TRI-GARD 555LS/557LS SIGNATURE SERIES™
audio glassbreak detectors employ state-of-the-art Advanced
Signature Analysis
™
algorithms to sample four bands of audio
instead of one or two like most other detectors. Digital Signal
Processing (DSP) is used to continuously sample and analyze
the sound. Within milliseconds after an audio “event” begins,
the microprocessor starts crunching data. Approximately 1200
comparisons and decisions are made before an event is rejected or confirmed about 0.3 seconds later. Eight glassbreak signature models and four false alarm models, stored in memory ,
are referenced during the confirmation process. The result of
this high-tech performance is more accurate glassbreak detection and improved false alarm rejection in tough environments.
TRI-GARD 555LS/557LS FEA TURES
• Specified for plate,wired, tempered & laminated glass
• Microprocessor-based for better discrimination
• Advanced SignatureAnalysis™
• Signature Supervision
• Omnidirectional sensitivity
• Automatic sensitivity adjustments
TRI-GARD 555LS/557LS APPLICA TIONS
• Glassbreak protection in residential,commercial
and industrial areas
• Protects plate,wired, tempered & laminated glass
• Omni direction detection to protect multiple windows
•Areas with closed drapes or blinds will reduce range.
T est with 517 tester for specific range
•Wall orceiling mount installations
SPECIFICATIONS
SENSING:Audio/air,open space (enclosed area)
RANGE: 25’ for plate, wired, tempered & 20’ for laminated
glass. These ranges are for 1’ X 1’ minimum glass size. For
glass size down to 6” X 10” the range would be reduced by
1/2.
GLASS SIZE: Above stated range is for 1’ X 1’
THICKNESS:Plate- 3¼32" to1¼2"
Tempered–1¼8" to1¼2"
Wired–1¼4"to 1¼2"
Laminated–1¼4" to1¼2"
SENSING FIELD: Omni-directional
S
ENSOR: Electret condenser (F .E.T .pre-amp)
OPERATINGVOLTAGE: 10–16VDC filtered and regulated
P
OWER CONSUMPTION:30 ma @13.6VDC normal, 40 ma @
16 VDC.
O
PERATING TEMPERATURE:14° to120° F (-10° to 49° C)
STORAGE TEMPERATURE:-13° to185° F (-25° to 85° C)
RELA YACTIV ATION TIME: 3 seconds
A
LARM LED: Latch orauto reset
A
LARM RELAY:SPDT (Form-C)- contacts .1Amp @30VAC/24
VDC Relay is energized upon power up (C & NC are closed)
TAMPER CIRCUIT:Normally closed switch-contacts 50
milliamps @ 30VAC/24VDC.
V
OLTAGE
MONITOR
: Low or novoltage causes alarm relay to
open. Lowvoltage <10VDC causes red LED to flash slowly
I
NSTALLATION
: Hardwire 6wires including 2 for tamper
Testing: Follow instructions & test once a year
MOUNTING: Surface– screw andanchors included
C
OLOR
:White or Cabin Brown
SIZE:3" x 3" x 3¼4"
TRI-GARD555LS/557LSSignature Series
™
Audio Glassbreak Detectors
NOTE 1: The use of mini-blinds, shades, drapes* and sun film* can
reduce the range of the detector by 50%. Since room acoustics and window coverings can vary considerably, all detector installations should be
checked with the 517 tester.
* Not for sound deadening drapes
* Tested w/ 3M sun film #SH2CLAR (3M is a trademark of 3M Company)
555LS
557LS