LiftMaster Security+ 3245M, Professional Security+ 3245M, Professional Security+ 3255-2M, Security+ 3255-2M, Professional Security+ 3255M Owner's Manual

®
GARAGE DOOR OPENER
Models 3245M 1/3 HP
3255M 1/2 HP 3255-2M 1/2 HP
The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196
www.liftmaster.com
Owner’s Manual
Please read this manual and the enclosed safety materials carefully!
Fasten the manual near the garage door after installation.
■ The door WILL NOT CLOSE unless the Protector System
aligned.
Periodic checks of the opener are required to ensure safe operation.
The model number label is located on the front panel of your opener.
®
is connected and properly
TABLE OF CONTENTS
Introduction 2-5
Safety symbol and signal word review . . . . . . . . . . . . . . 2
Preparing your garage door. . . . . . . . . . . . . . . . . . . . . . . 3
Tools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Carton inventory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Hardware inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly 6-7
Attach the rail to the motor unit. . . . . . . . . . . . . . . . . . . . 6
Attach the chain to the sprocket . . . . . . . . . . . . . . . . . . . 6
Tighten the chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation 7-22
Installation safety instructions. . . . . . . . . . . . . . . . . . . 7
Determine the header bracket location . . . . . . . . . . . . . . 8
Install the header bracket. . . . . . . . . . . . . . . . . . . . . . . . . 9
Attach the rail to the header bracket . . . . . . . . . . . . . . . 10
Position the opener . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Hang the opener . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Install the door control . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Install the light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Attach the emergency release rope and handle . . . . . . 14
Electrical requirements. . . . . . . . . . . . . . . . . . . . . . . . . . 15
Install the Protector System®. . . . . . . . . . . . . . . . . . .16-18
Fasten the door bracket. . . . . . . . . . . . . . . . . . . . . . .19-20
Connect the door arm to the trolley. . . . . . . . . . . . . .21-22
Adjustment 23-25
Adjust the travel limits . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Adjust the force . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Test the safety reversal system . . . . . . . . . . . . . . . . . . . 25
Test the Protector System
®
. . . . . . . . . . . . . . . . . . . . . . 25
Operation 26-30
Operation safety instructions . . . . . . . . . . . . . . . . . . . . . 26
Using your garage door opener . . . . . . . . . . . . . . . . . . . 26
Using the wall-mounted door control . . . . . . . . . . . . . . 27
To open the door manually . . . . . . . . . . . . . . . . . . . . . . 27
Care of your garage door opener . . . . . . . . . . . . . . . . . 28
Having a problem? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Diagnostic chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Programming 31-32
To add or reprogram a hand-held remote control. . . . . 31
To erase all codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3-Button remotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
To add, reprogram or change
a Keyless Entry PIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Repair Parts 33-34
Rail assembly parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Installation parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Motor unit assembly parts . . . . . . . . . . . . . . . . . . . . . . . 34
Accessories 35
Repair Parts and Service 36
Warranty 36
INTRODUCTION
Safety Symbol and Signal Word Review
This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of
Mechanical
Electrical
serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.
2
Preparing your garage door
Pliers
Wire Cutters
Claw Hammer
Hack Saw
Screwdriver
Adjustable End Wrench
1/2" and 7/16" Sockets and Wrench
Drill
Tape Measure
2
1
Stepladder
Pencil
3/16", 5/16" and 5/32" Drill Bits
Carpenter’s Level (Optional)
Before you begin:
• Disable locks.
• Remove any ropes connected to garage door.
Complete the following test to make sure your garage
door is balanced and is not sticking or binding:
1. Lift the door about halfway as shown. Release the door. If balanced, it should stay in place, supported entirely by its springs.
2. Raise and lower the door to see if there is any binding or sticking.
If your door binds, sticks, or is out of balance, call a trained door systems technician.
To prevent possible SERIOUS INJURY or DEATH:
• ALWAYS call a trained door systems technician if garage door binds, sticks or is out of balance. An unbalanced garage door may NOT reverse when required.
• NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
• Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement.
To prevent damage to garage door and opener:
• ALWAYS disable locks BEFORE installing and operating the opener.
• ONLY operate garage door opener at 120V, 60 Hz to avoid malfunction and damage.
Sectional Door
One-Piece Door
Tools needed
During assembly, installation and adjustment of the opener, instructions will call for hand tools as illustrated below.
3
Planning
Safety Reversing Sensor
Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 19 for details.
— — — — — — — —
Header Wall
Safety Reversing Sensor
Gap between floor and bottom of door must not exceed 1/4" (6 mm).
Extension Spring
Torsion Spring
Access Door
OR
Slack in chain tension is normal when garage door is closed.
Wall­mounted Door Control
Motor Unit
FINISHED CEILING
Support bracket & fastening hardware is required. See page 12.
Vertical Centerline of Garage Door
Access Door
Safety Reversing Sensor
Safety Reversing Sensor
Slack in chain tension is normal when garage door is closed.
Gap between floor and bottom of door must not exceed 1/4" (6 mm).
Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be
SECTIONAL DOOR INSTALLATION
required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.
ONE-PIECE DOOR WITHOUT TRACK
Slack in chain tension is normal when
Header
Safety Reversing Sensor
Wall
Gap between floor and bottom of door must not exceed 1/4" (6 mm).
garage door is closed.
Wall-mounted Door Control
Safety Reversing Sensor
FINISHED CEILING
Support bracket & fastening hardware is required. See page 12.
Access Door
Motor Unit
ONE-PIECE DOOR WITH TRACK
4
Carton Inventory
Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model purchased.
Models 3245M, 3255M (1) Model 3255-2M (2)
LOCK
LIGHT
Multi-Function Door Control Panel
Motor Unit with Light Lens
CEILING MOUNT ONLY
UP
SECURITY Single-Button Remote Control
2 Conductor Bell Wire White & White/Red
®
If anything is missing, carefully check the packing material. Parts may be stuck in the foam. Hardware for installation is also listed below.
Remote Control Visor Clip
One-Piece Rail
Chain
Sprocket Cover
Styrofoam
Header Bracket
Chain Pulley Bracket
Safety Sensor Bracket (2)
INSTALLATION HARDWARE
Hex Bolt 5/16"-18x7/8" (4) Lag Screw 5/16"-9x1-5/8" (2) Lag Screw 5/16"-18x1-7/8" (2) Clevis Pin 5/16"x2-3/4" (1) Clevis Pin 5/16"x1-1/4" (1) Clevis Pin 5/16"x1" (1) Nut 5/16"-18 (4) Lock Washer 5/16" (4) Screw 6ABx1-1/4" (2) Screw 6-32x1" (2) Self-Threading Screw 1/4"-14x5/8" (2)
Trolley
Door Bracket
The Protector System (2) Safety Reversing Sensors (1 Sending Eye and 1 Receiving Eye) with 2-Conductor White & White/Black Bell Wire attached
®
Insulated Staples (30) Ring Fastener (3) Drywall Anchors (2) Rail Grease Carriage Bolt 1/4"-20x1/2" (2) Wing Nut 1/4"-20 (2) Rope Handle
Curved Door Arm Section
Safety Labels
and
Literature
Straight Door Arm Section
5
ASSEMBLY STEP 1
USE ONLY THIS TYPE AND SIZE
BOLT
Washered Bolts 5/16"-18x1/2"
Sprocket
Mounting Plate
Front Tab Slot
Back Tab Slot
Sprocket Cover
Attach the Rail to the Motor Unit
To avoid installation difficulties, do not run the garage door opener until instructed to do so.
