SAFETY
Safety Symbol and Signal Word Review
When you see these Safety Symbols and Signal Words on the following pages, they will alert
you to the possibility of Serious Injury or Death if you do not comply with the warnings that
accompany them. The hazard may come from something mechanical or from electric shock.
Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of
damage to your gate and/or the gate operator if you do not comply with the cautionary
statements that accompany it. Read them carefully.
IMPORTANT NOTE:
• BEFORE attempting to install, operate or maintain the operator, you must read and fully
understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are an Authorized
Service Technician.
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
2
MECHANICAL
ELECTRICAL
SAFETY
Usage Class
Class I - Residential Vehicular Gate Operator
A vehicular gate operator (or system) intended for use in garages or
parking areas associated with a residence of one-to four single families.
Class II - Commercial/General Access Vehicular
Gate
A vehicular gate operator (or system) intended for use in a commercial
location or building such as a multi-family housing unit (five or more
single family units), hotel, garages, retail store, or other buildings
accessible by or servicing the general public.
Class III - Industrial/Limited Access Vehicular
Gate
A vehicular gate operator (or system) intended for use in an industrial
location or building such as a factory or loading dock area or other
locations not accessible by or intended to service the general public.
Class IV - Restricted Access Vehicular Gate
Operator
A vehicular gate operator (or system) intended for use in a guarded
industrial location or building such as an airport security area or other
restricted access locations not servicing the general public, in which
unauthorized access is prevented via supervision by security personnel.
UL325 Entrapment Protection Requirements
l
A minimum of two independent* monitored entrapment protection
devices are required to be installed at each entrapment zone
l Every installation is unique. It is the responsibility of the installer to
install external monitored entrapment protection devices in each
entrapment zone
l This vehicular slide gate operator will operate only after installation
of a minimum of two independent* monitored entrapment protection
devices in each direction; two in the open direction and two in the
close direction.
l Entrapment protection device types include inherent (built into the
operator), monitored external photoelectric sensors or monitored
external edge sensors
l This operator is provided with an inherent entrapment protection
device built into the operator that serves as one of the two
independent devices
* Independent - the same type of device shall NOT be used for both
entrapment protection devices.
IMPORTANT SAFETY
To reduce the risk of INJURY or DEATH:
l READ AND FOLLOW ALL INSTRUCTIONS.
l NEVER let children operate or play with gate controls. Keep the
remote control away from children.
l ALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
l Test the gate operator monthly. The gate MUST reverse on contact
with an object or reverse when an object activates the noncontact
sensors. After adjusting the force or the limit of travel, retest the
gate operator. Failure to adjust and retest the gate operator properly
can increase the risk of INJURY or DEATH.
l Use the emergency release ONLY when the gate is not moving.
l KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
Have a qualified service person make repairs to gate hardware.
l The entrance is for vehicles ONLY. Pedestrians MUST use separate
entrance.
INSTRUCTIONS
l SAVE THESE
INSTRUCTIONS.
3
Safety Installation Information
SAFETY
1. Vehicular gate systems provide convenience and security. Gate systems
are comprised of many component parts. The gate operator is only one
component. Each gate system is specifically designed for an individual
application.
2. Gate operating system designers, installers and users must take into
account the possible hazards associated with each individual
application. Improperly designed, installed or maintained systems can
create risks for the user as well as the bystander. Gate systems design
and installation must reduce public exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a
component part of a gate system. Therefore, safety features must be
incorporated into every design. Specific safety features include:
l Edges Sensors (contact)
l Guards for Exposed Rollers
l Photoelectric Sensors
l Screen Mesh
l Vertical Posts
l Instructional and Precautionary Signage
4. Install the gate operator only when:
a. The operator is appropriate for the construction and the usage
class of the gate.
b. All openings of a horizontal slide gate are guarded or screened
from the bottom of the gate to a minimum of 6 feet (1.8 m) above
the ground to prevent a 2-1/4 inches (6 cm) diameter sphere from
passing through the openings anywhere in the gate, and in that
portion of the adjacent fence that the gate covers in the open
position.
c. All exposed pinch points are eliminated or guarded, and guarding
is supplied for exposed rollers.
5. The operator is intended for installation only on gates used for
vehicles. Pedestrians must be supplied with a separate access opening.
The pedestrian access opening shall be designed to promote pedestrian
usage. Locate the gate such that persons will not come in contact with
the vehicular gate during the entire path of travel of the vehicular gate.
6. The gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment.
7. The gate must be properly installed and work freely in both directions
prior to the installation of the gate operator.
8. Permanently mounted access controls intended for users to activate,
must be located at least 6 feet (1.8m) away from any moving part of
the gate and where the user is prevented from reaching over, under,
around or through the gate to operate the controls. Outdoor or easily
accessible controls shall have a security feature to prevent unauthorized
use. Exception: Emergency access controls only accessible by
authorized personnel (e.g. fire, police) may be placed at any location in
the line-of-sight of the gate.
9. The Stop and/or Reset (if provided separately) must be located in the
line-of-sight of the gate. Activation of the reset control shall not cause
the operator to start.
10. A minimum of two (2) WARNING SIGNS shall be installed in the area
of the gate. Each placard is to be visible by persons located on the side
of the gate on which the placard is installed.
