Linear GRD, GRD-2 User Manual

GRD
SWITCHES IN TRANSMITTER
THIS SWITCH HAS 2, 3 & 6 ON
REMOVE BATTERY ACCESS DOOR
CODING SWITCH
SET CODE
SWITCH KEYS
THIS SWITCH HAS 2, 3 & 6 ON
CHANNEL ONE
SWITCH KEYS
DO NOT USE: ALL ON; ALL OFF; ALT ON/OFF, OR OFF/ON
MOUNT RECEIVER INSIDE GATE HOUSING
SECURE CASE CLOSED WITH TWO SCREWS AT BOTTOM OF CASE
GATE OPERATOR
24 V RADIO POWER
RELAY
COMMON
1
2
3
MANUAL ACCESS REQUEST
OBSTACLE
COMMON
1
2
OBSTACLE INPUT
CHANNEL
ONE
GRAY
YELLOW
CHANNEL
TWO
GATE OPERATOR
24 V RADIO POWER
RELAY
COMMON
1
2
3
MANUAL ACCESS REQUEST
INPUT VOLTAGE REQUIREMENT 12 TO 30 VOLTS AC
10.5 TO 30 VOLTS DC
OBSTACLE
BLACK
RED
CONNECT COAXIAL CABLE TO "F" CONNECTOR
SLIDE WEATHER RESISTANT CAP OVER CONNECTION
INSERT BULKHEAD CONNECTOR THROUGH OPERATOR HOUSING
SECURE CONNECTOR TO HOUSING USING WASHER AND NUT
CONNECT CABLE TO BULKHEAD CONNECTOR
RECEIVER
LOCAL
ANTENNA BULKHEAD
CONNECTOR
3-FOOT
CABLE
CASE SCREWS
MOUNTING
HARDWARE
WASHER
NUT
SQUEEZE BOTH SIDES A T TABS AND TILT UPWARD
SET CHANNEL TWO CODE SWITCH KEYS
THIS SWITCH HAS 2, 4 & 6 ON
CHANNEL TWO SWITCH KEYS
DO NOT USE: ALL ON; ALL OFF; ALT ON/OFF, OR OFF/ON
GRD-2
Installation Instructions
(800) 421-1587 www.linearcorp.com
DESCRIPTION
The GRD is a digital receiver designed for use with automatic gate operators or systems where a remote antenna is needed. The GRD-2 will operate two gates, one gate and an obstacle sensor, or channel one can open the gate and channel two can close the gate.
All of the Delta-3 transmitters, including the two and four-channel transmitters, are compatible with the GRD. The Delta-3 radio format provides 256 different digital codes. The codes are set using the 8-position coding switches in the units. In order to avoid the possibility of duplicating codes in adjacent systems, factory set codes should not be used.
The receivers can operate from 12-30 volts AC or 10.5-30 volts DC and are normally powered from the gate operator. The relay contact(s) are rated at 5 amps @ 32 volts AC/DC NEC Class 2 circuit.
The GRD has a “F” connector for attaching an antenna. The receiver is supplied with a 9-inch local antenna, a three foot 75 ohm coaxial cable, and a bulkhead connector for mounting the antenna outside the gate operator enclosure.
STEP 1 Open receiver case. To open case,
squeeze sides of case and rotate upward.
STEP 2A GRD & GRD-2 Channel 1 code
setting. To set a code, select any valid combination of ON and OFF positions for the switch keys numbered 1- 8. Use a paper clip to set the eight keys.
STEP 5 Connect receiver to power.
Connect the red power input wire to the 24VDC radio power and the black wire to the common terminal on the gate operator. Alternately connect wires to a 12-24 VAC transformer.
STEP 2B GRD-2 Channel 2 code setting.
Select any valid combination of ON and OFF positions for each of the switch keys numbered 1 - 8. Use a different code combination than that
used for channel one switch.
STEP 6 Mounting the receiver. Use the
screws provided to mount the receiver within the operator housing. This provides protection from the elements. Secure case with case screws.
STEP 3 Transmitter code setting. Locate
the coding switch on the transmitter and set the eight keys identical to those on the desired channel of the receiver. Be sure they match exactly. If using a two or four-channel transmitter, refer to the coding instructions included with the transmitter for proper system coding.
STEP 7 Connect antenna. Connect the
coaxial cable to the “F” connector on the receiver. Drill a 3/8" hole on the top of the operator housing for the bulkhead connector. Insert the connector and secure it with the nut and lock washer. Connect the cable and antenna to the bulkhead connector.
STEP 4 Connect receiver relay output.
Connect the appropriate channel wires (Ch. 1 ­two gray wires), (Ch. 2 - two yellow wires) to the appropriate activation terminals on the gate operator.
This Linear product is warranted against defects in mater ial and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale custom ers who buy direct from Linear or through Linear’s normal distribution chann els. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear
Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or pr ofit, or cost of removal, installation, or reins tallation. All
implied warranties, including implied warranties for merchantability and implied warranties for fitnes s, are valid only until War ranty Expiration Da te as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express
or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Co ntact Linear Technical S ervices at 1-800-421- 1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed.
1 For U.S. installations only: The radios are required to comply with FCC Rules and
Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
1 A receiver cannot respond to more than one transmitted signal at a time and may be
blocked by radio signals that occur on or near their operating frequ encies, regardless of code settings.
1 Changes or modifications to the device may void FCC compliance. 1 Infrequently used radio links should be tested regu larly to protect against undetected
interference or fault.
1 A general knowledge of radio and its vagaries should be gained prior to acting as a
wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2003 Linear Corporation 220812 A
LINEAR LIMITED WARRANTY
Loading...