Lodar 9210RX User Manual

w9210RX.09
8-10 Function Receiver
RECEIVER PART NUMBER
9210RX 8-10 Function Receiver, with Master
IP 92210TX Slim 92308TX X 92508TX
RECEIVER SPECIFICATION
ELECTRICAL
Voltage Nominal 12/24V DC Voltage Min/Max 8 to 36V DC Switch Type MOSFET (Positive Switching)
RF
Modulation 2-GFSK. Gaussian Frequency Shift Keying Frequency 433.050 MHz to 434.790 MHz
902.025 MHz– 927.975 MHz Channels 32 Channel Selection Fixed Channel hopping Technology Fixed Receiver Temperature Range -40o C to + 80o C (-40o F to + 176o F). Range 60m (200ft)
CURRENT CAPACITY
FET Rating 10A System Rating 10A Quiescent Current 31mA 12V/ 17mA 24V on Standby (Not SET) Overload Protection 10A (Auto Shutdown)
AERIAL
Internal Antenna Yes Supplied and fitted External Antenna Optional AC9860/ AC9861/ AC9862/ AC9863 & AC9869 – order separately
OUTPUTS
Master Yes Parallel or Continuous Function 10 Supply to Receiver is switched
CONFIGURATION
RS232 Programming Yes For programming interlocks, push/push latch, parallel master inhibit, timeout, channel timeout delay, to users’ requirements master on delay, radio button de-latching and output allocation.
PERFORMANCE
Simultaneous Outputs Yes Programable (Modify through configuration) Instant TX response Yes Programable (Modify through configuration)
DIAGNOSTICS
LED’s Yes Confirm 5 Volts, SET, Fault and all Outputs.
CONTENTS
1 x Receiver 1 x Instructions
w9210RX.09
PROTECTION
Back EMF Yes Diode protection on all outputs Registration codes Yes Over 16 million STOP Connection Yes Internal Emergency Stop Connection
WIRING
Wiring Loom No Upon Request Cable Gland Yes Supplied (Not fitted) Connections Screw terminal into plug and socket on PCB, for easy “swap out”
ENCLOSURE
Weight 0.5 lbs (335gms) Lid Clear PC/FR V0 and UV stabilised Base Black PC V0 and UV stabilised Breather Gortex fitted in base Mounting 4 external lugs Fixings 5mm (3/16”) not supplied IP Rating IP55
92 Series
9210RX
BUILD SPECIFICATION TABLE FOR MODELS IN THIS RANGE
Ident
Legend
Connection
+ -
Positive, Negative,
S
M, F1, F2, F3
Master F1, F2 and F3
S
F4, F5, F6, F7
F4, F5, F6 & F7
S
F8, F9 & F10
F8, F9 & F10
S
S+, S-
Safety Solenoid S+ and S-
S
STOP, 0V
STOP connections
S
X4
ANT Internal Antenna
S
X5
SMA (external antenna)
S
LK1
LK1
Master - Parallel
C
LK2
LK2
Master - Continuous
C
RS232
RS232
S
S = Standard. C = Customer configured (see “Factory Settings”).
+ Positive 8-36V supply
- Negative 0 Volts F1 to F10 Outputs to F1 through F10 M Master Output STOP - STOP, when grounded shuts down the Receiver S+ S- Master Secondary for Safety solenoid connections etc. ANT Blade connector for internal antenna SMA Aerial connection for optional external antenna (internal antenna must be removed) LK1 Master Selection by Jumper (Parallel) LK2 Master Selection by Jumper (Continuous) Factory Settings 418/915MHz configured Parallel, 433.92MHz configured Continuous RS232 RS232 for Wired Remote and interface to access special programmes
Loading...