DESCRIPTION

The GRD has a “F” connector for attaching an antenna. The

STEP 1 Open receiver case. To open case,

 

 

The GRD is a digital receiver designed for use with automatic

receiver is supplied with a 9-inch local antenna, a three foot

squeeze sides of case and rotate upward.

GRD-2

 

gate operators or systems where a remote antenna is

75 ohm coaxial cable, and a bulkhead

connector for

 

 

 

 

mounting the antenna outside the gate operator enclosure.

 

 

 

 

needed. The GRD-2 will operate two gates, one gate and

 

 

 

 

 

 

 

an obstacle sensor, or channel one can open the gate and

 

 

 

 

 

 

 

 

 

 

 

channel two can close the gate.

RECEIVER

 

 

 

 

 

 

 

 

 

 

All of the Delta-3 transmitters, including the two and

 

 

 

 

 

 

 

 

 

 

 

 

 

3-FOOT

 

 

 

DELTA-3

 

 

four-channel transmitters, are compatible with the GRD.

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Delta-3 radio format provides 256 different digital codes.

 

 

 

 

 

 

 

GATE

 

 

 

The codes are set using the 8-position coding switches in

 

 

 

CASE SCREWS

 

 

 

RECEIVER

 

the units. In order to avoid the possibility of duplicating codes

 

 

 

 

 

 

 

 

in adjacent systems, factory set codes should not be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Instructions

The receivers can operate from 12-30 volts AC or 10.5-30

 

 

 

 

 

 

 

volts DC and are normally powered from the gate operator.

 

 

 

MOUNTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The relay contact(s) are rated at 5 amps @ 32 volts AC/DC

 

 

 

HARDWARE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEC Class 2 circuit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCAL

 

NUT

 

 

 

 

 

 

 

 

 

 

ANTENNA

BULKHEAD

WASHER

SQUEEZE BOTH SIDES AT TABS

 

 

 

 

 

 

 

 

 

CONNECTOR

AND TILT UPWARD

 

 

(800) 421-1587 www.linearcorp.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 2A

GRD & GRD-2 Channel 1 code

STEP 2B

GRD-2 Channel 2 code setting.

STEP 3

Transmitter code setting. Locate

STEP 4 Connect receiver relay output.

setting.

To

set a code,

select any valid

Select any valid combination of ON and OFF

the coding switch on the transmitter and set the

Connect the appropriate channel wires (Ch. 1 -

combination of ON and OFF positions for the

positions for each of the switch keys numbered

eight keys identical to those on the desired

two gray wires), (Ch. 2 - two yellow wires) to the

switch keys numbered 1- 8. Use a paper clip to

1 - 8. Use a different code combination than that

channel of the receiver. Be sure they match

appropriate activation terminals on the gate

set the eight keys.

 

used for channel one switch.

exactly. I f

u s i n g a t w o

o r f o u r - c h a n n e l

operator.

 

 

SET CODE

 

 

 

transmitter, refer to the coding instructions

 

GATE OPERATOR

 

 

 

included with the transmitter for proper system

 

SWITCH KEYS

 

SET CHANNEL TWO

coding.

 

 

 

 

 

MANUAL ACCESS

 

 

 

 

 

 

REQUEST

 

 

 

 

CODE SWITCH KEYS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANNEL ONE

 

 

 

 

 

 

 

 

 

 

SWITCH KEYS

 

CHANNEL TWO

REMOVE BATTERY

 

 

 

 

COMMON

 

 

 

 

ACCESS DOOR

 

 

 

 

1

 

 

 

 

SWITCH KEYS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCHES IN

CHANNEL

2

RELAY

 

 

 

 

 

 

 

 

TRANSMITTER

ONE

 

 

 

 

 

 

 

 

 

 

GRAY

 

 

 

 

 

 

 

 

 

 

 

 

3 24 V RADIO POWER

 

 

 

 

 

 

 

 

 

 

 

THIS SWITCH

 

THIS SWITCH

 

 

 

 

 

 

 

HAS 2, 3 & 6 ON

 

 

 

 

 

 

OBSTACLE INPUT

 

 

 

 

HAS 2, 4 & 6 ON

 

CODING

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT USE:

 

 

 

 

SWITCH

 

 

YELLOW

1

COMMON

 

DO NOT USE:

 

 

 

THIS SWITCH

ALL ON; ALL OFF;

 

 

 

 

CHANNEL

 

 

 

ALL ON; ALL OFF;

 

 

 

HAS 2, 3 & 6 ON

TWO

2

OBSTACLE

ALT ON/OFF, OR OFF/ON

 

 

 

 

 

ALT ON/OFF, OR OFF/ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 5

C o n n e c t re c e i ver to power .

