Linear DXS-72 User Manual

DXS-72
TWIST MOUNTING PLATE TO UNLOCK
REMOVE MOUNTING PLATE
WIRELESS PHOTOELECTRIC SMOKE ALARM
Installation Instructions
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000
Toll Free FAX (800) 468-1340
www.linearcorp.com
DXS-72 FEATURES INSTALL BATTERIES CHOOSE ALARM LOCATION
DXS
FORMAT
By
PRODUCT DESCRIPTION
receiver channel. Receivers must be programmed to the transmitter’s code before system testing and operation.
Refer to the receiver’s instructions for details on programming. The unit is powered by two 9-volt alkaline or lithium batteries. These batteries are supplied with the transmitter and can power the unit for up to two years. Every hour, the DXS-72 will send a status transmission to the receiver. The hourly signal updates the receiver to the transmitter’s condition. By monitoring status transmissions, the receiver can determine if a transmitter has a low battery or has been removed from the system. If the battery voltage drops below a preset level the alarm will sound low battery beeps and a low battery signal will be sent to the receiver with status reports (some receivers can report low battery status, others cannot).
NOTE: After replacing batteries, press transmitter test button to
reset “low battery circuit”.
REMOVE MOUNTING PLATE
TRANSMITTER BOARD
BATTERY HOLDING CUPS
INSTALL MOUNTING PL ATE PROGRAM RECEIVER MOUNT ALARM ON PL ATE
TRANSMIT LED
TRANSMITTER TEST BUTTON
SCREW ANCHORS FOR WALLBOARD
PRESS TRANSMITTER TEST BUTTON AFTER INSTALLING BATTERIES TO RESET LOW BATTERY CIRCUIT
CONNECT AND INSTALL TWO 9-VOLT BATTERIES
REFER TO RECEIVER'S INSTRUCTIONS TO PREPARE RECEIVER TO ACCEPT THE TRANSMITTER'S CODE
9-VOLT BATTERY TYPES:
EVEREADY 216, 522, OR 1222 DURACELL MN1604 GOLD PEAK 1604P, 1604S ULTRALIFE LITHIUM U9VL
PRESS TRANSMITTER TEST BUTTON TO SEND SIGNAL
MATCH UP ALIGNMENT TABS
OR
PLASTIC SINGLE-GANG ELECTRICAL BOX
TWIST SMOKE ALARM CLOCKWISE TO LOCK TO MOUNTING PLATE
TEST SYSTEM STANDARD FOR ALARM LOCATION
PRESS AND HOLD ALARM TEST BUTTON FOR ONE MINUTE
20 SECONDS AFTER SOUNDER STARTS TRANSMITTER WILL SEND SIGNAL
VERIFY THAT RECEIVER ACTIVATES
The purpose of an early warning smoke alarm is to detect the presence of fi re in its early stages, and sound an alarm giving the occupants more time to exit the premise before the smoke reaches a dangerous concentration level. Fires start even with the best of housekeeping and fi re prevention procedures. Fire is an unexpected event. Early warning detection alerts occupants in time to act. KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore, safeguards should be taken to avoid such potentially dangerous situations as: smoking in bed, leaving children home alone, cleaning with fl ammable liquids such as gasoline. The best fi re protection is minimizing fi re hazards through proper storage of materials and general good housekeeping techniques. A cluttered basement, attic, or other storage area is an open invitation to fi re. Careless use of combustible materials and electrical appliances, or overloading of electrical outlets are other prime causes in starting fi res. It is most important that explosive and/or fast burning materials be eliminated from the home, if at all possible. Even after proper precautions have been taken, fi res can star t.
Be prepared.
The DXS-72 should be installed in accordance with National Fire Protection Association (NFPA) Standard 72, which reads as follows: 2-1.1.1 Smoke alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfi nished attics. In new construction, a smoke alarm shall be installed in each sleeping room. 2-1.1.2 For family living units with one or more split levels (i.e., adjacent levels with less than one full story separation between levels), a smoke alarm required by 2-1.1.1 shall suffi ce for an adjacent lower level, including basements. (Exception: Where there is an intervening door between one level and the adjacent lower level, a smoke alarm shall be installed on the lower level.)
Ceiling mounted smoke alarms should be located in the
center of the room or hall, or not less than 4 inches from any wall. When the alarm is mounted on a wall, the top of the alarm should be 4 to 12 inches from the ceiling.
Do not install smoke alarms where normal ambient
temperatures are above 100°F (37.8°C), or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers, or other locations where normal air circulation will keep smoke from entering the detector.
FIRE PREVENTION AND ESCAPE
IN CASE OF FIRE. Leave immediately. Don’t stop to pack or search for valuables. In heavy smoke, hold your breath and stay low - crawl if necessary. The clearest air is usually at the fl oor. If you have to go through a closed door, carefully feel the door and door knob to see if undue heat is present. If they seem relatively cool, brace your foot against the bottom of the door with your hip against the door and one hand against the top edge. Open it slightly. If a rush of hot air is felt, slam the door quickly and latch it. Unvented fi re tends to build up considerable pressure. Be sure all the household realizes and understands this danger. Use your neighbor’s phone or a street fi re alarm box. The job
of extinguishing the fi re should be left to the professionals. Too many unforeseen things can occur when inexperienced people try to extinguish a fi re.
A-2.5.2.1 Smoke Detection - Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required smoke alarms. The installation of smoke alarms in kitchens, attics (fi nished or unfi nished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation. Smoke alarms are not to be used with detector guards unless the combination has been evaluated and found suitable for the purpose.
BE PREPARED. Perform fi re drills regularly. Use them to assure recognition of an alarm signal. For your protection, simulate different circumstances (smoke in hall, in living room, etc.). Then have everyone react to the situation. Draw a fl oor plan and show two exits from each room. Frequently a knotted rope or ladder from a window will serve this purpose. It is important that children be instructed carefully, because they tend to hide in times of crisis. It is imperative that one meeting place outside the home be established. You should insist that everyone meet there during an alarm. This will eliminate the tragedy of someone re-entering the house for a missing member who is actually safe. If you have children and/or invalids residing in your household, you can help your fi re department. Most fi re departments have window decals available for use in children’s or invalid’s bedrooms. Properly used, these decals will quickly identify sleeping quarters of these individuals and show the fi re department where to look fi rst for members of your household.
Additional information on Household Fire Warning
is available at nominal cost from: The National Fire Protection Association, Batterymarch Park, Quincy, MA
02269. Request Standard No. NFPA 72.
EX AMPLE AL ARM LOCATIONS LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of
Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or
implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules
and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time
and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifi cations to the device may void FCC compliance.Infrequently used radio links should be tested regularly to protect against
undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting
as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2006 Linear LLC 212836 G
IMPORTANT!!!
DINING
KITCHEN BEDROOM BEDROOM
SMOKE ALARM
LIVING ROOM
A smoke alarm should be located between the sleeping area and the rest of the family living unit.
DINING KITCHEN BEDROOM
TV
ROOM
BEDROOM
SMOKE
ALARMS
In family living units with more than one sleeping area, a smoke alarm should be provided to protect each.
LIVING ROOM
BEDROOM
BEDROOM
LIVING ROOM
BASEMENT
HALL
BED
ROOM
HALL
DINING
ROOM
BASEMENT
BED
ROOM
BED
ROOM
RECREATION ROOM
Indicates required smoke alarm Indicates optional smoke alarm if door is not provided between Living and Recreation Rooms
BED
ROOM
LIVING ROOM
A smoke alarm should be locatedoneachstory.
Loading...