11. For a gate operator utilizing a non-contact sensor:
a. Reference owner’s manual regarding placement of non-contact
sensor for each type of application. See Install Entrapment
Protection section.
b. Care shall be exercised to reduce the risk of nuisance tripping,
such as when a vehicle trips the sensor while the gate is still
moving.
c. One or more non-contact sensors shall be located where the risk of
entrapment or obstruction exists, such as the perimeter reachable
by a moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor:
a. One or more contact sensors shall be located where the risk of
entrapment or obstruction exists, such as at the leading edge,
trailing edge and post mounted both inside and outside of a
vehicular horizontal slide gate.
b. A hard wired contact sensor shall be located and its wiring
arranged so the communication between the sensor and the gate
operator is not subject to mechanical damage.
c. A wireless device such as one that transmits radio frequency (RF)
signals to the gate operator for entrapment protection functions
shall be located where the transmission of the signals are not
obstructed or impeded by building structures, natural landscaping
or similar obstruction. A wireless device shall function under the
intended end-use conditions.
4
SAFETY
Gate Construction Information
Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy,
contact ASTM directly at 610-832-9585 or www.astm.org.
1.General Requirements
1.1Gates shall be constructed in accordance with the provisions
given for the appropriate gate type listed, refer to ASTM F2200
for additional gate types.
1.2Gates shall be designed, constructed and installed to not fall
over more than 45 degrees from the vertical plane, when a
gate is detached from the supporting hardware.
1.3Gates shall have smooth bottom edges, with vertical bottom
edged protrusions not exceeding 0.50inches (12.7 mm) when
other than the exceptions listed in ASTM F2200.
1.4The minimum height for barbed tape shall not be less than 8
feet (2.44m) above grade and for barbed wire shall not be
less than 6 feet (1.83m) above grade.
1.5An existing gate latch shall be disabled when a manually
operated gate is retrofitted with a powered gate operator.
1.6A gate latch shall not be installed on an automatically operated
gate.
1.7Protrusions shall not be permitted on any gate, refer to ASTM
F2200 for Exceptions.
1.8Gates shall be designed, constructed and installed such that
their movement shall not be initiated by gravity when an
automatic operator is disconnected, in accordance with the
following.
1.8.1Vehicular horizontal slide gate. Shall not result in continuous,
unimpeded movement in either lineal direction of its travel.
1.9For pedestrian access in the vicinity of an automated vehicular
gate, a separate pedestrian gate shall be provided. The
pedestrian gate shall be installed in a location such that a
pedestrian shall not come in contact with a moving vehicular
access gate. A pedestrian gate shall not be incorporated into
an automated vehicular gate panel.
2.Specific Applications
2.1Any non-automated gate that is to be automated shall be
upgraded to conform to the provisions of this specification.
2.2This specification shall not apply to gates generally used for
pedestrian access and to vehicular gates not to be automated.
2.3When the gate operator requires replacement, the existing gate
shall be upgraded to conform to the provisions of this
specification.
2.4When the gate of an automated gate system requires
replacement, the new gate shall conform to the provisions of
this specification.
3.Vehicular Horizontal Slide Gates
3.1The following provisions shall apply to Class I, Class II and Class III
vehicular horizontal slide gates:
3.1.1All weight bearing exposed rollers 8feet (2.44m), or less, above
grade shall be guarded or covered.
3.1.2All openings shall be designed, guarded, or screened from the
bottom of the gate to the top of the gate or a minimum of 6 ft.
(1.83m) above grade, whichever is less, to prevent a 2 1⁄4in.
(57mm) diameter sphere from passing through the openings
anywhere in the gate, and in that portion of the adjacent fence that the
gate covers in the open position. The gate panel shall include the
entire section of the moving gate,including any back frame or
counterbalance portion of the gate.
3.1.3A gap, measured in the horizontal plane parallel to the roadway,
between a fixed stationary object nearest the roadway, (such as a gate
support post) and the gate frame when the gate is in either the fully
open position or the fully closed position, shall not exceed 2
1/4inches (57mm). Exception: All other fixed stationary objects
greater than 16 in. (406 mm) from the gate frame shall not be
required to comply with this section.
3.1.4Positive stops shall be required to limit travel to the designed fully
open and fully closed positions. These stops shall be installed at
either the top of the gate, or at the bottom of the gate where such
stops shall horizontally or vertically project no more than is required
to perform their intended function.
3.1.5All gates shall be designed with sufficient lateral stability to assure
that the gate will enter a receiver guide, refer to ASTM F2200 for
panel types.
3.2The following provisions shall apply to Class IV vehicular horizontal
slide gates:
3.2.1All weight bearing exposed rollers 8feet (2.44m), or less, above
grade shall be guarded or covered.
3.2.2Positive stops shall be required to limit travel to the designed fully
open and fully closed positions. These stops shall be installed at
either the top of the gate, or at the bottom of the gate where such
stops shall horizontally or vertically project no more than is required
to perform their intended function.