STEP 6

Mounting the receiver. U s e the

STEP 7

Connect antenna. C o n n e c t t h e

LINEAR LIMITED WARRANTY

This Linear product is warranted against defects in material and workmanship for twelve

Connect the red power input wire to the 24VDC

screws provided to mount the receiver within the

coaxial cable to the “F” connector on the receiver.

(12) months. The Warranty Expiration Date is labeled on the product. This warranty

radio power and the black wire to the common

operator housing. This provides protection from

Drill a 3/8" hole on the top of the operator housing

extends only to wholesale customers who buy direct from Linear or through Linear’s

normal distribution channels. Linear does not warrant this product to consumers.

terminal on the gate operator. Alternately connect

the elements. Secure case with case screws.

for the bulkhead connector. Insert the connector

Consumers should inquire from their selling dealer as to the nature of the dealer’s

wires to a 12-24 VAC transformer.

 

 

and secure it with the nut and lock washer.

warranty, if any. There are no obligations or liabilities on the part of Linear

 

 

Corporation for consequential damages arising out of or in connection with use

 

 

 

 

 

 

Connect the cable and antenna to the bulkhead

or performance of this product or other indirect damages with respect to loss of

 

 

 

 

 

 

connector.

 

 

 

property, revenue, or profit, or cost of removal, installation, or reinstallation. All

 

 

 

 

 

 

 

 

 

implied warranties, including implied warranties for merchantability and implied

 

 

 

 

 

 

 

 

 

 

 

 

GATE OPERATOR

 

 

 

 

 

 

warranties for fitness, are valid only until Warranty Expiration Date as labeled on the

 

 

 

 

 

 

 

 

product. This Linear Corporation Warranty is in lieu of all other warranties express

 

 

 

 

 

 

 

 

 

 

or implied.

 

 

 

 

 

MANUAL

 

MOUNT RECEIVER

 

 

SLIDE WEATHER

All products returned for warranty service require a Return Product Authorization

 

 

 

ACCESS REQUEST

 

 

 

Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA#

 

 

 

 

INSIDE GATE

 

 

 

 

 

 

 

 

 

RESISTANT CAP

and other important details.

 

 

 

 

 

 

 

HOUSING

CONNECT COAXIAL

OVER CONNECTION

IMPORTANT !!!

 

 

 

 

 

OBSTACLE

 

 

CABLE TO "F"

 

 

 

Linear radio controls provide a reliable communications link and fill an important need

 

 

BLACK

 

 

 

CONNECTOR

 

 

 

in portable wireless signaling. However, there are some limitations which must be

 

 

 

 

 

 

 

INSERT BULKHEAD

observed.

 

 

 

 

1

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTOR THROUGH

For U.S. installations only: The radios are required to comply with FCC Rules and

 

 

 

 

 

 

 

 

 

 

2

RELAY

 

 

 

 

OPERATOR HOUSING

Regulations as Part 15 devices. As

such, they have limited transmitter power and

 

 

 

 

 

 

therefore limited range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

A receiver cannot respond to more than one transmitted signal at a time and may be

 

 

24 V RADIO POWER

 

 

 

 

 

 

blocked by radio signals that occur on or near their operating frequencies, regardless of

 

 

3

 

SECURE CASE

 

 

 

 

code settings.

 

 

 

 

 

 

 

 

 

SECURE CONNECTOR

 

 

 

 

 

 

 

CLOSED WITH TWO

 

 

Changes or modifications to the device may void FCC compliance.

 

 

 

 

 

 

 

TO HOUSING USING

Infrequently used radio links should be tested regularly to protect against undetected

 

 

 

 

 

SCREWS AT BOTTOM

 

 

 

 

INPUT VOLTAGE REQUIREMENT

 

 

 

WASHER AND NUT

interference or fault.

 

 

 

 

 

OF CASE

 

 

 

 

A general knowledge of radio and its vagaries should be gained prior to acting as a

 

 

12 TO 30 VOLTS AC

 

 

 

 

CONNECT CABLE TO

wholesale distributor or dealer, and these facts should be communicated to the ultimate

 

 

10.5 TO 30 VOLTS DC

 

 

 

 

users.

 

 

 

 

 

 

 

 

BULKHEAD CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2003 Linear Corporation

220812 A