Longshine LCS-FS9116-B User Manual [en, de, es, fr, it, pl]

Longshine Technologie
Europe GmbH
www.longshine.de
16-Port 10/100Mbps
User’s Manual
English Francais Deutsch Italiano Español Polski
Introduction
The device is a powerful, high-performance Fast Ethernet switch, with all 16 ports capable of 10 or 100Mbps auto-negotiation operation (NWay), which means the switch could automatically negotiate with the connected partners on the network speed and duplex mode. It is ideal for micro-segmenting large networks into smaller, connected subnets for improved performance, enabling the bandwidth demanding multimedia and imaging applications. Moreover, the 10/100Mbps auto-sensing ability provides an easy way to migrate 10Mbps to 100Mbps network with no pain. Compared to the shared 10Mbps or 100Mbps networks, the switch delivers a dedicated 10/100Mbps connection to every attached client with no bandwidth congestion issue. This switch also supports auto MDI / MDI-X function. Each port could be used to connect to another switch or hub with no crossover RJ-45 cable.
Store-and-forward switching mode promises the low latency plus eliminates all the network errors, including runt and CRC error packets. To work under full-duplex mode, transmission and reception of the frames can occur simultaneously without causing collisions as well as double the network bandwidth.
The switch is plug-n-play without any software to configure and also fully compliant with all kinds of network protocols. Moreover, the rich diagnostic LEDs on the front-panel can provide the operating status of individual port and whole system.
Before you start to install the switch, check the following contents in this package
One NWay switch One Power cord User’s manual Rack-mount brackets and screws
(Rack-mount " brackets are optional available for non 19" models)
1
LED Definition
Please refer to the following table for LED definition
10.5-inch Model
19-inch Model
LED Status Operation
Link/Act
REAR Panel
The rear panel is shown as below,
Steady Green Power is on Power Off Power is off Steady Green The port is connected Blinking Green The port is transmitting/receiving data. Off No connection
2
Station Connection
Connect each station to the switch by twisted-pair cable. Plug one RJ-45 connector into a RJ-45 port of the switch, and plug the other RJ-45 connector into the station’s network adapter. Power on the switch and then system is ready. For cable selection, refer to the following table.
Switches Connection
In making a switch interconnection, you could use any port to connect another switch with straight or crossover cable. As all the ports support auto MDI / MDI-X function, using a straight cable to make a switch-to-switch connection is allowed.
For cable selection, refer to the following table
Network Speed Cable Type Max. Length
10Mbps Cat. 3, 4, 5 UTP/STP 100 meters 100Mbps Cat. 5 UTP/STP 100 meters
Rack-Mount
Rack-Mount Installation
The switch may standalone, or may be mounted in a standard 19-inch equipment rack. Rack mounting produces an orderly installation when you have a number of related network devices. The switch is supplied with two optional rack mounting brackets and screws. These are used for rack mounting the unit.
3
Specification
Standard IEEE 802.3 10BASE-T
Interface 16 * 10/100Mbps RJ-45 Fast Ethernet Ports
IEEE 802.3u 100BASE-TX IEEE 802.3x full duplex operation and flow
control
Uplink
Network Speed 10/100Mbps & Full/Half duplex mode auto
MAC Addr. Table 8K MAC entries
Memory 160K bytes Power Supply Internal Power supply
EMI CE and FCC class A
Auto MDI/MDI-XAuto crossover
detection
3.3V 4A (100-240V/ 50-60Hz)
4
FCC Certifications
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
CE Mark Warning
This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the essential protection requirement of Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility.
Company has an on-going policy of upgrading its products and it may be possible that information in this document is not up-to-date. Please check with your local distributors for the latest information. No part of this document can be copied or reproduced in any form without written consent from the company.
Trademarks: All trade names and trademarks are the properties of their respective companies. Copyright © 2005, All Rights Reserved.