• Remove the two washered bolts mounted in top of motor unit.
• Position rail at a 45˚ angle to opener so one hole in rail and motor unit line up.
• Thread one of the washered bolts part way in.
Use only these bolts! Use of any other bolts will cause serious damage to door opener.
• Align rail and styrofoam over sprocket. Cut tape from rail, chain and styrofoam.
• REMOVE STYROFOAM.
To avoid SERIOUS damage to garage door opener, use ONLY those bolts/fasteners mounted in the top of the opener.
USE ONLY THIS TYPE AND SIZE
BOLT
Rail Hole
Washered Bolt 5/16"-18x1/2"
Styrofoam
ASSEMBLY STEP 2
Attach the Chain to the Sprocket and Install the Sprocket Cover
• Position chain over the sprocket. If necessary, loosen the outer nut on the trolley to obtain more chain slack.
• Insert the second washered bolt. CAUTION: Use only the bolt previously removed from motor unit!
• Tighten both bolts securely through the rail into the motor unit as shown.
• Install the sprocket cover: Insert the back tab in the slot. Squeeze the cover slightly and insert the front tab in the slot on the mounting plate.
To avoid possible SERIOUS INJURY to fingers from moving garage door opener:
• ALWAYS keep hand clear of sprocket while operating opener.
• Securely attach sprocket cover BEFORE operating.
6
ASSEMBLY STEP 3
WARNING
WARNING
WARNING WARNING
Tighten the Chain
• Spin the inner nut and lock washer down the trolley threaded shaft, away from the trolley.
• To tighten the chain, turn outer nut in the direction shown (Figure 1).
• When the chain is approximately 1/2" (13 mm) above the base of the rail at its midpoint, re-tighten the inner nut to secure the adjustment.
Sprocket noise can result if chain is too loose. When installation is complete, you may notice some chain
droop with the door closed. This is normal. If the chain returns to the position shown in Figure 2 when the door is open, do not re-adjust the chain.
NOTE: During future maintenance, ALWAYS pull the emergency release handle to disconnect trolley before adjusting chain. You may notice loosening of chain after Adjustment Step 3 (Test the Safety Reversal System). Check for proper tension and readjust chain if necessary. Then repeat Adjustment Step 3.
You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section.
Figure 1
Trolley
Figure 2
To Tighten Outer Nut
Chain
Base of Rail
Outer Nut
Mid Length of Rail
Lock Washer
1/2" (13 mm)
Inner Nut
To Tighten Inner Nut
INSTALLATION
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.
2. Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or more above floor.
6. Mount emergency release handle 6 feet (1.83 m) above floor.
7. NEVER connect garage door opener to power source until instructed to do so.
8. NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to garage door control.
11. Place manual release/safety reverse test label in plain view on inside of garage door.
12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor.
7
INSTALLATION STEP 1
Header Wall
Sectional door with curved track
Highest Point of Travel
Door
Track
2" (5 cm)
One-piece door with horizontal track
Door
Track
Header Wall
Highest Point of Travel
2" (5 cm)
Door
Jamb Hardware
One-piece door without track: jamb hardware
8" (20 cm)
Highest Point of Travel
Door
Pivot
8" (20 cm)
One-piece door without track: pivot hardware
Highest Point of Travel
Header Wall
Header Wall
Header Wall
Vertical Centerline of Garage Door
Level (optional)
2x4
2x4
Structural Supports
OPTIONAL CEILING MOUNT FOR HEADER BRACKET
Unfinished Ceiling
Determine the Header Bracket Location
To prevent possible SERIOUS INJURY or DEATH:
• Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might NOT reverse when required. DO NOT install header bracket over drywall.
• Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
• NEVER try to loosen, move or adjust garage door, springs, cables, pulleys, brackets, or their hardware, ALL of which are under EXTREME tension.
• ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance. An unbalanced garage door might NOT reverse when required.
Installation procedures vary according to garage door types. Follow the instructions which apply to your door.
1. Close the door and mark the inside vertical centerline of the garage door.
2. Extend the line onto the header wall above the door.
You can fasten the header bracket within 4 feet
(1.22 m) of the left or right of the door center only if a torsion spring or center bearing plate is in the way; or you can attach it to the ceiling (see page 9) when clearance is minimal. (It may be mounted on the wall upside down if necessary, to gain approximately 1/2" (1 cm).)
If you need to install the header bracket on a 2x4
(on wall or ceiling), use lag screws (not provided) to securely fasten the 2x4 to structural supports as shown here and on page 9.
3. Open your door to the highest point of travel as shown. Draw an inter secting horizontal line on the header wall above the high point:
2" (5 cm) above the high point for sectional door and
one-piece door with track.
8" (20 cm) above the high point for one-piece door
without track.
This height will provide travel clearance for the top
edge of the door.
NOTE: If the total number of inches exceeds the height
available in your garage, use the maximum height possible, or refer to page 9 for ceiling installation.
8
INSTALLATION STEP 2
Lag Screw 5/16"-9x1-5/8"
UP
Ceiling Mounting Holes
CEILING MOUNT ONLY
Lag Screws 5/16"-9x1-5/8"
Garage Door
– Finished Ceiling –
– Header Wall –
Header Bracket
6" (15 cm) Maximum
Door Spring
Vertical Centerline of Garage Door
Vertical Centerline of Garage Door
The nail hole is for positioning only. You must use lag screws to mount the header bracket.
Install the Header Bracket
You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. DO NOT install the header bracket over
drywall. If installing into masonry, use concrete anchors (not provided).
Wall Mounting Holes
CEILING MOUNT ONLY
UP
The nail hole is for positioning only. You must use lag screws to mount the header bracket.
WALL HEADER BRACKET INSTALLATION
• Center the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown (with the arrow pointing toward the ceiling).
• Mark the vertical set of bracket holes (do not use the holes designated for ceiling mount). Drill 3/16" pilot holes and fasten the bracket securely to a structural support with the hardware provided.
HARDWARE SHOWN ACTUAL SIZE
CEILING HEADER BRACKET INSTALLATION
• Extend the vertical centerline onto the ceiling as shown.
• Center the bracket on the vertical mark, no more than 6" (15 cm) from the wall. Make sure the arrow is pointing toward the wall. The bracket can be mounted flush against the ceiling when clearance is minimal.
• Mark the side holes. Drill 3/16" pilot holes and fasten bracket securely to a structural support with the hardware provided.