When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated
208/240/480/575 VAC, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH
24 Vdc Transformer Run / Battery Backup
24 Vdc, 500mA max. for ON + SW (switched)
24 Vdc at 60 watts max.
1500 lbs. (680.4 kg)
4 feet (1.2 m)
50 feet (15.24 m)
1 foot/second
Continuous
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Provided
Main board - up to 2 close entrapment protection devices and 1 open entrapment
protection device.
Expansion board - up to 3 entrapment protection devices configurable to either close or
open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU .
7
INTRODUCTION
Site Preparation
Check the national and local building codes BEFORE installation.
Conduit and Concrete Pad
Trench and install conduit. Before trenching, contact underground
utility locating companies. Conduit must be UL approved for low
and high voltage. Consider the operator placement BEFORE
installing the pad or post.
Gate
Gate must be constructed and installed according to ASTM F2200
standards (refer to page 4). Gate must fit specifications of operator
(refer to specifications).
Safety
Entrapment protection devices are required to protect against any entrapment or
safety conditions encountered in your gate application. Install a warning sign
(two provided) on the inside and outside of the property, where easily visible.
Additional Accessories
The vehicle loops allow the gate to stay open when vehicles are obstructing the
gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are
not required but are recommended. Before installing your Access Control
Device(s) be sure to complete a site survey and determine the best device for
your site needs.
8
INSTALLATION
l To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging more
than 18 inches (46 cm) deep.
l ALWAYS wear protective gloves and eye protection when changing
the battery or working around the battery compartment.
Types of Installations
Standard InstallationRear Installation
9
INSTALLATION
Step 1 Determine Location for Operator
Check the national and local building codes before installation.
Standard Installation
1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad.
2. Install the electrical conduit.
3. Pour a concrete pad (reinforced concrete is recommended).
Rear Installation
1. The gate operator should be installed near the back of the gate in the OPEN position. Lay out the concrete pad.
2. Install the electrical conduit.
3. Pour a concrete pad (reinforced concrete is recommended).
10
INSTALLATION
Step 2 Install the Operator
Attach the operator to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of
the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches (10.2 cm). NOTE: An alternative to a
concrete pad is to post mount the operator (refer to Accessories).
11
INSTALLATION
Step 3 Attach the Chain
Standard Installation
DO NOT run the operator until instructed.
1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in
this position.
2. Manually close the gate and line up the rear bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the rear bracket in
this position.
3. Route the chain through the operator.
4. Connect the chain to the brackets using the eye bolt hardware. Chain should not be too tight or have excessive slack.
5. Remove the pin from the vent plug on the gear box.
NOTE: The chain should have no more than 1 inch (2.5 cm) of sag for every 10 feet (3 m) of chain length.
12
Idler Pulley MUST have
safety cover.
Pin
Vent Plug
INSTALLATION
Rear Installation
DO NOT run the operator until instructed.
NOTE: This installation will require two extra idler pulleys. Make sure all exposed pinch points are guarded. Refer to Gate Construction Information on page
4.
1. Move the back pulley to the bottom hole in the operator.
2. Manually close the gate and align the bottom bracket so the chain will be level with the bottom idler pulley and parallel to the ground. Weld the bottom
bracket in this position.
3. Align the top bracket so the chain will be level with the top idler pulley and parallel to the ground. Weld the upper bracket in this position.
4. Route the chain through the operator.
5. Connect the chain to the brackets using the eye bolt hardware. Chain should not be too tight or have excessive slack.
6. Remove the pin from the vent plug on the gear box.
NOTE: The chain should have no more than 1 inch (2.5 cm) of sag for every 10 feet (3 m) of chain length.
13
INSTALLATION
To prevent SERIOUS INJURY or DEATH from a moving gate:
l ALL gate operator systems REQUIRE two independent entrapment
protection systems for each entrapment zone.
l Entrapment protection devices MUST be installed to protect anyone
who may come near a moving gate.
Step 4 Install Entrapment Protection
Entrapment protection MUST be installed according to the following UL
325 requirements:
l
Slide gate operators require a minimum of two external monitored
entrapment protection devices to function; one in the open direction
and one in the close direction.
l Every installation is unique. It is the responsibility of the installer to
ensure that ALL entrapment zones are protected with an external
monitored entrapment protection device, protecting both the open
and close gate cycles.
l LiftMaster monitored external entrapment protection devices MUST
be used with LiftMaster operators to meet UL325 requirements,
see Accessories.
l Test ALL entrapment protection devices after completing installation
of the operator. For testing instructions, refer to the manual provided
with your entrapment protection device.
l Locate entrapment protection devices to protect in BOTH the open and
close gate cycles.
l Locate entrapment protection devices to protect between moving gate
and RIGID objects, such as posts, walls, pillars, columns, or operator
itself.
Definitions
ENTRAPMENT: The condition when a person is caught or held in a
position that increases the risk of injury.
SLIDE GATE ENTRAPMENT ZONE: An entrapment zone exists if at any
point during travel, the gap between the gate and any opposing fixed edge
or surface such as posts, walls, pillars, columns or operator itself, is less
than 16" (406 mm) in a location up to 6 ft. (1.8 m) above grade.
Illustrations provided by DASMAGate Systems Safety Guide
14
INSTALLATION
Wire Entrapment Protection Devices
There are three options for wiring the entrapment protection devices depending on the specific device and how the device will function. Refer to the specific
entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed
photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored entrapment protection device may be wired to each input.
