WARNING:If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
Burner
Report # 028–S–28-5
ANSI Z21.88,
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
-Ins tallat ion and s er v ic e m us t be per form ed by a qualified ins taller , ser v ic e agenc y or the gas
supplier.
This appliance may be installed as an OEM installation in a manufactured (mobile) home and
must be installed in accordance with the manufacturer’s instructions and the manufactured
home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in
Mobile Homes, CAN/CSA Z240 MH.
This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
Berkshire Owner’s Manual
Installer:After installation give this manual to the home-owner
and explain operation of this heater.
Copyright 200
7, T.I. $10.00 100-01159 4040621
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
2Introduction
Introduction
We welcome you as a new owner of a Lopi Berkshire stove. In purchasing a Berkshire you have joined
the growing ranks of concerned individuals whose selection of an energy system reflects both a
concern for the environment and aesthetics. The Berkshire is one of the finest home heaters the
world over. This manual will explain the installation, operation, and maintenance of this stove. Please
familiarize yourself with the Owner's Manual before operating your heater and save the manual for
future reference. Included are helpful hints and suggestions that will make the operation and
maintenance of your new stove an easier and more enjoyable experience. We offer our continual
support and guidance to help you achieve the maximum benefit and enjoyment from your heater.
Important Information
No other Berkshire Stove has the same serial number
as yours. The serial number is on the listing plate
chained to the gas control valve.
This serial number will be needed in case you require
service of any type.
Model: Lopi Berkshire Stove
Serial Number:
Purchase Date:
Purchased From:
Mail your Warranty Card
Today, and Save Your Bill of
Sale.
To receive full warranty coverage,
you will need to show evidence of
the date you purchased your
heater. Do not mail your Bill of
Sale to us.
We suggest that you attach your
Bill of Sale to this page so that you
will have all the information you
need in one place should the need
for service or information occur.
Travis Industries100-011594040621
Table of Contents3
Introduction
Introduction & Important Information................2
* Do not light any appliance
* Extinguish any open flame
* Do not touch any electrical switch or plug or unplug anything
* Open windows and vacate building
* Call gas supplier from neighbor's house, if not reached, call fire
department
•This unit must be installed by a qualified installer to prevent the
possibility of an explosion. Your dealer will know the requirements in
your area and can inform you of those people considered qualified.
The room heater should be inspected before use and at least annually
by a qualified service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, etc.
•The instructions in this manual must be strictly adhered to. Do not use makeshift
methods or compromise in the installation. Improper installation will void the warranty
and safety listing.
Look for this label:
For LPG only | Pout 11” W.C.
If the label is present, the
heater is equipped for LP
(propane). If the label is
absent, the heater is equipped
for NG (natural gas).
•This heater is either approved for natural
gas (NG) or for propane (LP or LPG).
Burning the incorrect fuel will void the
warranty and safety listing and may cause
an extreme safety hazard. Direct
questions about the type of fuel used to
your dealer. Check for the label shown to
the right.
Ok
Gas
•Contact your local building
officials to obtain a permit
and information on any
installation restrictions or
inspection requirements in
your area. Notify your
insurance company of this
heater as well.
•It is imperative that control
compartments, screens, or
circulating air passageways
of the heater be kept clean
and free of obstructions.
These areas provide the air
necessary for safe
operation.
•Do not store or use gasoline
or other flammable liquids in
the vicinity of this heater.
?
• If the flame becomes sooty,
dark orange in color, or
extremely tall, do not
operate the heater. Call
your dealer and arrange for
proper servicing.
• Do not operate the heater if
it is not operating properly in
any fashion or if you are
uncertain. Call your dealer
for a full explanation of your
heater and what to expect.
• Do not use this appliance if
any part has been under
water. Immediately call a
qualified service technician
to inspect the appliance and
to replace any part of the
control system and any gas
control which has been
under water.
Travis Industries100-011594040621
Safety Precautions5
•Do not place clothing or
other flammable items on or
near the heater. Because
this heater can be controlled
by a thermostat there is a
possibility of the heater
turning on and igniting any
items placed on or near it.
•The viewing glass should be
opened only for lighting the
pilot or conducting service.
•Any safety screen or guard
removed for servicing must
be replaced prior to
operating the heater.
•Do not operate with the
glass removed or damaged.
•Operate the heater
according to the instructions
included in this manual.
