Why Buy A Lopi Pellet Stove?
Convenience
Lopi pellet stoves and inserts offer a clean and
environmentally sound way to heat your home.
There are no insects, dirt, pieces of bark
or slivers of wood brought into your home
with pellet fuel.
Pellet s f or your Lopi pellet appliance also take
up less space to store than cordwood or woodchips.
You can s tore four times the amount of pellet fuel in the
same space that wood takes up! A winter’s supply of
pelle ts for the average home occupies about 6’ x 6’
x 6’ of space so you can store them in any dry area such as a
basement, utility room or shed.
Your Lopi pellet appliance only needs to be loaded once a day.
Nothing could be easier. It will automatically feed the correct
amount of pellets to keep your home warm all day and night.
Pioneer
Use the wall thermostat (standard on all large models) or the
optional remote control and extend the burn time even longer.
Set the thermostat to your desired room temperature and the
pellet appliance will cycle on and off to maintain the temperature
and extend the value of your fuel.
Efficiency
Pellets are an all-natural, renewable fuel. They are held together
by lignin, which is a natural substance occurring in wood fibers
that acts as a glue when compressed. It’s so safe, it’s also used
as a binding agent in animal feed pellets.
Pellets fuel has been proven to be the cleanest burning type of
wood fuel you can use. The U.S. EPA woodburning limit of
particulates is 7.5 grams per hour - but Lopi pellet stoves only
exhaust on average 1.2 grams per hour! This is truly a fuel
source as good for the environment as it is for you.
Confidence
Your Lopi appliance is designed, engineered and built to the
highest standards in the world. We do not cut corners to save
costs, we only use the highest quality materials, heavy-duty steel
and high-tech tested components in our Lopi pellet appliances.
And we stand behind our appliances with our “REA L WOR LD”
Limited Seven Year Warranty (see www.lopifire.com).
Yankee
Pioneer Bay
Yankee Bay
Large
Capacity
Hopper
Fueling your pellet stove or insert has never been easier. The
entire top of the stove or insert lifts up to allow access to the
hopper. When full, your pellet appliance will provide you with
many hours of uninterrupted heating. The large capacity of the
freestanding stoves also means you don’t have to wait until the
hopper is empty before refueling with a full bag of pellets.
Easy
Access
All Lopi pellet appliances are designed for easy maintenance.
The swing-out door allows quick access to the firebox for
cleaning and yearly maintenance.
Huge
Ash Pan
Designed as part of the pedestal on the stoves, the huge
ash pan allows for significantly greater time between ash
removal. A simple handle above the ash pan allows
accumulated ashes to be removed from the firebox without
opening the door. The inserts are equipped with an easy
pull out ash pan located beneath the door.
Automatic
Operation
Operate your pellet appliance automatically. Add a wall thermostat
or remote control thermostat for the ultimate in hands-free operation.
You simply set the thermost at to the desired temperature and the
pellet stove will do the rest. The wall thermostat is standard on all
Yankee models.
If you choose to operate your pellet appliance manually, simply set
the feed rates and push the start button to activate the auto igniter.
Within minutes your pellet appliance is in full operation.
Installation Information
Freestanding Clearances to
Unprotected Combustible Walls
Stove clearances measured from stove top. Connector clearances
measured from the flue pipe.
A
D
E
A
A
B
B
G
C
C
D
E
C
C
Minimum Clearances To Combustibles:
Unit To Backwall A - Min. 3” A - Min. 3”
Unit To Sidewall B - Min. 9” B - Min. 9”
Front Hearth
Extension C - Min. 6” C - Min. 6”
Connector Tee
to Rear of Hearth D - Min. 2” D - Min. 2”
Corner of Unit
To Wall E - Min. 2” E - Min. 3”
Connector Tee
to Wall F - Min. 3” F - Min. 3”
Hearth Pad* G - Min. 21 5/8” Wide G - Min. 25” Wide
* The pellet stove must be installed on a non-combustible floor protector
which is a minimum .018” thick - 26 gauge.
ALCOVE REQUIREMENTS
Minimum Height 60” 60”
Maximum Depth 48” 48”
Minimum Width 42” 43”
E
D
G
Pioneer Yankee
x 26 7/8” Deep x 29” Deep
Pioneer Yankee
F
B
B
C
C
A
F
E
C
C
F
E
D
E
Insert Clearances to
Unprotected Combustibles
Mantle:
combustible
or non-combustible
B
A
C
G
D
H
I
E
Minimum Clearances To Combustibles:
Pioneer Bay Yankee Bay
A - Min. 32”
(10” from hopper lid)
B - Min. 35”
(13” from hopper lid)
C - Min. 34 1/8”
(6” from hopper lid)
D - Min. 15 1/2”*
(6” from door opening)
E - Min. 34 1/8”*
(6” from door opening)
F - 9” F - 8 3/4”
(to side combustible) (to side combustible)
* The pellet insert must be installed on a non-combustible floor protector which is
a minimum .018” thick - 26 gauge.
Fireplace Minimum Dimensions:
G - 19 5/8”
H - 30”
(includes circuit board)
I - 16 5/8”
(includes 5” for vent)
Installation:
J - The vent should be routed to the fireplace prior to installing the I
- insert. See Owner’s Manual for details on vent location.
K - The insert must protrude 9 3/8” (Pioneer Bay) 12” (Yankee Bay)
onto the hearth for the panels to fit correctly.
Surround Panels:
Pioneer Bay Yankee Bay
Rectangular Panels:
8" x 10" Panels
28 7/8"H x 40 1/2"W
10" x 13" Panels
31 7/8"H x 44 1/2"W
Rectangular Panels:
8" x 10" Panels
32"H x 45"W
J
F
K
A - Min. 32 3/4”
(6 1/4” from hopper lid)
B - Min. 33” to 38”
Depending on mantle depth
See Owner’s Manual for details
C - Min. 42”
(7” from hopper lid)
D - Min. 18”*
(6” from door opening)
E - Min. 36”*
(6” from door opening)
G - 20” to 25 3/4”
height - See Owner’s Manual for details
H - 36”
(includes circuit board)
I - 14”
(includes 5” for vent)
depending on hopper
TESTING
Pioneer and Pioneer Bay safety tested and certified by Warnock Hersey. Yankee and Yankee Bay safety tested and certified by Omni-Test L aboratories.
All models tested to UL 1482-94/ULC S627-93/CSA B366.2/ASTM E 1509-95.
These pellet fired appliances have been tested and listed for use in manufactured homes in accordance with Oregon Administrative Rules 814-23-900
through 814-23-909.