Horizontal Line
Header Wall
2x4 Structural Support
Highest Point of Garage Door Travel
Optional Wall Mounting Holes
Header Bracket
Vertical Centerline of Garage Door
Door Spring
Garage Door
Vertical Centerline of Garage Door
Lag Screws 5/16"-9x1-5/8"
9
Header Bracket
Chain Pulley Bracket
Temporary Support
Header Wall
Garage Door
Rail
Clevis Pin 5/16"x2-3/4"
Ring Fastener
Header Bracket
Chain Pulley Bracket
Rail
INSTALLATION STEP 3
Attach the Rail to the Header Bracket
• Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need
help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
• Position the rail bracket against the header bracket.
• Align the bracket holes and join with a clevis pin as shown.
• Insert a ring fastener to secure.
HARDWARE SHOWN ACTUAL SIZE
Clevis Pin 5/16"x2-3/4"
10
Ring Fastener
INSTALLATION STEP 4
Trolley
Release Arm
ENGAGED
RELEASED
Rail
Door
2x4 is used to determine the correct mounting height from ceiling.
Header Bracket
Top of Door
2x4 is used to determine the correct mounting height from ceiling.
Position the Opener
Follow instructions which apply to your door type as illustrated.
SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK
A 2x4 laid flat is convenient for setting an ideal door-to-rail distance.
• Remove foam packaging.
• Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
• Open the door all the way and place a 2x4 laid flat on the top section beneath the rail.
• If the top section or panel hits the trolley when you raise the door, pull down on the trolley release arm to disconnect inner and outer sections. Slide the outer trolley toward the motor unit. The trolley can remain disconnected until Installation Step 12 is completed.
To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door.
ONE-PIECE DOOR WITHOUT TRACK
A 2x4 on its side is convenient for setting an ideal door-to-rail distance.
• Remove foam packaging.
• Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
• Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
• The top of the door should be level with the top of the motor unit. Do not position the opener more than 4" (10 cm) above this point.
11
INSTALLATION STEP 5
Lag Screw 5/16"-18x1-7/8"
Hex Bolt 5/16"-18x7/8"
Nut 5/16"-18
Lock Washer 5/16"
Hang the Opener
Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener. This bracket and fastening hardware are not provided.
1. Measure the distance from each side of the motor unit to the structural support.
2. Cut both pieces of the hanging bracket to required lengths.
3. Drill 3/16" pilot holes in the structural supports.
4. Attach one end of each bracket to a support with 5/16"-18x1-7/8" lag screws.
5. Fasten the opener to the hanging brackets with 5/16"-18x7/8" hex bolts, lock washers and nuts.
6. Check to make sure the rail is centered over the door (or in line with the header bracket if the bracket is not centered above the door).
7. Remove the 2x4. Operate the door manually. If the door hits the rail, raise the header bracket.
8. Grease the top and underside of the rail surface where the trolley slides with rail grease.
NOTE: DO NOT connect power to opener at this time.
To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing ANY brackets into masonry.
Figure 1
Measure Distance
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Structural Supports
Lag Screws 5/16"-18x1-7/8"
Figure 2
Hidden Support
Bracket (Not Provided)
Lag Screws 5/16"-18x1-7/8"
FINISHED CEILING
HARDWARE SHOWN ACTUAL SIZE
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
Figure 3
Lag Screws 5/16"-18x1-7/8"
Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
FINISHED CEILING
(Not Provided) Bolt 5/16"-18x7/8" Lock Washer 5/16" Nut 5/16"-18
12
LOCK
LIGHT
KG
1
3
9
7
5
KG
1
3
9
7
5
INSTALLATION STEP 6
To release or insert wire, push in tab with screwdriver tip
Door Control Connections
7/16" (11 mm)
Strip wire 7/16" (11 mm)
Red
Grey
White
LOCK
LIGHT
Slot
Drywall Anchors
Insulated Staples
Screw 6ABx1-1/4" (standard installation)
Screw 6-32x1"(pre-wired)
LOCK
LIGHT
Install the Door Control
Locate door control within sight of door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of door and door hardware. The installation surface must be smooth and flat. If installing into drywall (Figure 1), drill 5/32" holes and use anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 2). NOTE: After installation, a green or amber
indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct).
1. Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to WHT and white/red wire to the RED (Figure 3).
2. Remove cover by gently prying at slot in the side of the cover with a small flat head screwdriver (Figure 4). Fasten with 6ABx1-1/4" self-tapping screws (drywall installation) or 6-32x1" machine screws (into gang box) as follows:
Drill and install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
Install top screw with care to avoid cracking plastic
housing. DO NOT overtighten.
Insert bottom tabs and snap on cover.
NOTE: The push bar may stick if the door control is not
mounted on a smooth surface. If a click is not heard when pressing the push bar, loosen the two mounting screws or relocate the door control to a smoother surface.
3. (Standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire. Connect bell wire to the quick-connect terminals as follows: white to white and white/red to red (Figure 5).
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into quick-connect holes: white to white and red/white to red.
5. Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.
NOTE: DO NOT connect power and operate opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is NOT connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
Figure 1
To Replace Insert Bottom Tabs First
Figure 3
STANDARD INSTALLATION
MULTI-FUNCTION DOOR CONTROL (BACK)
Top Mounting Hole Terminal
Screws
Bell Wire
Bottom Mounting Hole
Figure 2
To Replace Insert Bottom Tabs First
Figure 4
PRE-WIRED INSTALLATION
REMOVE COVER
24 Volt Bell Wire
Figure 5
13
INSTALLATION STEP 7
NOTICE
Install the Light
• Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens.
• Install a 100 watt maximum light bulb in each socket. Light bulb size should be A19, standard neck only. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF.
• Reverse the procedure to close the lens.
• Use A19, standard neck garage door opener bulbs for replacement.
NOTE: Use only standard light bulbs. The use of short neck or speciality light bulbs may overheat the endpanel or light socket.
To prevent possible OVERHEATING of the endpanel or light socket:
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent. To prevent damage to the opener:
• DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.
100 Watt (Max) Standard Light Bulb
Release Tab
Lens Hinge
INSTALLATION STEP 8
Attach the Emergency Release Rope and Handle
• Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up as shown. Secure with an overhand knot at least 1" (2.5 cm) from the end of the rope to prevent slipping.
• Thread the other end of the rope through the hole in the release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet (1.83 m) above the floor. Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement. Secure with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
Overhand Knot
Trolley
Rope
Trolley Release Arm
Emergency Release Handle
14
INSTALLATION STEP 9
RIGHT WRONG
Ground Tab
Green Ground Screw
Ground Wire
Black Wire
PERMANENT WIRING CONNECTION
White Wire
Black Wire
Electrical Requirements
To avoid installation difficulties, do not run the opener at this time.
To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn’t fit into the outlet you have, contact a qualified electrician to install the proper outlet.
If permanent wiring is required by your local code, refer to the following procedure.
To make a permanent connection through the 7/8" hole in the top of the motor unit:
• Remove the motor unit cover screws and set the cover aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.
• Reinstall the cover.
To avoid installation difficulties, do not run the opener at this time.
To prevent possible SERIOUS INJURY or DEATH from electrocution or fire:
• Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter, or change plug in ANY way to make it fit outlet. Be sure the opener is grounded.
