUNG DES RISIKOS VON ELEKTRISCHEM SCHLAG UND FEUER
1.Die Geräte enthalten keine Bauteile, die außerhalb des Madge Servicezentrums gewartet oder repariert werden können. Die Wartung darf NUR von qualifiziertem, technischem Personal durchgeführt werden.
2.NIEMALS ein beschädigtes Gerät einschalten, oder versuchen es zu bedienen.
3.Vergewissern Sie sich, dass die Chassis Ventilationsöffnungen des Gerätes NICHT BLOCKIERT sind.
Cajun P118 Installation Guide i
Preface Safety Instructions
4.Austauschen einer durchgebrannten Sicherung NUR mit der gleichen Sorte und Belastbarkeit wie sie auf der Sicherheitsaufschrift markiert ist. Die Aufschrift befindet sich neben der Stromzufuhr wo sich auch der Sicherungskasten befindet.
5.Bedienen Sie das Gerät NICHT an einer Stelle an der die Umgebungstemperatur 50ºC
übersteigt.
6.Ziehen Sie das Netzkabel raus, BEVOR Sie versuchen die Hauptsicherung zu kontrollieren oder auszutauschen.
ii Cajun P118 Installation Guide
Preface Safety Instructions

Regulatory Approvals and Safety Information for the Cajun P118SX/LX Products

LASER SAFETY

The Cajun P118SX multi-mode transceiver and the Cajun P118LX single mode transceiver are a Class 1 laser product.
They comply with IEC 825-1 and Food and Drug Administration (FDA) 21 CFR
1040.10 and 1040.11. The transceivers must be operated under recommended operating conditions.

LASER CLASSIFICATION

Class 1 lasers are inherently safe under reasonably foreseeable conditions of operation.
Caution: The use of optical instruments with this product will increase eye hazard.

USAGE RESTRICTION

The optical ports of the module must be terminated with an optical connector or a dust plug.

LASER DATA

Cajun P118SX :

Wavelength:850 nm Output power dissipation : Max. 0.63W

Cajun P118LX :

Wavelength:1300 nm Output power dissipation : Max. 0.68W
CLASS 1
LASER PRODUCT
Cajun P118 Installation Guide iii
Chapter 1
Overview
This guide is divided into the following main sections:
Overview: A general description of the features of the Cajun™ P118. Installation: Instructions for getting the Cajun P118 and Cajun P110 stack up and running.
Cajun P118 Installation Guide 1
Chapter 1 Overview

Description

The Cajun P118SX and P118LX are part of the Cajun P110 family of switches. The
Cajun P110 family is composed of high-performance stackable switches which may be used singly or stacked in any combination.
The Cajun P118 has eight Ethernet/Fast Ethernet (10/100BASE-T) ports and two
Gigabit Ethernet (1000BASE-X) ports. The 10/100 Mbps ports are typically used for workgroup connectivity, while the two 1000 Mbps ports can be used as full duplex uplinks to a Cajun M400, P550, M770 Switch or another Cajun P110 switch or to any other Gigabit Ethernet switch.
The Giga Ethernet ports comply with the IEEE 802.3x Flow Control and IEEE
802.1Q for Tagging Mode standards. All 10/100 Mbps ports can run at full or half duplex Ethernet. A redundant power supply may be used for enhanced fault tolerance.
The Cajun P118 can operate standalone or as part of a stack. A stack can be made up of
any combination of two, three or four Cajun P110 switches, and up 32,000 MAC addresses per stack are supported. A stack requires a Cajun P110 NMA to link the
switches. The units are physically linked using the Exoplane™.
Note: You need to install a Cajun P110 NMA in the P118SX and P118LX switches in
order to operate them in stand-alone mode.
The Cajun P118 can use an advanced flow control mechanism to eliminate packet loss.
An automatic fairness mechanism ensures that all ports gain fair access to the Exoplane even at very high network utilization. Congestion management works both on full and half duplex ports, and ensures no packet loss should the buffers become saturated during peak load conditions.
A redundant power supply (Cajun P110 BUPS) may be used for additional fault
tolerance. The Cajun P118 switch is manageable under CajunView,™ Lucent’s family of SNMP
network management systems, or any other SNMP-based management system, and may be monitored using Lucent’s SMONMaster™ Switch Monitoring Application.
Note: The P118SX and P118LX switches are identical except that the P118LX
module has single-mode fiber ports. Therefore this Installation Guide will only refer to the Cajun P118 unless there are differences in the operation of the switches.
2 Cajun P118 Installation Guide

Fiber Optic Specifications

Two auto-negotiation 1000Base-X ports.

