Lippert Components Flow Max 719323, Flow Max 719324, Flow Max 719325, Flow Max 719335, Flow Max 719326 Installation And Owner's Manual

...
TM
Flow Max Galley Faucets
Installation and Owners Manual
(For Aftermarket Applications)
Flow MaxTM Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
Introduction ............................................ 2
Quick Facts ............................................ 2
Safety Information ..................................... 2
Parts List ................................................ 2
Resources Required ................................... 3
Prior to Installation ..................................... 3
Installation .............................................. 3
Fixed Faucet ........................................... 3
Pull Down Faucet ...................................... 4
Operation ............................................... 5
Fixed Faucet ........................................... 5
Pull Down Faucet ...................................... 6
Troubleshooting Chart ................................. 7
Maintenance ............................................ 7
Notes .................................................... 8
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
1
CCD-0001241
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
Introduction Parts List
Add a splash of modern to your kitchen or bath with a Stainless Steel Faucet by Lippert Components. Available in a variety of spout constructions like coiled spring and high-arched, we’re challenging how the world feels about faucets. Constructed with quality stainless steel, these sleek faucets are designed for maximum lifespan and durability.
Quick Facts
• 304 Grade stainless steel construction
• Pull-down faucet with toggle
• Toggle for stream or spray options (Pull down only)
• Easy DIY installation
• Pairs well with stainless sink sets by Lippert Components.
*
Items sold separately
*
719323 - Spring Faucet
Pull Down Installation
TM
719324 - Curved Gooseneck
Fixed Installation
Safety Information
THE “WARNING” SYMBOL ABOVE IS A SIGN THAT AN INSTALLATION PROCEDURE HAS A SAFETY RISK INVOLVED AND MAY CAUSE DEATH OR SERIOUS PERSONAL INJURY IF NOT PERFORMED SAFELY AND WITHIN THE PARAMETERS SET FORTH IN THIS MANUAL. ALWAYS WEAR EYE PROTECTION WHEN PERFORMING THIS INSTALLATION PROCEDURE. OTHER SAFETY EQUIPMENT TO CONSIDER WOULD BE HEARING PROTECTION, GLOVES, AND POSSIBLY A FULL FACE SHIELD, DEPENDING ON THE NATURE OF THE INSTALLATION PROCEDURE.
MOVING PARTS CAN PINCH, CRUSH OR CUT. KEEP CLEAR AND USE CAUTION.
719325 - Square Gooseneck
Fixed Installation
719333 - Bullet Pull Down
Pull Down Installation
719326 - Pull Down Sprayer
Pull Down Installation
719335 - Alphorn Pull Down
Pull Down Installation
Part # Description Size
719323 Spring Faucet 16.69” H x 8.26” D
719324 Curved Gooseneck Faucet 14.18” H x 8.15” D
719325 Square Gooseneck Faucet 13.67” H x 7.87” D
719326 Pull Down Sprayer Faucet 17.15” H x 9.12” D
719333 Bullet Pull Down Faucet 17.15” H x 9.12” D
719335 Alphorn Pull Down Faucet 17.15” H x 9.12” D
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
2
CCD-0001241
Resources Required
• Phillips screw driver
• Adjustable wrenches
• Bucket
• Flashlight
• Safety glasses
TM
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
3. Place the faucet supply lines through the mounting
hole on the deck, making sure the black rubber washer
and faucet base are seated rmly on the deck of the sink
(Fig.2A).
4. Position the faucet base so the handle is to the right side of the faucet base (Fig.2B).
Prior to Installation
1. Shut off the hot and cold water outlet supply valves for
the existing faucet, typically located below the sink.
2. Relieve any pressure from the existing faucet by turning the existing faucet on and off.
3. Place a bucket under the sink, under the supply lines’ supply valves to catch any excess water.
4. Using an adjustable wrench, disconnect the supply lines from the outlet water supply valves. Place the supply lines into the bucket to drain any excess water.
5. Under the sink, disconnect the mounting hardware for the existing faucet and remove the faucet from the deck.
6. Make sure the deck around the mounting hole area is clean, dry and free from any debris.
Installation
Fixed Faucet
1. Unscrew the metal collar with the two screws from the faucet base and set aside (Fig.1A).
2. Remove the metal washer (Fig.1B) from the base and
set aside.
NOTE: The handle can be positioned to the left of the faucet base but is typically placed to the right. Placing the handle in the middle may cause severe burns depending on where the faucet neck is located when turning on the water.
B
A
Fig.2
5. Under the sink, slide the metal washer (Fig. 1B) over
the supply lines onto the base of the faucet. Make sure
the metal washer is ush against the underside of the sink
deck and covering the mounting hole (Fig.3A).
NOTE: Leave black rubber washer (Fig.1C) on faucet.
