Liquid Controls E-7 User Manual

Specification Sheet
E-7 Electronic Two-Stage Preset Valve
The Liquid Controls E-7 Electronic, Two-Stage, Preset Valve is designed for refined fuel applications including gasoline, gasohol, diesel fuel, and fuel oil. The valve is available as part of a complete, new metering system with electronic registration or as a retrofit when upgrading from mechanical to electronic registration. The E-7 valve may be used with M5, M7, and M10 Class 1 meters.
Indexible design for 90° rotational adjustment of valve outlet.
Interchangeability (same mounting dimensions) with the V-7 and K-7 mechanical valves.
Two-stage operation for preset deliveries.
Fast response for quick valve shut-off.
The E-7 Series electronically-actuated piston valve is mounted on the meter outlet and provides a compact installation. The valve is operated by two solenoids. These solenoids control two-stage closure with a dwell period to eliminate hydraulic shock.
The valve solenoids are wired to a Liquid Controls LectroCount Electronic Register and are controlled by the register software. During a delivery, the valve opens to allow full flow through the meter. For preset deliveries, the full flow solenoid de-energizes at the point where dwell flow is activated. This reduces the flow rate through the meter. Once the delivery preset volume is reached, the valve fully closes without hydraulic shock to the system.
Technical Specifications
Environmental Rating
NEMA 4X
Safety
Designed to meet Class I, Division 2 requirements
Materials of Construction Valve Body: Aluminum Elastomers: Viton O-Rings, Teflon Seal, Acetal
Wear Rings
Pilot Control System Solenoids, Tubing and Fittings: Brass
solenoids and fittings with flared copper tubing
Temperature Rating
-40° to 160°F (-40° to 71°C)
Pressure Rating
Maximum non-shock working pressure
• 150 PSI (10.3 BAR) Maximum differential pressure
• 100 PSI (6.9 BAR)
Maximum Nominal Flow
150 GPM (568 L/min) for 30 SSU products
Viscosity Range
30 to 100 SSU
Products Class 1: refined fuels (gasoline, gasohol,
diesel fuel, and fuel oil)
Solenoids Voltage: +10.2 to 13.6 VDC (Optional Voltage: +20.4 to 27.2 VDC) Current: S1: 1 Amp, S2: 2 Amps maximum
Specifications
www.lcmeter.com
Dimensional Drawing
NOTE: Dimensions shown are not for construction use.
Consult factory when certified Engineering Drawings are required.
A Unit of IDEX Corporation 105 Albrecht Drive Lake Bluff, IL 60044-2242
1.800.458.5262 847.295.1050 Fax: 847.295.1057 www.lcmeter.com
© 2004 Liquid Controls
Pub. No. 500330
(12/04)
Loading...