P118SX

1000Base-SX ports
220m over 62.5 µm MMF or
550m over 50 µm MMF.

P118LX

1000Base-LX ports
5 km over SMF or
550m over MMF with special patch cord.
Chapter 2 Preliminary Settings
Cajun P118 Installation Guide 3
Chapter 2
Installation

Default Values

Note: The management-set default values are those defined in Cajun P110 NMA
Parameter Default Value Change Via…
Gigabit Ethernet ports (1,2)
IEEE 802.1Q VLAN Tagging Enabled DIP switches or management* Default VLAN 255§ (Global) Management only
Auto Negotiation Disabled DIP switches or management VLAN Binding** All Management only IEEE 802.3x Flow Control Symmetric Pause Management only
agent version 8.6. If you download or install a later version of the agent software, please refer to the Cajun P110 NMA Release Notes for any changes.
Before you install the Cajun P118, check Table 1 which shows the default values for key parameters and how you can change them.
The default values are set at the factory to enable smooth interoperability with other members of the Cajun Campus (P118, M400, M770, and P550).
Table 1 Default Values
10/100 Mbps ports (3-10)
Flow Control (proprietary) On Management only Speed (10/100) 100 Mbps DIP switches or management Auto Negotiation Off Management only
* Management refers to CajunView, Cajun P110 Manager or the Cajun P110 NMA configuration screens. Please refer to the appropriate documentation for details.
**When using the Gigabit Ethernet ports for backbone connections, set the VLAN Binding Method to ALL. When using the Gigabit Ethernet ports for other applications set the VLAN Binding method to Static Binding.
§ Please refer to the included VLAN Application Note .
Cajun P118 Installation Guide 5
Chapter 2 Installation

Setting the DIP switches

First, set the DIP switches. The position of the switches depends on the Cajun P110
application. The drawing below shows the default positions of the DIP switches on the rear panel of the Cajun P110 switch.
Figure 1 The Cajun P118 Rear Panel Showing the DIP Switches in
Their Default Positions
USE SWITCH
AUTO-NEG.1
TAG 1
AUTO-NEG.2
TAG 2
345678910
ON
10 100
Note: The DIP switches described below function only when the USE SWITCH
switch is in the ON position.
USE SWITCH – Selects whether the Cajun P118 switch configuration will be
controlled by the DIP switches or from the management station.
-ON: certain Cajun P110 switch settings are determined by the DIP switches, and can only be monitored, but not changed, by the console.
-OFF: the DIP switch settings are ignored and the Cajun P110 functionality is controlled from the console via the Cajun P110 NMA. Set to ON when you don’t have SNMP management, or when you want to ensure that the settings will not be changed.
10/100 (eight switches) – Sets the speed for each of the Ethernet/Fast Ethernet
ports.
-When set to on, the port operates at 10 Mbps.
-When set to off the port operates at 100 Mbps.
AUTO-NEG.1, AUTO-NEG-2 – Giga Ethernet Auto-negotiation (AUTO-NEG.1
is for port 1 and AUTO-NEG.2 is for port 2):
-ON: Auto-negotiation is enabled.
-OFF: Auto-negotiation is disabled.
6 Cajun P118 Installation Guide
Chapter 2 Installation
TAG 1, TAG 2 –802.1Q VLAN Tagging mode (TAG 1 is for port 1 and TAG 2 is
for port 2). VLAN Tagging transfers across the backbone packets with VLAN and priority. By carrying this information across the inter-switch link, VLAN Tagging makes it possible to distribute VLANs across the organization. This tagging facility allows you to make two 802.1Q-compliant hubs act as a single logical device.
-ON: IEEE 802.1Q VLAN Tagging is enabled.
-OFF: IEEE 802,1Q VLAN Tagging is disabled for transmit and receive (“Legacy” VLAN per port mode).
If the settings of an existing Cajun P110 stack are changed, the stack must be reset. Press and hold both buttons on the front panel simultaneously for a second or more to reset the entire Cajun P110 stack. In a Reset, all LED indicators turn on. Pressing Reset does not affect configuration settings.
Once you have set the switches, you may proceed with the physical installation of the switch.
Note: Flow Control for the Giga Ethernet ports is configured from the management
station..
Table 2 DIP Switches on the Cajun P118
Switch Function Down (OFF/100) UP (ON/10) USE SWITCH Selection of
operational mode
Giga Ethernet ports only (1-2) TAG 1
TAG 2 AUTO-NEG.1
IEEE 802.1Q VLAN Tagging mode
Auto-negotiation Disabled Enabled
AUTO-NEG.2 10/100BASE-T ports only (3-10) 10/100 (3-10) Speed of 10/100 Mbps
ports
The default position for the DIP switches is indicated by a shaded background.
Port parameters configured via management software
DIP switches used to configure port parameters
(switches ignored).
Disabled (“Legacy”
Enabled
mode)
100 Mbps 10 Mbps
Cajun P118 Installation Guide 7
Chapter 2 Installation