Additional entrapment protection devices may be wired to the expansion board.
Control Board
CLOSES EYES/INTERRUPT
(2 Terminals) The CLOSE EYES/INTERRUPT input is for photoelectric
sensor entrapment protection for the close direction. When an
obstruction is sensed during gate closing the gate will open to the full
open position and resets the Timer-to-Close. This input will be
disregarded during gate opening.
CLOSE EDGE
(2 Terminals) The CLOSE EDGE input is for edge sensor entrapment
protection for the close direction. When an obstruction is sensed during
gate closing the gate will reverse to the full open position, disengaging
the Timer-to-Close. This input will be disregarded during gate opening.
OPEN EYES/EDGE
(2 Terminals) The OPEN EYES/EDGE input is for photoelectric sensor or
edge sensor entrapment protection for the open direction. When an
obstruction is sensed during gate opening the gate will reverse for 4
seconds then stop. This input will be disregarded during gate closing.
Expansion Board
EYE ONLY and COM
Open or Close Direction Photoelectric Sensors, the functionality is based
on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
15
INSTALLATION
Step 5 Earth Ground Rod
Use the proper earth ground rod for your local area. The ground wire
must be a single, whole piece of wire. Never splice two wires for the
ground wire. If you should cut the ground wire too short, break it, or
destroy its integrity, replace it with a single wire length.
1. Install the earth ground rod within 3 feet (.9 m) of the operator.
2. Run wire from the earth ground rod to the operator.
NOTE: If the operator is not grounded properly the range of the remote
controls will be reduced and the operator will be more susceptible to
lightning and surge damage.
Step 6 Power Wiring
To reduce the risk of SEVERE INJURY or DEATH:
l ANY maintenance to the operator or in the area near the operator
MUST NOT be performed until disconnecting the electrical power (AC
or solar and battery) and locking-out the power via the operator power
switch. Upon completion of maintenance the area MUST be cleared
and secured, at that time the unit may be returned to service.
l Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with
national and local electrical codes. NOTE: The operator should be on a
separate fused line of adequate capacity.
The operator can be wired for either 120 Vac or 240 Vac or a solar panel (not provided). Follow the directions according to your application. An
optional Transformer Kit (Model 3PHCONV) can be used to change the input voltage (208/240/480/575 Vac) to an output voltage of 120 Vac (refer to
Accessories). For dual gate applications, power will have to be connected to each operator. Main power supply and control wiring MUST be run in
separate conduits.
SOLAR APPLICATIONS: For solar applications refer to Solar Panels section in the Appendix. Follow the directions according to your application.
NOTE: If using an external receiver use shielded wire for the connections and mount the receiver away from the operator to avoid interference from the
operator.
l ALL electrical connections MUST be made by a qualified individual.
l DO NOT install ANY wiring or attempt to run the operator without
consulting the wiring diagram.
l ALL power wiring should be on a dedicated circuit and well protected.
The location of the power disconnect should be visible and clearly
labeled.
l ALL power and control wiring MUST be run in separate conduit.
1,400 (426.7m)1,900 (579.1m)7,600
(2,316.5m)
11,300
(3,444.2m)
18,000
3,700
(1,127.8m)
(3,688.1m)
4,800 (1,463m)19,300
(5,882.6m)
(5,486.4m)
28,500
(8,686.8m)
16
INSTALLATION
All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
240 VAC only
The accessory outlet is disabled and cannot be used with the 240 Vac option.
1. Remove the outlet housing from the electrical box by removing the screws (2).
2. Pull the outlet housing out and locate the power wiring connector on the EMI board.
3. Unplug the power wiring connector from the 120 Vac socket (factory default location) and plug it into the 240 Vac socket.
4. Replace the outlet housing by securing with the screws. The operator is now set for 240 Vac operation.
120 VAC and 240 VAC
1. Turn off the AC power from the main power source circuit breaker.
2. Run the AC power wires to the operator.
3. Remove the junction box cover.
4.
Connect the green wire to the earth ground rod and AC ground using a wire nut. NOTE: The earth ground rod can be grounded to the chassis.
5. Connect the white wire to NEUTRAL using a wire nut.
6. Connect the black wire to HOT using a wire nut.
7. Replace the junction box cover. Ensure the wires are not pinched.
17
INSTALLATION
AC power switch
The AC Power switch on the operator will turn the incoming 120/240 Vac power ON or OFF. The operator's AC Power switch ONLY turns off AC power to
the control board and DOES NOT turn off battery power.
Step 7 Connect Batteries
7AH battery
The batteries are charged in the circuit by the integrated transformer. The
batteries are for battery backup.
1. Turn OFF AC power to the operator.
2. Unplug the J15 plug labeled BATT on the control board by
squeezing the plug and pulling it from the control board. This
disconnects the ac/dc power to the control board.
3. Connect a jumper between the positive (+) terminal of one battery to
the negative terminal (-) of the other battery.
4. Connect the red wire from the J15 plug to the positive (+) terminal
of the battery.
5. Connect the black wire from the J15 plug to the negative (-) terminal
of the battery.