15
Invisible Light Beam Protection Area
Safety Reversing Sensor 6" (15 cm) max. above floor
Safety Reversing Sensor 6" (15 cm) max. above floor
INSTALLATION STEP 10
Install The Protector System
The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR
When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye (with an amber indicator light) transmits an invisible light beam to the receiving eye (with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will flash 10 times.
The units must be installed inside the garage so that the sending and receiving eyes face each other across the door, no more than 6" (15 cm) above the floor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens.
The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware.
®
Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from a closing garage door:
• Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled.
• Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing. Extension brackets (see Accessories) are available if needed. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing.
Facing the door from inside the garage
16
INSTALLING THE BRACKETS
Wing Nut 1/4"-20
Staples
Carriage Bolt 1/4"-20x1/2"
Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows.
Garage door track installation (preferred):
• Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door. Snap into place against the side of the track. It should lie flush, with the lip hugging the back edge of the track, as shown in Figure 1.
If your door track will not support the bracket securely, wall installation is recommended.
Wall installation (Figure 2 & 3):
• Place the bracket against the wall with curved arms facing the door. Be sure there is enough clearance for the sensor beam to be unobstructed.
• If additional depth is needed, an extension bracket (see Accessories) or wood blocks can be used.
• Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, no higher than 6" (15 cm) above the floor.
• Attach brackets to wall with lag screws (not provided).
• If using extension brackets or wood blocks, adjust right and left assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared.
Floor installation (Figure 4):
• Use wood blocks or extension brackets (see Accessories) to elevate sensor brackets so the lenses will be no higher than 6" (15 cm) above the floor.
• Carefully measure and place right and left assemblies at the same distance out from the wall. Be sure all door hardware obstructions are cleared.
• Fasten to the floor with concrete anchors as shown.
Figure 1
Figure 2
Figure 3
(Provided with Extension Bracket)
DOOR TRACK MOUNT (RIGHT SIDE)
Door Track
Lip
Safety Reversing Sensor Bracket
WALL MOUNT (RIGHT SIDE)
Inside Garage Wall
WALL MOUNT (RIGHT SIDE)
Inside Garage Wall
Fasten Wood Block to Wall with Lag Screws (not provided)
Extension Bracket (See Accessories)
Lens
Indicator Light
Lens
Indicator Light
Lag Screws (not provided)
Lens
(Provided with Extension Bracket)
Safety Reversing Sensor Bracket
Indicator Light
Safety Reversing Sensor Bracket
HARDWARE SHOWN ACTUAL SIZE
Figure 4
17
FLOOR MOUNT (RIGHT SIDE)
Inside Garage
Wall
Lens
Attach with Concrete Anchors (not provided)
Indicator Light
Safety Reversing Sensor Bracket
Invisible Light Beam Protection Area
Safety Reversing Sensor
Safety Reversing Sensor
Connect Wire to Opener Quick-Connect Terminals
Bell Wire
Bell Wire
Finished Ceiling
1. Strip wire 7/16" (11 mm)
2. Twist like colored wires together
7/16" (11 mm)
Quick-Connect Terminals
3. To release or insert wire, push in tab with screwdriver tip
Red
Grey
White
Carriage Bolt 1/4"-20x1/2"
Lens
Wing Nut 1/4"-20
SENSORS
• Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).
• Finger tighten the wing nuts.
• Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling.
• Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener quick-connect terminals. Twist like colored wires together. Insert wires into quick­connect holes: white to white and white/black to grey (Figure 6).
ALIGNING THE SAFETY REVERSING SENSORS
• Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.
The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.
• Loosen the receiving eye wing nut and adjust sensor until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut.
Figure 5MOUNTING AND WIRING THE SAFETY REVERSING
TROUBLESHOOTING THE SAFETY REVERSING SENSORS
1. If the sending eye indicator light does not glow steadily after installation, check for:
Electric power to the opener.
A short in the white or white/black wires. These can
occur at staples, or at opener connections.
Incorrect wiring between sensors and opener.
A broken wire.
2. If the sending eye indicator light glows steadily but the receiving eye indicator light doesn’t:
Check alignment.
Check for an open wire to the receiving eye.
3. If the receiving eye indicator light is dim, realign either sensor.
NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. See page 16.
Figure 6
18
INSTALLATION STEP 11
Vertical Centerline
Door Bracket Location
Header Bracket
HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC). (NOT PROVIDED)
Door Bracket
Vertical Centerline of Garage Door
UP
Vertical Reinforcement
Self-Threading Screw 1/4"-14x5/8"
Self-Threading Screw 1/4"-14x5/8"
Door Bracket
Nut 5/16"-18
Bolt 5/16"-18x2" (Not Provided)
Lock Washer 5/16"
UP
Vertical Reinforcement
Vertical Centerline of Garage Door
UP
Self-Threading Screw 1/4"-14x5/8"
Vertical Centerline of Garage Door
UP
Inside Edge of Door or Reinforcement Board
Bolt 5/16"x2" (Not Provided)
Vertical Centerline of Garage Door
Fasten the Door Bracket
Follow instructions which apply to your door type as illustrated below or on the following page.
A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel.
Figure 1 shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit.
NOTE: Many door reinforcement kits provide for direct attachment of the clevis pin and door arm. In this case you will not need the door bracket; proceed to Step 12.
SECTIONAL DOORS
1. Center the door bracket on the previously marked vertical centerline used for the header bracket installation. Note correct UP placement, as stamped inside the bracket.
2. Position the top edge of the bracket 2"-4" (5-10 cm) below the top edge of the door, OR directly below any structural support across the top of the door.
3. Mark, drill holes and install as follows, depending on your door’s construction:
Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket:
• Drill 3/16" fastening holes. Secure the door bracket using the two 1/4"-14x5/8" self-threading screws (Figure 2A).
• Alternately, use two 5/16" bolts, lock washers and nuts (not provided) (Figure 2B).
Metal, insulated or light weight factory reinforced doors:
• Drill 3/16" fastening holes. Secure the door bracket using the self-threading screws (Figure 3).
Wood Doors:
• Use top and bottom or side to side door bracket holes. Drill 5/16" holes through the door and secure bracket with 5/16"x2" carriage bolts, lock washers and nuts (not provided) (Figure 4).
NOTE: The 1/4"-14x5/8" self-threading screws are not intended for use on wood doors.
HARDWARE SHOWN ACTUAL SIZE
Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket.
Contact your door manufacturer for reinforcement kit.
Figure 1
Figure 2B
Figure 2A
Figure 4
Figure 3
19
ONE-PIECE DOORS
Self-Threading Screw 1/4"-14x5/8"
Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also.
• Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes.
Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws provided.
Wood Doors: Drill 5/16" holes and use 5/16"x2" carriage bolts, lock washers and nuts (not provided) or 5/16"x1-1/2" lag screws (not provided) depending on your installation needs.
NOTE: The door bracket may be installed on the top edge of the door if required for your installation. (Refer to the dotted line optional placement drawing.)