•If the main burners do not
start correctly turn the gas
off at the gas control valve
and call your dealer for
service.
• Light the heater using the
built-in piezo igniter. Do not
use matches or any other
external device to light your
heater.
• Never remove, replace,
modify or substitute any part
of the heater unless
instructions are given in this
manual. All other work must
be done by a trained
technician. Don't modify or
replace orifices.
• Allow the heater to cool
before carrying out any
maintenance or cleaning.
• The pilot flame must contact
the thermopile and
thermocouple (see the
illustration to the left). If it
does not, turn the gas
control valve to "OFF" and
call your dealer.
•This unit is not for use with
solid fuel
•Do not place anything inside
the firebox (except the
included fiber logs).
•If the fiber logs become
damaged, replace with
Travis Industries log set.
•Children and adults should
be alerted to the hazards of
high surface temperature
and should stay away to
avoid burns or clothing
ignition. Young children
should be supervised when
they are in the same room as
the heater.
•Instruct everyone in the
house how to shut gas off to
the appliance and at the gas
main shutoff valve. The gas
main shutoff valve is usually
next to the gas meter or
propane tank and requires a
wrench to shut off.
This
Manual
• Do not throw this manual
away. This manual has
important operating and
maintenance instructions
that you will need at a later
time. Always follow the
instructions in this manual.
•Plug the heater into a
120V grounded electrical
outlet. Do not remove the
grounding plug.
•Don’t route the electrical
cord in front of, over, or
under the heater
• Travis Industries, Inc.
grants no warranty,
implied or stated, for
the installation or
maintenance of your
heater, and assumes
no responsibility of any
consequential
damage(s).
Travis Industries100-011594040621
6Specifications
Features:
-Ember Fyre™ Burner for "Wood Fire" Look
-Works During Power Outages (millivolt system)
-High Efficiency
-Optional Thermostat or Remote Control
-Optional Blower for Quicker Heat Distribution
-Convenient Operating Controls
-Variable-Rate Heat Output
-Low Maintenance
Installation Options:
-Freestanding Stove
-Horizontal or Vertical Vent
-Residential or Mobile Home
-Straight or Corner Placement
-Bedroom Approved
Heating Specifications:
Approximate Heating Capacity (in square feet)*............500 - 1,500 with Blower, 500 to 1,200 Without
Maximum Input........................................................................................31,000
Output from Low to High (in BTU’s per hour)..............................................16,608 to 26,815
Steady State Efficiency............................................................................Up to 86.5 %
AFUE (without blower) .............................................................................Up to 72.8 %
•Heating capacity will vary depending on the home’s floor plan, degree of insulation, and the outside
temperature.
** Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system.
Dimensions & Weight:
19"
16-1/8"
4-7/8"
26-3/4"
The flue collar protrudes
7/8" above the stove top
NOTE:
Measure side, corner,
and back clearances
from the stove top.
This heater is shipped in natural gas (NG) configuration but may be converted to propane (LP) using
the included LP conversion kit. The sticker on top of the gas control valve will verify the correct fuel.
Travis Industries100-011594040621
Installation (for qualified installers only)7
Installation Warnings:
!Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
!This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
!This appliance must be installed in accordance with all local codes, if any; if not, in
U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow B-149.
!In Manufactured or Mobile Homes must conform with: In USA, Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280; In Canada, CSA Z240.4
and Gas-Equipped Recreational Vehicles and Mobile Housing. This appliance may
be installed in Manufactured Housing only after the home is site located.
!This stove is designed to operate on natural gas or propane (LP).
!All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
!Notify your insurance company before hooking up this stove.
!The requirements listed below are divided into sections. All requirements must be
met simultaneously. The order of installation is not rigid – the qualified installer
should follow the procedure best suited for the installation.
Packing List
•Propane Conversion Kit
•Log Set
•4” Pipe, 8” Pipe, and 90° Elbow (for gas inlet)
•Glass Latch Tool (to un-latch glass frame)
•Touch-Up Paint
•4 Screws & Clips (Fyrestone only) for stone inserts
• Cover Plate with Knob (for the Aroma-Therapy option)
Installation Overview
See "Vent
Requirements"
Additional Items Required
•Vent (see “Venting Requirements” for details)
•Gas Line Equipment (shutoff valve, pipe, etc.)