Installing the Cajun P118

The procedure for getting the Cajun P118 up and running depends on whether the switch is to operate standalone or as part of a stack.
First, attach the adhesive rubber legs to the base of the Cajun P110 switch. If the switch is to be rack mounted, do not attach the legs.
Standalone Operation - Plug ‘n’ Play
Getting the Cajun P110 switch working is quick and easy:
1.Connect the power cable to the switch.
2.Connect the cables to the front panel ports.
Note: If you are operating the Cajun P118 in stand-alone mode, you must insert a Cajun P110 NMA agent. Please refer to the Cajun P110 NMA Installation Guide for details..
3.The switch is now fully operational. By default, all 10/100 ports will operate in half duplex mode.

Stacking Operation

If you are using the Cajun P118 as part of a stack, you only need one Cajun P110 NMA for the entire stack.
If there is a Cajun P110 NMA already in the stack then ensure it is in the topmost
Cajun P110 switch and remove the additional NMA. If there is no NMA in the stack then place the Cajun P118 at the top of the stack.
To check what software version you have, see the agent configuration window in MultiMan (on UNIX) or Cajun P110 Manager (on Windows), or see the setup main menu of the Cajun P110 NMA.
1.Before adding a switch to the Cajun P110 stack, turn off the main power to the stack, by individually switching off each hub
2.Place the Cajun P110 NMA in the top switch of the stack
3.If the Cajun P110 NMA contains agent software version 8.6 or higher, go to step 5.
4.If the Cajun P110 NMA does not contain the agent software version 8.6, you should perform a software download of the latest version. The software is on the diskette that came with the Cajun P118. Download is performed via TFTP using a Terminal console or via the timed Download application from your management
station– details can be found in the Cajun P110 NMA installation Guide.
5.Place the Cajun P118 switch in the stack. The Cajun P110 NMA must be in the top switch of the stack. To ensure proper ventilation, ensure that all empty Cajun P110 NMA slots in the
stack are closed.
8 Cajun P118 Installation Guide
Chapter 2 Installation
6.Connect Cajun P110 switches using the Exoplane cables, as shown in Figure 2. A switch connects to its upper neighbor through two Exoplane cable, and to its lower neighbor through another two Exoplane cables. Make sure you securely fasten the cables to the connectors.
Cabling Requirements:
For correct operation, the Cajun P110 Exoplane must be fully connected, with all
units powered up. In case units are stacked, the Cajun P110 NMA must be installed and connected to the Exoplane. Failure to observe this requirement will cause the Cajun P110 units to block all traffic on attached stations and segments.
When using the Cajun P114T or Cajun P114F in the stack, make sure all switches
in the stack are connected using Exoplane cables. Extra cables can be ordered from your local Lucent representative.
Figure 2 Rear view of a Cajun P110 switch stack, showing how the switches are linked via
the Exoplane cables. A Cajun P110 NMA resides in the uppermost switch.
7.Two terminators are supplied with the Cajun P110 NMA. Insert the two terminators into the lowest two connectors at the bottom of the stack, as shown in Figure 2.
8.Turn on the mains power to the stack, by individually switching on each hub.
9.Connect the cables to the front panel ports.
Cajun P118 Installation Guide 9
Chapter 2 Installation
Notes:
If Cajun P110 NMA in the stack contains the software version 8.6 or higher (as
specified in the Cajun P118 Release Notes) or higher, the stack is now fully operational
When a new version of agent software becomes available, you should perform
software download to benefit from the extra capabilities provided. Please refer to the Cajun P110 NMA Installation Guide for details.
10 Cajun P118 Installation Guide