Header Wall
2x4 Support
Header
Bracket
Door Bracket
Optional Placement of Door Bracket
Vertical Centerline of Garage Door
Finished Ceiling
HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED FOR LIGHTWEIGHT GARAGE DOORS (FIBERGLASS, ALUMINUM, STEEL, DOORS WITH GLASS PANEL, ETC.). (NOT PROVIDED)
HARDWARE SHOWN
ACTUAL SIZE
Door Bracket
Nut 5/16"-18
Door Bracket
Self-Threading Screw 1/4"-14x5/8"
Top of Door (Inside Garage)
Top Edge of Door
Optional Placement
METAL DOOR
Lock Washer 5/16"
Top of Door (Inside Garage)
Top Edge of Door
For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
20
Optional Placement
Carriage Bolt 5/16"x2" (Not Provided)
WOOD DOOR
INSTALLATION STEP 12
Ring Fastener
Door Bracket
Clevis Pin 5/16"x1-1/4"
Curved Door Arm
Straight Door Arm
Clevis Pin 5/16"x1"
Inner Trolley
Outer Trolley
Emergency Release Handle
Lock Washers 5/16"
Nuts 5/16"-18
Door Bracket
Bolts 5/16"-18x7/8"
Lock Washers 5/16"
Nuts 5/16"-18
Bolts 5/16"-18x7/8"
Cut This End
Lock Washer 5/16"
Nut 5/16"-18
Ring Fastener
Hex Bolt 5/16"-18x7/8"
Clevis Pin 5/16"x1" (Trolley)
Clevis Pin 5/16"x1-1/4" (Door Bracket)
Connect Door Arm to Trolley
Follow instructions which apply to your door type as illustrated below and on the following page.
SECTIONAL DOORS ONLY
Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" (5 cm) as shown in Figures 1, 2 and 3.
Figure 1:
• Fasten straight door arm section to outer trolley with the 5/16"x1" clevis pin. Secure the connection with a ring fastener.
• Fasten curved section to the door bracket in the same way, using the 5/16"x1-1/4" clevis pin.
IMPORTANT: The groove on the straight door arm MUST face away from the curved door arm (Figure 4).
Figure 2:
• Bring arm sections together. Find two pairs of holes that line up and join sections. Select holes as far apart as possible to increase door arm rigidity.
Figure 3, Hole alignment alternative:
• If holes in curved arm are above holes in straight arm, disconnect straight arm. Cut about 6" (15 cm) from the solid end. Reconnect to trolley with cut end down as shown.
• Bring arm sections together.
• Find two pairs of holes that line up and join with bolts, lock washers and nuts.
Pull the emergency release handle toward the opener at a 45° angle so that the trolley release arm is horizontal. Proceed to Adjustment Step 1, page 23. Trolley will re-engage automatically when opener is operated.
Figure 1
Figure 2
Figure 3
HARDWARE SHOWN ACTUAL SIZE
Figure 4
21
CORRECT INCORRECT
Straight Door Arm
(Groove facing out)
Curved Door Arm
Straight Door Arm
Curved Door Arm
ALL ONE-PIECE DOORS
Nuts 5/16"-18
Lock Washers 5/16"
Ring Fastener
Straight Arm
Bolts 5/16"-18x7/8
Door Bracket
Clevis Pin 5/16"x1-1/4"
Curved Door Arm
Door Arm
Door Arm Connector Hole
Closed Door
Outer Trolley
Emergency Release Handle
Inner Trolley
Outer Trolley
Open Door
Door Arm
Correct Angle
Door with Backward Slant (Incorrect)
Inner Trolley
1. Assemble the door arm, Figure 5: IMPORTANT: The groove on the straight door arm MUST
face away from the curved door arm (Figure 5).
Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap).
With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
Secure with a ring fastener.
2. Adjustment procedures, Figure 6:
On one-piece doors, before connecting the door arm to the trolley, the travel limits must be adjusted. Limit adjust ment screws are located on the left side panel as shown on page 23. Follow adjustment procedures below.
Open door adjustment: decrease UP travel limit
- Turn the UP limit adjustment screw counter-
clockwise 4 turns.
- Press the Door Control push button. The trolley will
travel to the fully open position.
- Manually raise the door to the open position (parallel
to the floor), and lift the door arm to the trolley. The arm should touch the trolley just in back of the door arm connector hole. Refer to the fully open trolley/ door arm positions in the illustration. If the arm does not extend far enough, adjust the limit further. One full turn equals 2" (5 cm) of trolley travel.
Closed door adjustment: decrease DOWN travel limit
- Turn the DOWN limit adjustment screw clockwise
4 complete turns.
- Press the Door Control push button. The trolley will
travel to the fully closed position.
Figure 5
Figure 5
CORRECT INCORRECT
Straight Door Arm
(Groove facing out)
Curved Door Arm
Straight Door Arm
Curved Door Arm
- Manually close the door and lift the door arm to the trolley. The arm should touch the trolley just ahead of the door arm connector hole. Refer to the fully closed trolley/door arm positions in the illustration. If the arm is behind the connector hole, adjust the limit further. One full turn equals 2" (5 cm) of trolley travel.
3. Connect the door arm to the trolley:
Close the door and join the curved arm to the
connector hole in the trolley with the remaining clevis pin. It may be necessary to lift the door slightly to make the connection.
Secure with a ring fastener.
Run the opener through a complete travel cycle. If the
door has a slight "backward" slant in full open position as shown in the illustration, decrease the UP limit until the door is parallel to the floor.
NOTE: When setting the up limit on the following page, the door should not have a "backward" slant when fully open as illustrated below. A slight backward slant will cause unnecessary bucking and/or jerking operation as the door is being opened or closed from the fully open position.
22
ADJUSTMENT STEP 1
Adjust the UP and DOWN Travel Limits
Limit adjustment settings regulate the points at which the door will stop when moving up or down.
To operate the opener, press the Door Control push bar. Run the opener through a complete travel cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse unintentionally when fully closed?
If your door passes both of these tests, no limit adjustments are necessary unless the reversing test fails (Adjustment Step 3, page 25).
Adjustment procedures are outlined below. Read the procedures carefully before proceeding to Adjustment Step 2. Use a screwdriver to make limit adjustments. Run
the opener through a complete travel cycle after each adjustment.
NOTE: Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off. Simply wait 15 minutes and try again. If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
Cover Protection Bolt
2-4" (5-10 cm)
HOW AND WHEN TO ADJUST THE LIMITS
• If the door does not open completely but opens at least five feet (1.5 m):
Increase up travel. Turn the UP limit adjustment screw
clockwise. One turn equals 2" (5 cm) of travel.
NOTE: To prevent the trolley from hitting the cover
protection bolt, keep a minimum distance of 2-4" (5 cm - 10 cm) between the trolley and the bolt.
• If door does not open at least 5 feet (1.5 m):
Adjust the UP (open) force as explained in Adjustment
Step 2.
• If the door does not close completely:
Increase down travel. Turn the DOWN limit adjustment
screw counterclockwise. One turn equals 2" (5 cm) of travel.
If door still won't close completely and the trolley
bumps into the pulley bracket (page 4), try lengthening the door arm (page 21) and decreasing the down limit.
• If the opener reverses in fully closed position:
Decrease down travel. Turn the DOWN limit adjustment
screw clockwise. One turn equals 2" (5 cm) of travel.