6. Plug the J15 plug back into the control board. This will power up
the control board. NOTE: You may see a small spark when plugging
the J15 plug into the board.
7. Turn ON AC power to the operator.
8. Turn ON the AC power switch on the operator.
18
INSTALLATION
33AH battery
The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar installation. The 33AH application
requires the Solar Harness Kit (Model K94-37236) and an additional battery tray (Model K10-34758-2).
1. Locate the J15 plug on the control board and disconnect it.
2. Connect the white jumper from the Solar Harness Kit between the positive (+) terminal of one battery and the negative (-) terminal of the other battery.
3. Connect one end of the red (+) wire from the Solar Harness Kit to the red wire from the J15 plug as shown. Connect the other end of the red (+) wire
to the positive (+) terminal on the battery as shown.
4. Connect one end of the black (-) wire from the Solar Harness Kit to the black wire from the J15 plug as shown. Connect the other end of the black (-)
wire to the negative (-) terminal on the battery as shown.
5. Turn ON AC power to the operator.
6. Turn ON the AC power switch on the operator.
7.
Reconnect the J15 plug to the control board. NOTE: You may see a small spark when plugging the J15 plug into the board.
19
INSTALLATION
Step 8 Dual gate setup
There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and
wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications.
Wireless setup
To activate the wireless feature:
1.
Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. NOTE: We
recommend that all accessories and board configurations are set on the primary operator.
2.
Press and release the LEARN button on the primary operator. The green XMITTER LED will light. NOTE: The operator will time out of programming
mode after 180 seconds.
3. Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light.
4. Press and release the OPEN test button to assign this operator as network primary.
5. Press and release the LEARN button on the second operator. The green XMITTER LED will light.
6. Press and release the LEARN button again on the second operator. The yellow NETWORK LED will light.
7. Press and release the CLOSE test button to assign this operator as network second.
Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful.
To deactivate the wireless feature:
1. Press and release the LEARN button on either operator. The green XMITTER LED will light.
2. Press and release the LEARN button again on the same operator. The yellow NETWORK LED will light.
3. Press and hold the LEARN button for 5 seconds. The yellow NETWORK LED will blink (operator will beep) then turn off indicating successful
deactivation.
4. Repeat the steps for the other operator.
20
INSTALLATION
Wired setup
Before digging, contact local underground utility locating companies. Use
PVC conduit to prevent damage to cables.
1. Disconnect ALL power to the operator and unplug the J15 plug from
the control board.
2. Trench across driveway to bury the shielded twisted pair cable.
3. Connect the wires from the shielded twisted pair cable to the Com Link
terminals on the primary gate operator control board. NOTE: We
recommend that all accessories and board configurations are set on
the primary operator.
4. Route the shielded twisted pair cable to the secondary gate operator's
control board.
5. Connect the wires from the shielded twisted pair cable to the Com Link
terminals on the secondary control board (Com Link A to Com Link A
and Com Link B to Com Link B). Ground the shield of the cable to the
chassis ground of one operator.
6. Connect ALL power to the operator and plug the J15 plug into the
control board.
DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE)
22AWG up to 200feet (61m)18AWG - 200-1000feet (61-305m)
Wire must be rated at 30 Volt minimum
Bipart delay/synchronized close
The LOCK/BIPART DELAY switch is used only with dual gate applications and serves two functions:
l
BIPART DELAY
SWING GATE APPLICATIONS: The BIPART DELAY is used in applications where a mag-lock, solenoid lock, or decorative overlay would require one
gate to close before the other. The operator with the LOCK/BIPART DELAY switch ON will delay from the close limit when opening and be the first to
close from the open limit.
SLIDE GATE APPLICATIONS: Not applicable, set to OFF.
l
SYNCHRONIZED CLOSE
The BIPART DELAY is also used in applications where one gate travels a longer distance than the other. To synchronize the closing of the gates, set the
LOCK/BIPART DELAY switch to ON for both operators.
21
INSTALLATION
Step 9 Install the cover
Before installing the cover, follow the instructions in the Adjustment section to adjust the limits and force.
The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access the
reset switch slide the access door up. The front cover and access door can be locked with the key.
1. Align the tabs on the rear cover with the slots on the chassis and
place the cover over the operator.
2. Secure both sides of the rear cover to the chassis with two 5/16-18
lead in screws.
3. Align the front cover with the back cover, making sure the grooves
line up.
4. Secure the front cover to the chassis with two 5/16-18 lead in
screws.
5. Secure the front cover to the rear cover using the 5/16-18 lead in
screw.
To Lock the Access Door
From the factory the access door for the reset switch will not be locked.
To lock the access door follow the steps below:
1. Locate the lock tab on the back of the front cover and remove the
screw securing the tab to the cover.
2. Turn the tab 180 degrees, then secure with the screw. The access
door can now be locked.
The basic installation is complete.
22
ADJUSTMENT
Limit and Force Adjustment
To reduce the risk of SEVERE INJURY or DEATH:
l Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a moving gate.
l Too much force on gate will interfere with proper operation of safety
reversal system.
l NEVER increase force beyond minimum amount required to move
gate.
l NEVER use force adjustments to compensate for a binding or sticking
gate.
l If one control (force or travel limits) is adjusted, the other control
may also need adjustment.
l After ANY adjustments are made, the safety reversal system MUST be
tested. Gate MUST reverse on contact with an object.