Additional Accessories Required
•Enameled Units are shipped without the top and side
inserts - see "Stone or Cast Insert Installation" on page 42.
See
"Clearances"
See "Gas Line
Installation"
See "Floor
Protection
Requirements"
Travis Industries100-011594040621
8Installation (for qualified installers only)
A
Installation Hints:
• If converting to LP, convert the appliance prior to installation.
• The blower is easiest to install prior to installation. Because the blower is located near the gas inlet
location, we recommend using the included pipe and elbow to route the gas inlet around the blower
position.
• Install the logs last - they are fragile.
• When determining the location of the stove, locate the wall studs (for horizontal penetrations) and
ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure
the vent does not intersect with a framing member.
•Fumes and smoke from the paint curing and oil burning off the steel may occur the first time you start
this heater. This is normal. We recommend you open windows to vent the room.
Stove Clearances
Straight InstallationsCorner Installations
With this clearance the
vent is centered 7-1/8"
from the back wall, 23-1/2"
A
from the side wall.
With this clearance, the vent is
centered 15-3/4" from the
wall.
10" Min.
5" Min.
Mobile Home Requirements
•When the stove is installed in a mobile home, it must be bolted to the floor and the appliance
grounded (use the optional blower with a grounded circuit or other suitable grounding method current ANSI/NFPA 70 or CSA C22.1).
5" Min.
45°
Travis Industries100-011594040621
Installation (for qualified installers only)9
Heater Placement Requirements
•Heater must be installed on a level surface capable of supporting the heater and vent
•Due to the high temperature, the heater should be located out of traffic and away from
furniture and draperies.
?When placed in a location where the floor to ceiling height is under 7 feet, the installation
is considered an alcove and must meet the following requirements:
•The alcove floor to ceiling height must be at least 58” tall
•The alcove must not be more than 45” deep before the ceiling returns to 7’
•The alcove must be at least 46-3/4” wide
•The heater must not be placed so the vents below or above the door, along the sides of
heater, or along the back of the heater can become blocked.
•This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Floor Protection Requirements
•When the stove is installed directly on carpeting, vinyl or other combustible material other
than wood flooring or a high pressure laminate wood floor, the stove must be installed on
a metal or wood protection panel extending the full width and depth of the heater
(Minimum 26-3/4” wide by 19” deep).
Make sure these rubber tipped
bolts on each leg contact the floor
(they dampen any noise that may
transmit through the hearth). Do
not adjust with weight on the legs,
the rubber tips may tear.
Travis Industries100-011594040621
10Installation (for qualified installers only)
Gas Line Installation
!The gas line must be installed in accordance with all local codes, if any; if not, follow current ANSI
Z223.1 or NFPA 54 in the USA and the current CGA B149 in Canada.
!The heater and gas control valve must be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPA). For pressures
under 1/2 psig (3.45 kPA), isolate the gas supply piping by closing the manual shutoff valve.
•This heater is designed for natural gas but can be converted to propane. Check the sticker on
top of the gas control valve to verify the correct fuel is used (see page 4).
•Leak test all gas line joints and the gas control valve prior to and after starting the heater.
•The gas inlet accepts a 3/8” F.P.T. Fitting
•The location of the gas inlet is shown below
•A manual shutoff valve is required for installation (it must be located within 3’ of the heater).
T-Handle gas cocks are required in Massachusetts in compliance with code 248CMR.
With the included pipe
installed, the gas inlet is
located at the location
shown below.
Centerline
9-3/4"
8-3/4"
1-3/8"
Gas Inlet Pressure
•With the heater off, the inlet pressure must meet the requirements listed in the table below
•If the pressure is not sufficient, make sure the piping used is large enough and the total gas load
for the residence does not exceed the amount supplied.
•The supply regulator (the regulator that attaches directly to the residence inlet or to the propane
tank) should supply gas at the suggested input pressure listed below. Contact the local gas
supplier if the regulator is at an improper pressure.
!Always maintain the required 1” clearance (air space) to combustible materials to prevent a fire hazard.
Do not fill air spaces with insulation.
!The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it’s own separate vent system.
• This appliance is equipped only for
altitudes 0-2000 feet. However,
our in-house testing has shown
that the unit operated at altitudes to
8000 ft.
!Failure to adjust the air shutter
properly may lead to improper
combustion which can create a
safety hazard. Consult your dealer
or installer if you suspect an
improperly adjusted air shutter.