Left Side Panel Limit Adjustment Screws
Adjustment Label
• If the door reverses when closing and there is no visible interference to travel cycle:
If the opener lights are flashing, the Safety Reversing
Sensors are either not installed, misaligned, or obstructed. See Troubleshooting, page 18.
Test the door for binding: Pull the emergency release
handle. Manually open and close the door. If the door is binding or unbalanced, call for a trained door systems technician. If the door is balanced and not binding, adjust the DOWN (close) force. See Adjustment Step 2.
23
ADJUSTMENT STEP 2
Adjust the Force
Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door.
If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed.
The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls beyond that point. Turn force adjustment controls with a screwdriver.
NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel (including binding or unbalanced doors), it will reverse.
HOW AND WHEN TO ADJUST THE FORCES
1. Test the DOWN (close) force
• Grasp the door bottom when the door is about halfway through DOWN (close) travel. The door should reverse. Reversal halfway through down travel
does not guarantee reversal on a 1-1/2" (3.8 cm) obstruction. See Adjustment Step 3, page 25. If the
door is hard to hold or doesn’t reverse, DECREASE the DOWN (close) force by turning the control counterclockwise. Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.
If the door reverses during the down (close) cycle and the opener lights aren’t flashing, INCREASE DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase the
force beyond the minimum amount required to close the door.
2. Test the UP (open) force
• Grasp the door bottom when the door is about halfway through UP (open) travel. The door should stop. If the door is hard to hold or doesn’t stop, DECREASE UP (open) force by turning the control counterclockwise. Make small adjustments until the door stops easily and opens fully. After each adjustment, run the opener through a complete travel cycle.
If the door doesn’t open at least 5 feet (1.5 m), INCREASE UP (open) force by turning the control clockwise. Make small adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Too much force on garage door will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to close garage door.
• NEVER use force adjustments to compensate for a binding or sticking garage door.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.
Force Adjustment Controls
Back Panel
KG
KG
Antenna
FORCE ADJUSTMENT LABEL
9
7
5
KG
Open Force
9
1
3
7
Close Force
1
3
5
KG
24
ADJUSTMENT STEP 3
Test the Safety Reversal System
TEST
• With the door fully open, place a 1-1/2" (3.8 cm) board (or a 2x4 laid flat) on the floor, centered under the garage door.
• Operate the door in the down direction. The door must reverse on striking the obstruction.
ADJUST
• If the door stops on the obstruction, it is not traveling far enough in the down direction. Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1/4 turn.
NOTE: On a sectional door, make sure limit adjustments
do not force the door arm beyond a straight up and down position. See the illustration on page 21.
• Repeat the test.
• When the door reverses on the 1-1/2" (3.8 cm) board, remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment.
• If the unit continues to fail the Safety Reverse Test, call for a trained door systems technician.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on the floor.
IMPORTANT SAFETY CHECK:
Test the Safety Reverse System after:
• Each adjustment of door arm length, limits, or force controls.
• Any repair to or adjustment of the garage door (including springs and hardware).
• Any repair to or buckling of the garage floor.
• Any repair to or adjustment of the opener.
ADJUSTMENT STEP 4
Test The Protector System
• Press the remote control push button to open the door.
• Place the opener carton in the path of the door.
• Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm), and the opener lights will flash.
The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6" (15 cm) above the floor), call for a trained door systems technician.
®
1-1/2" (3.8 cm) board (or a 2x4 laid flat)
Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
25
Safety Reversing Sensor
Safety Reversing Sensor
OPERATION
WARNING
WARNING
WARNING WARNING
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel.
4. ALWAYS keep garage door in sight until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly, causing SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If rope knot becomes untied, you could fall.
Using Your Garage Door Opener
Your Security® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Your opener will operate with up to eight Security® remote controls and one Security® Keyless Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section.
Activate your opener with any of the following:
The hand-held Remote Control: Hold the large push button down until the door starts to move.
The wall-mounted Door Control: Hold the push button or bar down until the door starts to move.
The Keyless Entry (See Accessories): If provided with your garage door opener, it must be programmed before use. See Programming.
When the opener is activated (with the safety reversing sensor correctly installed and aligned)
1. If open, the door will close. If closed, it will open.
2. If closing, the door will reverse.
3. If opening, the door will stop.
4. If the door has been stopped in a partially open position, it will close.
5. If obstructed while closing, the door will reverse. If the obstruction interrupts the sensor beam, the opener lights will blink for five seconds.
9. If one control (force or travel limits) is adjusted, the other control may also need adjustment.
10. After ANY adjustments are made, the safety reversal system MUST be tested.
11. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor. Failure to adjust the garage door opener properly may cause SEVERE INJURY or DEATH.
12. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED (see page 3). An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
13. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.
14. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers.
15. SAVE THESE INSTRUCTIONS.
6. If obstructed while opening, the door will stop.
7. If fully open, the door will not close when the beam is
broken. The sensor has no effect in the opening cycle.
If the sensor is not installed, or is misaligned, the door won’t close from a hand-held remote. However, you can close the door with the Door Control, the Outside Keylock, or Keyless Entry, if you activate them until down travel is complete. If you release them too soon, the door will reverse.
The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption; when the opener is activated.
They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature on the Multi-Function Door Control is activated. Bulb size is A19. Bulb power is 100 watts maximum.
Security® light feature: Lights will also turn on when someone walks through the open garage door. With a Multi-Function Door Control, this feature may be turned off as follows: With the opener lights off, press and hold the light button for 10 seconds, until the light goes on, then off again. To restore this feature, start with the opener lights on, then press and hold the light button for 10 seconds until the light goes off, then on again.
26
Using the Wall-Mounted Door Control
THE MULTI-FUNCTION DOOR CONTROL
Press the push button to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening.
Light feature
LOCK
Press the Light button to turn the opener light on or off. It will not control the opener lights when the door is in motion. If you turn it on and then activate the opener, the light will remain on for 4-1/2 minutes. Press again to turn it off sooner. The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds). A single blink indicates that the timer is reset to 1-1/2 minutes. Repeat the procedure and the light will blink twice, resetting the timer to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval, etc., up to a maximum of four blinks and 4-1/2 minutes.
Lock feature
Designed to prevent operation of the door from hand-held remote controls. However, the door will open and close from the Door Control, the Outside Keylock and the Keyless Entry Accessories.
To activate, press and hold the Lock button for 2 seconds. The push bar light will flash as long as the Lock feature is on.
To turn off, press and hold the Lock button again for 2 seconds. The push bar light will stop flashing. The Lock feature will also turn off whenever the “learn” button on the motor unit panel is activated.
Push Button
Lock Button
Light
LIGHT
Button
To Open the Door Manually
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
The door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually. To reconnect the door to the opener, press the door control push bar.
Emergency Release Handle (Pull Down)
MANUAL DISCONNECT
POSITION
The lockout feature prevents the trolley from reconnecting automatically. Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. To disengage the lockout feature,
Emergency Release Handle (Down and Back)
LOCKOUT POSITION
pull the handle straight down. The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote.