5
Introduction
Cet appareil est un interrupteur Fast Ethernet puissant et hautement performant, avec une capacité d’opérations d’auto négociation (Nway) pour ses 16 ports, de 10 ou 100Mbps, ce qui signifie que l’interrupteur est capable de négocier automatiquement avec les partenaires connectés sur la vitesse du réseau et sur le mode bidirectionnel. Il est idéal pour micro-segmenter de vastes réseaux en des sous-réseaux plus petits et connectés entre eux, afin d’en augmenter les performances, ce qui permet les opérations de bande large multimédia et image. De plus, la capacité d’auto-reconnaissance directe 10/100Mbps permet de passer facilement d’un réseau de 10Mbps à 100Mbps. Comparé aux réseaux partagés 10Mbps ou 100Mbps, l’interrupteur fournit une connexion 10/100Mbps à chaque client rattaché tout en évitant des problèmes de saturation de la bande. Cet interrupteur possède également une fonction auto MDI / MDI-X. Chaque port peut être utilisé pour être connecté à un autre interrupteur ou plate-forme sans câble de croisement RJ-45.
Le mode d’interrupteur enregistrement et transmission permet un faible temps d’attente et élimine toutes les erreurs de réseau, y compris les groupes d’erreurs runt et CRC. Pour travailler en mode bidirectionnel simultané, la transmission et la réception des éléments peut être effectuée de façon simultanée sans provoquer de collisions ainsi que de doubler la largeur de bande du réseau.
L’interrupteur est très facile à utiliser, sans aucun logiciel à configurer ; il est aussi pleinement compatible avec toutes sortes de protocoles de réseau. De plus, les DELs performants situés sur la face avant fournissent des informations sur l’état du port individuel et sur la globalité du système.
Avant d’installer l’interrupteur, veuillez vérifier le contenu du paquet
Un interrupteur NWay Un câble de courant Guide d’utilisation Vis et système de montage sur socle
(Fixation au format rack 19" optionnellement pour modèle pas 19")
6
Définition des LED
Veuillez consulter le tableau ci-dessous pour obtenir les caractéristiques DEL
Modèle 10.5 pouces
Modèle 19 pouces
DEL Etat Fonctionnement
tension Connexion/ action
Panneau ARRIÈRE
Le panneau arrière est indiqué ci-dessus :
Vert continu Sous tension Sous Eteint Hors tension Vert continu Le port est connecté Vert clignotant Le port est en cours de transmission /
Hors tension Pas de connexion
réception de données.
7
Connexion des stations
Reliez chaque station à l’interrupteur à l’aide du câble double torsadé. Branchez un connecteur RJ-45 à un port RJ-45 de l’interrupteur, et branchez l’autre connecteur RJ-45 dans l’adaptateur de réseau de station. Allumez l’interrupteur, et le système est prêt. Pour choisir le câble, consulter le tableau suivant.
Connexion de switches
Pour réaliser une interconnexion d’interrupteur, vous pouvez utiliser n’importe quel port pour brancher un autre interrupteur au moyen d’un câble direct ou de croisement. Comme tous les ports supportent une fonction auto MDI / MDI-X, il est possible d’utiliser un câble direct pour réaliser une connexion d’interrupteur à interrupteur.
Pour choisir le câble, consulter le tableau suivant.
Vitesse du réseau Type de câble
10Mbps Cat. 3, 4, 5 UTP/STP 100 mètres 100Mbps Cat. 5 UTP/STP 100 mètres
Système de montage
Système de montage sur socle L’interrupteur peut fonctionner de façon autonome, ou peut être monté dans un système standard 19 pouces. Le montage sur socle permet un rangement méthodique de votre installation si vous posséder plusieurs autres appareils périphériques. L’interrupteur est fourni avec deux socles de montage en option et des vis. Ces éléments vous permettent de monter l’unité sur socle.
Longueur maximum
8
Spécifications
Standard IEEE 802.3 10BASE-T
Interface 16 ports *10/100Mbps RJ-45 Fast Ethernet
Liaison montante Auto MDI/MDI-X Auto croisement
IEEE 802.3u 100BASE-TX IEEE 802.3x fonctionnement en bidirectionnel
simultané et contrôle de flux
Vitesse du réseau 10/100Mbps & mode bidirectionnel simultané et
Tableau adr. MAC Entrées MAC 8K
Mémoire 160K bytes Courant électrique Alimentation en courant électrique
EMI CE et FCC catégorie A
non simultané auto détection
3.3V 4A (100-240V/ 50-60Hz)
9
Loading...
+ 24 hidden pages