C
B
A
Fig.1
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
3
Fig.3
faucet base
sink deck
A
CCD-0001241
TM
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
6. Make sure the two screws on the coupler are evenly inserted and are ushed with the top of the coupler (Fig.4A).
A
Fig.4
7. Screw the coupler onto the faucet base all the way up to the metal washer (Fig.5A).
NOTE: Make sure the handle of the faucet is placed in the
desired position.
8. Using a Phillips screwdriver, tighten the two screws (Fig.5B) on the coupler to hold the coupler into place.
Pull Down Faucet
1. Unscrew the black plastic coupler from the faucet base
and slide off from the faucet assembly.
NOTE: Wiggle the plastic coupler off the supply lines one line at a time.
2. Slide the clear plastic washer off the faucet assembly.
3. Place the faucet supply lines through the mounting
hole on the deck, making sure the black rubber washer
and faucet base are seated rmly on the deck of the sink
(Fig.6A).
A
Fig.6
4. Under the sink, slide the clear plastic washer over the
A
B
Fig.5
NOTE: The red marked supply line is for hot water and the
blue marked supply line is for the cold water.
9. Thread the nut on the hot water supply line onto the hot water outlet supply valve and tighten with an adjustable wrench. Do not over tighten.
10. Thread the nut on the cold water supply line onto the cold water outlet supply valve and tighten with an adjustable wrench. Do not over tighten.
11. Turn the hot and cold water outlet supply valves back on and check for any leaks.
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
supply lines up to the underside of the sink deck and covering the mounting hole (Fig.7A).
A
4
Fig.7
CCD-0001241
5. Slide the black plastic coupler back onto the supply lines, inserting one supply line at a time.
NOTE: Make sure the inside threads of the black plastic coupler are at the top.
6. Screw the black plastic coupler all the way up the faucet base until it will no longer turn (Fig.8A).
A
TM
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
Operation
Fixed Faucet
1. Pull the lever away from the faucet to turn it on (Fig.9A).
A
Fig.8
NOTE: The red marked supply line is for hot water and the
blue marked supply line is for the cold water.
7. Thread the nut on the hot water supply line onto the hot water outlet supply valve and tighten with an adjustable wrench. Do not over tighten.
8. Thread the nut on the cold water supply line onto the cold water outlet supply valve and tighten with an adjustable wrench. Do not over tighten.
9. Turn the hot and cold water outlet supply valves back on and check for any leaks.
Fig.9
2. Move the lever towards you for hot water (Fig. 10) and away from you for cold water (Fig. 11).
NOTE: Located on the front of the lever is a “H” for hot
water and a “C” for cold water. Move the lever in the direction of the desired temperature.
right profile
view
right profile
view
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
Fig.10 Fig.11
5
CCD-0001241
TM
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
3. Push the lever in towards the faucet to shut the water off (Fig.12A).
A
Fig.12
Pull Down Faucet
1. Pull the lever away from the faucet to turn it on (Fig.13A).
2. Move the lever towards you for hot water (Fig.14) and away from you for cold water (Fig.15).
NOTE: Located on the front of the lever is a “H” for hot
water and a “C” for cold water. Move the lever in the direction of the desired temperature.
right profile
view
Fig.14 Fig.15
3. To use the spray wand pull down and out on the faucet
head.
4. Press and release the button in on the lower portion of the faucet head (Fig.16A) for spray mode. Press and release the button again for stream mode.
right profile
view
Fig.13
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
A
A
Fig.16
5. Replace the faucet head by gently guiding the hose back
into the faucet neck and insert into clip, if applicable.
6
CCD-0001241
6. To shut the water off push the lever in towards the faucet (Fig.17).
A
Fig.17
TM
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
Maintenance
Clean the faucet periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as
these will dull the nish and void the warranty.
Troubleshooting Chart
Vibration caused by driving or transporting can loosen plumbing and hardware. Check for loose system components. Many symptoms can be resolved by tightening hardware. Use care not to over-tighten. Refer to the chart for troubleshooting tips.
What is happening? Why? What should be done?
1. Unscrew the spray wand assembly.
2. Remove the O-ring and screen.
3. Clean screen by rinsing it for a few
Irregular Flow Blockage at the screen
There is a leak from the aerator when the faucet is on.
The aerator has irregular or reduced water flow.
The aerator does not fit correctly on the faucet.
The aerator is dirty. Remove aerator and clear debris.
seconds to remove any debris.
4. Reinsert O-ring and screen.
5. Screw the spray wand to the pull down hose and tighten.
1. Reinstall aerator.
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
7
CCD-0001241
Notes
Notes
TM
Flow Max Galley Faucets
Installation and Owner’s Manual
(For Aftermarket Applications)
lci1.com 574 - 5 3 7- 89 0 0 Rev : 0 4 .10.18
Manual information may be distributed as a complete document only, unless Lippert Components provides explicit consent to distribute individual parts.
All manual information is subject to change without notice. Revised editions will be available for free download at lci1.c om. Manual information is considered factual until made obsolete by a revised version.
Please recycle all obsolete materials and contact Lippert Components with concerns or questions.
8
CCD-0001241
Loading...