Introduction
Your operator is designed with electronic controls to make travel limit
and force adjustments easy. The adjustments allow you to program
where the gate will stop in the open and close position. The electronic
controls sense the amount of force required to open and close the gate.
The force is adjusted automatically when you program the limits but
should be fine tuned using the REVERSAL FORCE dial on the control
board (refer to Fine Tune the Force section) to compensate for
environmental changes. The limit setup LEDs (located next to the SET
OPEN and SET CLOSE buttons) indicate the status of the limits, refer to
the table to the right.
The limits can be set using the control board (below) or a remote control
(refer to Limit Setup with a Remote Control in the Appendix). Setting the
limits with a remote control requires a 3-button remote control
programmed to OPEN, CLOSE, and STOP.
NOTE: The TEST buttons on the control board will not work until the
limits have been set and the required entrapment protection devices are
installed.
Initial Limits and Force Adjustment
For dual gate applications the limits will have to be set for each
operator. The gate MUST be attached to the operator before setting
the limits and force.
For slide gate applications the open limit and closed limit MUST be set
at least four feet apart.
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter limit setting mode.
2. Press and hold one of the MOVE GATE buttons to move the gate to
the open or close limit.
3. Press and release the SET CLOSE or SET OPEN button depending
on which limit is being set.
4. Press and hold one of the MOVE GATE button to move the gate to
the other limit.
5. Press and release the SET CLOSE or SET OPEN button depending
on which limit is being set.
6. Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit
setting mode.
LIMIT SETUP LEDS
SET
OPEN
LED
SET
CLOSE
LED
OPERATOR
MODE
EXPLANATION
OFFOFFNORMAL MODELimits are set
BLINKING BLINKING LIMIT SETTING
Limits are not set
MODE
BLINKINGONLIMIT SETTING
Open limit is not set
MODE
ONBLINKINGLIMIT SETTING
Close limit is not set
MODE
ONONLIMIT SETTING
Limits are set
MODE
23
ADJUSTMENT
Fine Tune the Force
Once the initial limits have been set, the REVERSAL FORCE DIAL on the
control board is used for fine tuning the force where wind or
environmental changes may affect the gate travel. The REVERSAL FORCE
DIAL is set to minimum at the factory.
Based on the length and weight of the gate it may be necessary to make
additional force adjustments. The force setting should be high enough
that the gate will not reverse by itself nor cause nuisance interruptions,
but low enough to prevent serious injury to a person. The force setting is
the same for both the open and close gate directions.
1. Open and close the gate with the TEST BUTTONS.
2. If the gate stops or reverses before reaching the fully open or closed
position, increase the force by turning the force control slightly
clockwise.
3. Perform the “Obstruction Test” after every limit and force setting
adjustment (see below).
Adjust the Limits
After both limits are set and the operator is ready to run, one limit can be
adjusted independently from the other by following steps 1-3 of the
Initial Limit and Force Adjustment section.
Obstruction Test
The operator is equipped with an inherent (built in to the operator)
obstruction sensing device. If the gate encounters an obstruction during
motion, the operator will reverse direction of the gate and then stop. The
following procedure will test ONLY the inherent (built in to the operator)
obstruction sensing device:
1. Open and close the gate with the TEST BUTTONS, ensuring that the
gate is stopping at the proper open and close limit positions.
2. Place an object between the open gate and a rigid structure. Make
sure that any external entrapment protection devices will NOT be
activated by the object.
3. Run the gate in the close direction. The gate should stop and reverse
upon contact with the object. If the gate does not reverse off the
object, reduce the force setting by turning the force control slightly
counter-clockwise. The gate should have enough force to reach both
the open and close limits, but MUST reverse after contact with an
object.
4. Repeat the test for the open direction.
Test the operator after any adjustments are made.
24
PROGRAMMING
Remote Controls (Not Provided)
A total of 50 Security+ 2.0®remote controls or KPW250 keypads and 2
keyless entries (1 PIN for each keyless entry) can be programmed to the
operator. When programming a third keyless entry to the operator, the
first keyless entry will be erased to allow the third keyless entry to be
programmed. When the operator’s memory is full it will exit the
programming mode and the remote control will not be programmed. The
memory will need to be erased before programming any additional
remote controls. NOTE: If installing an 86LM to extend the range of the
remote controls DO NOT straighten the antenna.
There are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a
programming option:
OPTIONDESCRIPTIONPROGRAMMING STEPS
Single button as OPEN
only
Single button (SBC) as
OPEN, CLOSE, and STOP
Three separate buttons as
OPEN, CLOSE, and STOP
Program a single button on the remote
control for open only. The Timer-to-Close
can be set to close the gate.
Program one remote control button as an
open, close, and stop.
Program each remote control button as an
open, close, and stop.
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light). NOTE: The operator will time out of
programming mode after 30 seconds.
2. Press the OPEN button.
3. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light). NOTE: The operator will time out of
programming mode after 30 seconds.
2. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light). NOTE: The operator will time out of
programming mode after 30 seconds.