Rack Mounting

Cajun P110 switches slot into a standard 19 inch rack. Remove the rubber legs from the base of any switch that is to be rack mounted.
Place the switches in the rack, and then connect the Exoplane, as follows:
1.Snap open the ends of the front panel to reveal the fixing holes.
2.Slot the switch into the rack. Insert the switches into the rack so that the switches
3.Secure the switch in the rack using the screws. Use one screw on each side. Do not
4.Connect the Exoplane cables, as described above, and as illustrated in Figure 2.
5.Snap closed the hinged ends of the front panel.
Figure 3 Cajun P110 rack mounting arrangement
Chapter 2 Installation
in a logical stack lie directly on top of each other. Ensure that the Cajun P110 screw holes are aligned with the rack hole positions exactly as shown in figure 3. Stacking them in this way will allow the switches to be easily connected using the Exoplane cables.
overtighten the screws to avoid damaging the plastic.
Cajun P118 Installation Guide 11
Chapter 2 Installation

Diagnostics

Table 3 and Table 4 explain the meaning of the Cajun P118 diagnostic LED indicators.
Figure 4 The Cajun P118 Front Panel LEDs and Buttons
Table 3 Meaning of the Cajun P118 Front Panel Buttons
Button Function Meaning
Select The buttons determine what function will be displayed by the 18 Port
LEDs (the top two rows of LEDs). The seven Function LEDs (above the Select buttons) show which
function is currently displayed by the Port LEDs. The Port LEDs can display either Link, Collision, Transmit, Receive, Full Duplex, Flow Control or ISL.
If, for example, the Link (LNK) LED is lit, then LEDs 1 to 18 will display the Link status of every port.
Press the left or right button to toggle the Port LED display between functions
Reset Press and hold both buttons simultaneously for a second or more to
reset the entire Cajun P110 stack. In a Reset, all LED indicators turn on. Pressing Reset does not affect configuration settings.
12 Cajun P118 Installation Guide
Table 4 Meaning of the Cajun P118 front panel LEDs
LED Indicator Function Status Meaning
Chapter 2 Installation
PWR Power OFF
ON Blink
NMA Agent OFF
ON
Mains power not connected Mains power connected Working on back-up power supply
No agent in switch
Switch contains an active agent RED NMA N/A Function LED
LNK
COL
Tx
Rx
FDX
FC
100M
/LQNVWDWXV 2))
2
&ROOLVLRQ
7UDQVPLWWR OLQH
5HFHLYH IURPOLQH
3
+DOI)XOO GXSOH[
)ORZ &RQWURO
4
Port speed OFF
3RUW/('
21
Blink once Blink twice
OFF ON
OFF ON
OFF ON
OFF ON
ON OFF
ON
3RUW'LVDEOHG
3RUWLVHQDEOHGDQGOLQNLV2.
Link Test Fail.
Partition
No Collision
Collision occurred on line
No activity
Data transmitted
No activity
Data Received
Half duplex connection to port.
Full duplex connection to port.
Flow Control enabled
Flow Control disabled
Port operating at 10 Mbps
Port operating at 100 Mbps
1
.
Notes:
1.The LED blinks once or twice every five seconds in the event of an error.
2.The COL LED is always OFF for ports 1 and 2.
3.The FDX LED is always ON for ports 1 and 2
4.The 100M LED is always OFF for ports 1 and 2.
Cajun P118 Installation Guide 13
Lucent Technologies Inc.,
'DWD1HWZRUNLQJ6\VWHPV 0W$LU\5G%DVNLQJ5LGJH
NJ 07920.
Cajun and CajunView are trademarks, and in some jurisdictions may be registered trademarks of Lucent Technologies or its affiliated companies. Other trademarks appearing in this document are the property of their respective owners.
© Copyright 1998 Lucent Technologies. All rights reserved.
Loading...