•When the vent passes through a
wall, a wall thimble is required.
When the vent passes through a
ceiling, a support box or firestop is
required. When the vent passes
through the roof, a roof flashing
and storm collar are required.
Follow the instructions provided
with the vent for installing these
items.
Vertical Termination
use the "high-wind" version (if
applicable)
Use a roof flashing and storm collar
whenever passing through the roof
Use a firestop spacer whenever
passing through a ceiling
8-5/8"
8-5/8"
Minimum
Framing for
wall thimble
Maintain a minimum 1"
clearance from vent to any
combustible.
NOTE: always
Minimum framing
for fire stop
Use a support box
on exposed vent
Use a firestop whenever
passing through a wall
Vertical Vent
Requirements
Maintain a minimum 1"
clearance from vent to
any combustible
Horizontal Vent
Requirements
Horizontal Termination
•Use of of the following 6-5/8" diameter co-axial gas direct vent systems:
ManuafacturerSeries
Simpson Dura-VentModel GS
Selkirk Hearth ProductsDirect-Temp
American Metal ProductsAmeri-Vent
NOTE : Always use the high-wind cap for the type of vent you are using (if applicable)
•Slide the vent sections together and turn 1/4 turn until the sections lock in place.
•Screws are not required to secure the vent. However, three screws may be used to
secure vent sections together if desired.
•High temperature sealant is recommended at the appliance starter section connection
(use high-temperature silicone or Mill-Pac®).
•If disassembly is required, at time of re-assembly check to see if the vent creates a tight
fit. If it does not, apply high temperature sealant to the joints of the affected sections.
•Horizontal sections require a 1/4" rise every 12" of travel
•Horizontal sections require non-combustible support every three feet (e.g.: plumbing
tape)
Travis Industries100-011594040621
12Installation (for qualified installers only)
Approved Vent Configurations
Restrictor Position
•A restrictor is built into the appliance to control the flow rate of exhaust gases. This ensures proper
flames for the wide variety of vent configurations. Depending upon the vent configuration, you may
be required to adjust the restrictor position. The charts for approved vent configurations describe
which position the vent restrictor must be in.
To Adjust the Restrictor
To Access the Restrictor
Lift the stove top off the stove
and place it aside.
Lift the cotter pin out.
NOTE:
The restrictor is
shipped in
position #1.
a
Slide the restrictor
b
adjustment rod in.
Restrictor
Positions
# 5
# 6
# 4
# 1
# 3
# 2
Replace the cotter pin
c
through the correct
hole on the restrictor
adjustment rod.
This restrictor is
in position # 6
Measuring Vent Lengths
Vent Horizontal Run is
measured from the start of
the horizontal section to the
end of the termination.
H2
H1
Vertical Elbow
NOTE:
When a horizontal elbow (90° or 45°) is
used, horizontal length is the sum of the
two lengths (H1 + H2).
Vertical Elbow
Vent Height is calculated to
the top of the vent on
horizontal terminations and
to the top of the termination
on vertical terminations.
Vent
Height
Vent
Horizontal
Run
Horizontal
Elbow
Travis Industries100-011594040621
Installation (for qualified installers only)13
Approved Venting Configurations for Vertical Terminations with
Zero, Two, or Four 45° Elbows
•10’ Minimum System
Height
(with or without offsets)
•40’ Maximum System
Height
•24’ Maximum Offset
•The termination must fall
within the shaded area
shown in the chart. Use
the indicated restrictor
position.
•If using offsets, use the
table below to calculate the
vertical rise and horizontal
offset
Horizontal
Offset
Vertical
Rise
Offset
Length
40' (max)
30 feet
25 feet
20 feet
15 feet
0 feet
5 feet
Restrictor
Position # 6
10 feet
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
Approved Venting Configurations with a Horizontal Termination
and One 90° Elbow
•If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
•The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
19' (max)
15 feet
10 feet
5 feet
0 feet
5 feet
Restrictor Position # 5
NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.
NATURAL GAS: Min. 2' Section Required
PROPANE (LP): Min. 3' Section Required
10 feet
Restrictor
Position # 1
15 feet
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
20 feet
24 ' (max)
19' (max)
15 feet
10 feet
5 feet
0 feet
0 feet
5 feet
10 feet
15 feet
20 feet
0 feet
24 ' (max)
Travis Industries100-011594040621