Trolley Release Arm
NOTICE
Trolley Release Arm
NOTICE
27
CARE OF YOUR OPENER
FORCE CONTROLS
LIMIT CONTROLS
Battery positive side up (+)
LIMIT AND FORCE ADJUSTMENTS:
Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation.
Pages 23 and 24 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully.
Repeat the safety reverse test (Adjustment Step 3, page 25) after any adjustment of limits or force.
MAINTENANCE SCHEDULE
Once a Month
• Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
• Check to be sure door opens and closes fully. Adjust limits and/or force if necessary (see pages 23 and 24).
• Repeat the safety reverse test. Make any necessary adjustments (see Adjustment Step 3).
Twice a Year
• Check chain tension. Disconnect trolley first. Adjust if necessary (see page 7).
Once a Year
• Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.
THE REMOTE CONTROL BATTERY
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• DO NOT recharge, disassemble, heat above 100° C (212° F) or incinerate.
The lithium battery should produce power for up to 5 years.
To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+).
Dispose of old battery properly. Replace the battery with ONLY 3V2032 coin cell batteries.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
28
HAVING A PROBLEM?
Receiving Eye Safety Reversing Sensor (Green Indicator Light)
Sending Eye Safety Reversing Sensor (Amber Indicator Light)
Bell Wire
Safety Reversing Sensor
"Learn" Button LED or Diagnostic LED
1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be
connected and aligned correctly before the garage door opener will move in the down direction.
Verify the safety sensors are properly installed,
aligned and free of any obstructions. Refer to
Installation Step 10: Install The Protector System
Check diagnostic LED for flashes on the motor unit
then refer to the Diagnostic Chart on the following page.
2. My remotes will not activate the door:
Verify your door control is not blinking. If it is blinking,
deactivate the Lock Mode following the instructions for Using the Wall-Mounted Door Control.
Reprogram remotes following the programming
instructions. Refer to Programming.
If remote will still not activate your door, check
diagnostic LED for flashes on motor unit then refer to
Diagnostic Chart on the following page.
®
.
3. My door reverses for no apparent reason: Repeat safety reverse test after adjustments to force or travel limits. The need for occasional adjustment for the force and limit settings is normal. Weather conditions in particular can affect door travel.
Manually check door for balance or any binding
problems.
• Refer to Adjustment Step 2, Adjust the Force.
4. My door reverses for no apparent reason after fully closing and touching the floor: Repeat safety reverse
test after adjustments to force or travel limits. The need for occasional adjustment for the force and limit settings is normal. Weather conditions in particular can affect door travel.
Refer to Adjustment Step 1, Adjust the UP and
DOWN Travel Limits. Decrease down travel by turning down limit adjustment screw clockwise.
5. My lights will not turn off when door is open:
The garage door opener is equipped with a security
light feature. This feature activates the light on when the safety sensor beam has been obstructed. Refer to Operation section; Using the Wall Mounted Door
Control, Light Feature.
6. My motor unit hums briefly:
First verify that the trolley is against the stop bolt.
Release the door from the opener by pulling the Emergency Release Rope.
Manually bring the door to a closed position.
Loosen the chain by adjusting the outer nut 4 to 5 turns. This relieves the tension.
Run the motor unit from the remote control or door control. The trolley should travel towards the door and stop. If the trolley re-engages with the door, pull the Emergency Release Rope to disengage.
Decrease the UP travel by turning the UP Travel adjustment screw 2 full turns away from the arrow.
Re-tighten the outer nut so the chain is a 1/2" (13 mm) above the base of the rail. (When the door is reconnected and closed, the chain will sag. This is normal.)
If the trolley does not move away from the bolt, repeat the steps above.
29
Bell Wire
Safety Reversing Sensor
Diagnostics Located On Motor Unit
LED or Diagnostic LED
"Learn" Button
Installed
Safety Reversing
Sensor
Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below.
1 FLASH
Safety reversing sensors wire open (broken or disconnected).
OR
2 FLASHES
Safety reversing sensors wire shorted or black/ white wire reversed.
3 FLASHES
Door control or wire shorted.
4 FLASHES
Safety reversing sensors slightly misaligned (dim or flashing LED).
Symptom: One or both of the Indicator lights on the safety reversing sensors do not glow steady.
• Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/ white wires reversed), broken or disconnected wires, replace/attach as needed.
• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm) from back each of sensor.
• Reattach sending eye to motor unit using shortened wires. If sending eye indicator light glows steadily, attach the receiving eye.
• Align sensors, if the indicator lights glow replace the wires for the sensors. If the sensor indicator lights do not light, replace the safety reversing sensors.
Symptom: LED is not lit on door control.
• Inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together. If motor unit activates, replace door control.
• If motor unit does not activate, disconnect door control wires from motor unit. Momentarily short across red and white terminals with jumper wire. If motor unit activates, replace door control wires.
Symptom: Sending indicator light glows steadily, receiving indicator light is dim or flashing.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.
5 FLASHES
Symptom: Motor has over heated; the motor unit does not operate or trolley is stuck on stop bolt = Motor unit hums briefly; RPM Sensor =
Motor overheated or possible RPM sensor failure. Unplug to reset.
Short travel 6-8" (15-20 cm).
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM sensor.
• If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and retry.
6 FLASHES
Motor Circuit Failure. Replace Receiver Logic Board.
If motor unit still will not operate replace logic board.
Symptom: Motor unit doesn’t operate.
• Replace logic board because motor rarely fails.
30
PROGRAMMING
LOCK
LIGHT
LOCK
LIGHT
NOTICE: If this Security® garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
Your garage door opener has already been programmed at the factory to operate with your hand-held remote control. The door will open and close when you press the large push button.
Below are instructions for programming your opener to operate with additional Security® 315 MHz remote controls.
To Add or Reprogram a Hand-held Remote Control
USING THE “LEARN” BUTTON USING THE DOOR CONTROL
LOCK
LIGHT
1. Press and release the “learn” button on the motor unit. The learn indicator light will glow steadily for 30 seconds.
2. Within 30 seconds, press and hold the button on the hand-held remote* that you wish to operate your garage door.
3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
To Erase All Codes From Motor Unit
Memory
To deactivate any unwanted remote, first erase all codes:
Press and hold the “learn” button on motor unit until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased. Reprogram each remote or keyless entry you wish to use.
1. Press and hold the button on the hand-held remote* that you wish to operate your garage door.
2. While holding the remote button, press and hold the LIGHT button on the door control.
3. Continue holding both buttons while you press the push bar on the door control (all three buttons are held).
4. Release buttons when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
*3-Button Remotes
If provided with your garage door opener, the large button is factory programmed to operate it. Additional buttons on any Security remote or compact remote can be programmed to operate other Security garage door openers.
®
3-Button
®
31
To Add, Reprogram or Change a Keyless Entry PIN
LOCK
LIGHT
LOCK
LIGHT
LOCK
LIGHT
NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.
USING THE “LEARN” BUTTON USING THE DOOR CONTROL
1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds.
2. Within 30 seconds, enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold the ENTER button.
3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
To change an existing, known PIN
If the existing PIN is known, it may be changed by one person without using a ladder.