2. Press the OPEN, CLOSE, or STOP button, depending on the desired
function.
3. Press the remote control button that you would like to program.
The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program
additional Security+ 2.0®remote controls or remote control buttons, repeat the programming steps above.
Entering programming mode using external reset button or 3-button control station:
1. Make sure gate/door is closed.
2. Give the operator an OPEN command.
3. Within 30 seconds, when the gate/door is at the open limit press and release the RESET/STOP button twice to put the operator into programming
mode. NOTE: The operator will time out of programming mode after 30 seconds.
NOTICE: This devicecomplies with Part 15 of the FCC rules and Industry Canada’s license-exempt RSSs.Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance cou ld void the user’s auth ority to operate the equipment.
This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between users/bystanders and device.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules and Industry Canada ICES standard. T hese limit s aredesigned
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with th e instructions, may cause harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation. If this
equipment do es cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Co nnect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Co nsult th e dealeror an experienced radio/TV t echnician for help.
25
PROGRAMMING
LiftMaster Internet Gateway (not
provided)
To program the operator to the LiftMaster Internet Gateway:
Using the learn button on the opertaor's control
board
1. Connect the ethernet cable to the LiftMaster Internet Gateway and the
router.
2. Connect power to the LiftMaster Internet Gateway.
3. Create an online account by visiting www.myliftmaster.com.
4. Register the LiftMaster Internet Gateway.
5. Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6. Press the Learn button twice on the primary operator (the operator will
beep as it enters learn mode). The LiftMaster Internet Gateway will pair
to the operator if it is within range and the operator will beep if
programming is successful.
Using the reset button on the operator
1. Connect the ethernet cable to the LiftMaster Internet Gateway and the
router.
2. Connect power to the LiftMaster Internet Gateway.
3. Create an online account by visiting www.myliftmaster.com.
4. Register the LiftMaster Internet Gateway.
5. Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6. Ensure gate is closed.
7. Give the operator an OPEN command.
8. Within 30 seconds, when the gate is at the open limit press and release
the reset button 3 times (on primary gate) to put primary operator into
High Band Learn Mode (the operator will beep as it enters learn mode).
The LiftMaster Internet Gateway will pair to the operator if it is within
range and the operator will beep if programming is successful.
The status as shown by the LiftMaster Internet Gateway app will be either
“open” or “closed”. The gate operator can then be controlled through the
LiftMaster Internet Gateway app.
Erase All Codes
1. Press and release the LEARN button (operator will beep and green
XMITTER LED will light).
2. Press and hold the LEARN button again until the green XMITTER LED
flashes and then release the button (approximately 6 seconds). All
remote control codes are now erased.
Erase Limits
1. To erase the limits, press and hold the SET OPEN and SET CLOSE
buttons simultaneously (5 seconds) until both the SET OPEN and SET
CLOSE LEDs blink rapidly and the operator beeps.
2. Release the buttons and the SET OPEN and SET CLOSE LEDs will blink
slowly indicating the limits will need to be set.
Constant Pressure Override (CPO)
Constant Pressure Override is for use with KPW5 and KPW250 keypads
(not provided). The KPW5/KPW250 wireless commercial keypads are
security keypads and can only be programmed to ONE gate operator (see
the KPW5/KPW250 manual for complete programming instructions).
The Constant Pressure Override feature is intended to temporarily override a
fault in the entrapment protection system, in order to operate the gate until
the external entrapment protection device is realigned or repaired. Use the
feature only in line of sight of the gate when no obstructions to travel are
present. External entrapment protection devices include LiftMaster
monitored photoelectric sensors and LiftMaster monitored wired and
wireless edge sensors. Be sure to repair or replace these devices promptly if
they are not working properly.
To use Constant Pressure Override:
1. Enter a valid 4-digit PIN.
2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to
keep the operator in motion. A continuous tone will sound until limit is
met and/or # is released.
3. The operator will stop when either the operator reaches a limit or the
user releases #.
Gate Hold Open Feature
The gate hold open feature will disable the timer and keep the gate at the
open limit. The gate hold open feature can be activated through the Reset
Button as described on Page 29 or through the KPW5 and KPW250
keypads (not provided).
To use the gate hold open feature:
1. Enter a valid 4-digit PIN when the gate is at the Open Limit and the
timer is running
2. The Operator will chirp indicating the timer is canceled.
To restart the gate:
1. Re-enter the 4-digit PIN
2. Activate a Hard input or a programmed remote
To Remove and Erase Monitored
Entrapment Protection Devices
1. Remove the entrapment protection device wires from the terminal
block.
2. Press and release the SET OPEN and SET CLOSE buttons
simultaneously. The SET OPEN and SET CLOSE LEDs will turn on
(entering learn limit mode).
3. Press and release both SET OPEN and SET CLOSE buttons again to
turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit
mode).
26
OPERATION
Gate operator setup examples
The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access
trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
SETTINGRESIDENTIAL
Quick Close switch
setting
AC Fail Open switch
setting
Low Batter y switch
setting
Anti-Tail switch setting
Bipart Delay switch
setting
Aux Relay O ut – Open
Limit Switch
Aux Relay O ut – Close
Limit Switch
Aux Relay O ut – Gate
Motion
Aux Relay O ut – PreMotion Delay
Aux Relay O ut – Power
Aux Relay O ut – Tamper
(Slide Gates Only)
Cycle Quantity Feedback
Fire Dept Open Input
Heater Accessory
(Model HTR)
Normally set toOFF. Normal gate
close (timer or control).
