Time: 20 Minutes
Hand Tools Skills - Easy
BAS IC I NST ALL AT ION G UI DE
BASIC SYSTEM SETUP
STEP 1
CONTINUED
LH600 Access Series
1
Connect the BNC cameras to the
BNC ports on the rear panel.
Connecting Cameras (not included)
NOTE: Test the cameras prior to
selecting a permanent mounting
location by temporarily connecting
the cameras and cables to your
system.
2
Connecting the USB Mouse
(not included)
Connect a USB mouse to the
USB port on the rear panel of
the system.
3a
Connecting a Monitor
5
Connecting the Power Cable
Connect the power cable to the
DC 12V port on the rear panel of
the system; connect the power
adaptor to an outlet, power strip,
or surge protector. Wait for the
system to boot up into the main
screen.
From the Monitor-OUT BNC port
connect a BNC terminated cable
to the RCA OUT of the LCD
monitor (not included).
OR
1
Mouse
1
2
3
Direction Pad
3
Use the direction pad to
navigate thrrough the
system menus.
LH600 Series Quick Setup Guide - English - R1
1 x Digital Video Recorder with pre-installed HDD*
1 x Power Adapter
1 x Remote Control
1 x Mouse
1 x Ethernet Cable
1 x DVI to VGA Adapter
1 x User Manual
1 x Quick Start Guide
1 x Software CD
The Quick menu gives you an overview of all
the available settings on your DVR.
To open Quick Menu:
1. Right-click anywhere on the screen in
the main viewing window OR
2. Press the MENU button on the front panel.
NOTE: If you are configuring the system, you
cannot open Quick menu.
Quick Menu (Mouse option only)
6
Main Menu
Right click anywhere on the monitor screen and from the QUICK
menu, select SYSTEM SETUP to access the MAIN MENU options.
2
1. DISPLAY
2. CAMERA
3. SOUND
4. SYSTEM
5. EVENT/SENSOR
6. DISK MANAGE
Powering On/Off the System
To power on the system:
1. Press the POWER button on the remote
control or front panel. The system powers
on. Wait for the system to boot up into the
main screen. By default, the system
begins recording continuously from any
connected cameras.
To power off the system:
1. Press the POWER button on the front panel
of the system. A confirmation window opens.
2. Click YES to shut down the system. OR
3. Right-click anywhere on the screen. The Quick
Menu opens.
4. Click SHUTDOWN. A confirmation window opens.
5. Click YES to shut down the system.
ATTENTION:
• * Number of Channel s/ Port configur ation and HDD (hard disk dr ive)
capacity may v ary by model. Ch eck your package for s pecific content
information.
• Monitor and Camer as are not included.
• Broadband Router a nd Computer are requ ired for local and rem ote
monitoring (not inc luded).
Connect the included DVI to
VGA adapter to the DVI port at
the back of the DVR. Connect
the VGA/DVI Cable from the LCD
monitor (not included) to the
VGA/DVI adapter.
3b
3b
4
Connecting the Ethernet Cable
Connect one end of the Ethernet
cable (for remote monitoring) to
one of the router’s (not included)
LAN ports and the other end to
the DVR’s Network Port.
Connect one end of the monitor’s power cable to its power port and the
other end to the power outlet. Press the DISPLAY button at the front
panel of the DVR repeatedly until you reach the desired display mode
(i.e. full screen, quad, auto-sequence).
Tip: Adjust the contrast and brightness of your
monitor and the camera(s) color settings to
optimize the image quality.
1. Right-click anywhere on in the
main viewing window to open the
Quick menu.
2. Click SYSTEM SETUP. The System
Setup window opens.
3. Click
SYSTEM. The System
window opens.
4. Beside DATE TIME, click on the
time (yyyy/mm/dd; hh/mm/ss)
and adjust the values using the
buttons.
OR
• Double-click the values to open
the number window to input the
values.
5. Beside DATE FORMAT, use the
button to adjust the date format.
6. Click APPLY to save your settings.
7
NOTE: It is highly recommended
to set the time on the system
prior to doing any recording. All
recording must be stopped on
the system in order to set the
time.
Setting the Date & Time
SET-UP LOCAL VIEWING ON YOUR
PC
The system automatically opens the
virtual keyboard when you doubleclick a blank field, or when you need
to enter system information.
The Virtual Keyboard
Default
USER ID : ADMIN
(case sensitive)
PASSWORD: 1234
TIP: It is recommended to change
the default password after the initial
setup is complete.
To use the Virtual Keyboard:
1. Click any desired letter, number, or character.
NOTE: Click “A” to shift between upper and lowercase letters.
For detailed setup information, please refer to
your included User’s Manual. For additional
information, please visit our website
www.lorextechnology.com
Information in this document is s ubject to ch ange w ithout notice. As o ur
products are subjec t to continuous improvement , Lorex Technology INC. and
our subsidiari es reserve the right to mo dify prod uct design, sp ecifications
and prices, without notice and with out incurring any obligation . E&OE © 2010
LOREX. All r ights reser ved.
* For setup of Instant Mobile Viewing
and MAC Compatibility refer to your
User Manual.
Congratulations! You have completed STEP 1 & 2 successfully. Your system is now
ready to use. Refer to the owner’s manual to learn how to record, search, playback,
and use other advanced features and all other features available with this system.
OPTIONAL
Instant
Mobile
Viewing
1
1. Launch Internet Explorer.
2. In the address bar, enter the
IP address of your System
recorded in the previous
step.
NOTE: Enter http:// followed by
the IP address of your system,
then a semi-colon, and then
the HTTP Port number (i.e.
http://192.168.X.XXX:80).
2
1. Right-click in the main
viewing window to open
the Quick Menu.
2. Click SYSTEM SETUP>
SYSTEM>SYSTEM
MANAGEMENT
3. Beside SYSTEM
INFORMATION, click
the PRESS button.
4
Left-Button: While in a split-screen display
mode, double-click an individual channel
to view it in full-screen; double-click again
to return to the split-screen display mode.
While navigating menus, click to select a
menu option. Right-Button: Right-click
anywhere on the screen to open the Quick
Menu. Scroll-Wheel: N/A
Enter in your System’s User ID and Password.
USER ID: ADMIN, PASSWORD: 1234. The Web Remote Viewer
window opens.
3
Click the Active X menu bar near the top of the browser. Click Install
ActiveX Control.
4
Click Install when the security window opens.
5
Click the ActiveX toolbar when the main Web Remote Viewer
window opens. Click Install ActiveX Control.
6
Click Install when the security
window opens. The Web Remote
Viewer automatically detects and
connects to your system after the
ActiveX plug-in installs.
7
http://your local IP address
EXAMPLE
LOCAL LIVE SITE
By default, the system does not require a password to login.
STEP 3A