1. Press the four buttons for the present PIN, then press and hold the # button.
The opener light will blink twice. Release the # button.
2. Press the new 4-digit PIN you have chosen, then press Enter.
The motor unit lights will blink once when the PIN has been learned.
Test by pressing the new PIN, then press Enter. The door should move.
To set a temporary PIN
You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN:
1. Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the button.
The opener light will blink three times. Release the
button.
NOTE: This method requires two people if the Keyless Entry is already mounted outside the garage.
1. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER.
2. While holding the ENTER button, press and hold the LIGHT button on the door control.
3. Continue holding the ENTER and LIGHT buttons while you press the push bar on the door control (all three buttons are held).
4. Release buttons when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
2. Press the temporary 4-digit PIN you have chosen, then press Enter.
The opener light will blink four times.
3. To set the number of hours this temporary PIN will
work, press the number of hours (up to 255), then press .
OR
3. To set the number of times this temporary PIN will
work, press the number of times (up to 255), then press #.
The opener light will blink once when the temporary PIN has been learned.
Test by pressing the four buttons for the temporary PIN, then press Enter. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening. To clear the temporary password, repeat steps 1-3, setting the number of hours or times to 0 in step 3.
One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times when one button close is deactivated.
32
REPAIR PARTS
Rail Assembly Parts
1
5
2
Installation Parts
1
3
LOCK
LIGHT
3
4
KEY PART NO. NO. DESCRIPTION
1 4A1008 Master link kit 2 41A4813 Chain pulley bracket 3 41A3489 Complete trolley
6
assembly
4 1707LM One-piece rail
1708LM 8 ft. (2.4 m) complete rail
1710LM 10 ft. (3 m) complete rail 5 41D3484 Full chain assembly 6 83A11-2 Rail grease
2
4
KEY PART NO. NO. DESCRIPTION
NOTICE
12
Y L
N
T O
UN
O
M
CEILING
UP
7
5
2 371LM Single-button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope & handle
1 41A5273-1 Multi-function door control panel
6
assembly
6 41B4494-1 2-Conductor bell wire,
10
white & white/red 7 41A4353 Header bracket w/clevis pin & fastener 8 41A5047 Door bracket w/clevis pin & fastener
8
11
9 178B35 Curved door arm section 10 178B34 Straight door arm section 11 41A5034 Safety reversing sensor kit (receiving
and sending eyes) with 3 ft. (.9 m)
9
2-conductor bell wire 12 41A5266-1 Safety reversing sensor brackets (2)
NOT SHOWN
41A2770-6 Installation hardware bag
(includes hardware listed on page 5). 114A3588 Owner’s manual 114A3588SP Owner’s manual - Spanish
33
Motor Unit Assembly Parts
7
6
8
12
5
9
14
11
3
13
1
10
15
2
16
4
Drive Gear
Brown Wire
17
Center Limit Contact
18
(Down) Contact
DN
19
(Up) Contact
LIMIT SWITCH ASSY.
Grey Wire
UP
Yellow Wire
KEY PART NO. NO. DESCRIPTION
1 31D380 Sprocket cover 2 41C4220A Gear and sprocket assembly
Complete with: Spring washer, thrust washer, retaining ring, bearing plate, roll pins (2), drive gear and worm gear, helical gear w/retainer and grease
3 41A2817 Drive/worm gear kit w/grease,
roll pins (2) 4 41B4245 Line cord 5 41A5484-1 End panel w/all labels 6 4A1344 Light socket 7 108D79 Lens 8 30B532 Capacitor - 1/2 HP
30B533 Capacitor - 1/3 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w/screws 11 41D3058 Universal replacement motor &
bracket assembly
Complete with: Motor, worm,
bracket, bearing assembly, RPM
sensor
KEY PART NO. NO. DESCRIPTION
12 41A5525-24 Cover 13 41A2818 Limit switch drive & retainer 14 41D3452 Limit switch assembly 15 41A2822-1 Interrupter cup assembly 16 41C4398A RPM sensor assembly 17 41AC050-1M Receiver logic board.
Complete with: Logic board,
end panel w/all labels 18 41C5498 Low voltage wire harness. 41C5497 High voltage wire harness. 19 41D180-1 End panel w/all labels
NOT SHOWN
41A2826 Motor shaft bearing kit 41A2825 Opener assembly hardware
kit (includes screws not designated by a number in illustration)
34
ACCESSORIES
CLOSED
OPEN
LOCK
LIGHT
CLOSED
OPEN
1702LM Outside Quick Release:
Required for a garage with NO access door. Enables homeowner to open garage door manually from outside by disengaging trolley.
41A5281
Extension Brackets:
(Optional) For safety sensor installation onto the wall or floor.
377LM
Wireless Keyless Entry with Security®:
Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons. This temporary password can be limited to a programmable number of hours or entries.
373P
374LM
370LM
378LM
SECURITY® 3-Button Remote Control :
Includes visor clip.
Security® 4-Button Remote Control :
Includes visor clip.
3-Button Mini-Remote Control with Security® :
With key ring and fastening strip.
Wireless Door Control:
Push bar, light feature and auxiliary button. Includes battery.
915LM
395LM
Garage Door Monitor:
Security for the largest door of your home!
Tells you if your garage door is open or closed. Monitors up to 4 garage doors by adding additional sensor modules.
Remote Light Control:
Enables homeowner to turn on a lamp, television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional LiftMaster Security
®
remote.
975LM
990LM
Laser Park Assist:
Laser enables homeowners to precisely park vehicles in the garage.
Surge Protector:
The Garage Door Opener Surge Protector is designed to protect LiftMaster
®
garage door openers against damage from lightning and power surges.
35
LIFTMASTER® SERVICE IS
ON CALL
HOW TO ORDER
REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA AND CANADA
INSTALLATION AND SERVICE INFORMATION IS AS NEAR
AS YOUR TELEPHONE.
SIMPLY DIAL OUR TOLL FREE NUMBER:
1-800-528-9131
www.liftmaster.com
For professional installation, parts and service, contact
your local LIFTMASTER/CHAMBERLAIN dealer. Look for him
in the Yellow Pages, or call our Service number for a list of
dealers in your area.
Selling prices will be furnished on request or parts will be
shipped at prevailing prices and you will be billed
accordingly.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
PART NUMBER
PART NAME
MODEL NUMBER ADDRESS ORDERS TO:
THE CHAMBERLAIN GROUP, INC.
Technical Support Group
6050 S. Country Club Road
Tucson, Arizona 85706
SERVICE INFORMATION
TOLL FREE NUMBER:
1-800-528-9131
LIFTMASTER® ONE-YEAR LIMITED WARRANTY
FOUR YEAR MOTOR LIMITED WARRANTY
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase [and that the motor is free from defect in materials and/or workmanship for a period of four years from the date of purchase]. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE ONE-YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR, WHICH ARE LIMITED IN DURATION TO THE FOUR-YEAR LIMITED WARRANTY PERIOD FOR THE MOTOR], AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some States do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
© 2010, The Chamberlain Group, Inc. 114A3588B All Rights Reserved
Loading...