Normally set toBATT. R un on
battery if AC power fails.
Normally set toOPEN. If powered
from battery and battery is low,
gate automatically opens andstays
open.
Normally set toOFF. CLOSE
EYES/Interrupt loop reverses a
closinggate.
For DUAL-G ATE site, set toON for
gate that delays uponopening.
Typically not required.Use with SAMS (Sequence Access
Typically not required.Typically not required.Connect “Gate Close/Secure”
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach visual alert toknow when
system is chargingbatteries (i.e.
not running on batteries).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
beingpushed off of close limit.
Use duringservicingonly to
determine operator cycles.
Typically not required.Connect emergency access
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below-4°F. The thermostat MUST
be set between 45°F and60°F to
ensure proper gate operation.
COMMERCIAL/GENERAL
ACCESS
Normally set toOFF. Normal gate
close (timer or control).
Normally set toBATT. For local
jurisdictionrequirement, set to
OPEN so that the gate willopen
approximately 15 seconds after AC
power fail.
Normally set toOPEN. If powered
from battery and battery is low,
gate automatically opens andstays
open.
Normally set toOFF. CLOSE
EYES/Interrupt loop reverses a
closinggate.
For DUAL-G ATE site, set toON for
gate that delays uponopening.
Management System).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach visual alert toknow when
system is chargingbatteries (i.e.
not running on batteries).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
beingpushed off of close limit.
Use duringservicingonly to
determine operator cycles.
system (Knox box switch, SOS
system, etc.).
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below-4°F. The thermostat MUST
be set between 45°F and60°F to
ensure proper gate operation.
COMMERCIALINDUSTRIAL
Normally set toOFF. Normal gate
close (timer or control).
Normally set toBATT. R un on
battery if AC power fails.
Normally set toCLOSE. If powered
from battery and battery is low,
gate stays closed.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interruptlooppauses a closing
gate.
For DUAL-G ATE site, set toON for
gate that delays uponopening.
1. Use withSAMS (Sequence
Access Management
System).
2. Connect “Gate Open”
indicator (e.g. light).
indicator (e.g. light).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach visual alert toknow when
system is chargingbatteries (i.e.
not running on batteries).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
beingpushed off of close limit.
Use duringservicingonly to
determine operator cycles.
Typically not required.Typically not required.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below-4°F. The thermostat MUST
be set between 45°F and60°F to
ensure proper gate operation.
Set to ON, so that gate closes
immediately after vehicle passes
CLOSE EYES/Interrupt loop.
Normally set toBATT. R un on
battery if AC power fails.
Normally set toCLOSE. If powered
from battery and battery is low,
gate stays closed.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interruptlooppauses a closing
gate.
For DUAL-G ATE site, set toON for
gate that delays uponopening.
1. Use withSAMS (Sequence
Access Management
System).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach visual alert toknow when
system is chargingbatteries (i.e.
not running on batteries).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
beingpushed off of close limit.
Use duringservicingonly to
determine operator cycles.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below-4°F. The thermostat MUST
be set between 45°F and60°F to
ensure proper gate operation.
27
OPERATION
Control Board Overview
1 SET OPEN Button: The SET OPEN button sets the OPEN limit. See Adjust Limits section.
2 SET CLOSE Button: The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
3 MOVE GATE Buttons: The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
4 BATT FAIL:
l When AC power is OFF and battery voltage is critically low the gate will latch at a limit until AC power is restored or batteries voltage increases.
l Option select switch set to OPEN forces gate to automatically open and then latch at the OPEN limit until AC power is restored or battery voltage
increases.
l Option select switch set to CLOSE forces gate to latch at CLOSE limit if at CLOSE limit or on next CLOSE command until AC power restored or battery
voltage increases.
l Constant pressure on a hard command input overrides to open or close the gate.
l Critically low battery is less than 23 V
5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section.
6 LEARN Button: The LEARN button is for programming remote controls and the network.
7 TIMER-TO-CLOSE dial: The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to
OFF. If the TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the TIMER-TOCLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF. NOTE: Any radio command, single button control, or CLOSE command
on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from the open controls, loops, close edges, and close
photoelectric sensors (IR’s).
8 REVERSAL FORCE dial: The REVERSAL FORCE dial fine tunes the force. See Force Adjustment section.
9 TEST BUTTONS: The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
10 STATUS LEDs: The STATUS LEDs indicate the status of the operator. See Status LED Chart in the Troubleshooting section.
11 DIAGNOSTICS Display: The diagnostics display will show the operator type, firmware version, and codes. The operator type will display as "SL"
followed by a "24" which indicates the operator type as CSL24UL. The firmware version will show after the operator type, example "1.2".
12 BACKDRIVE Switch: Set to MANUAL will allow the gate to be manually pushed open or closed if there is a loss of AC and battery power. Set to
SECURE makes the gate difficult to push open or closed if there is a loss of AC and battery power.
28
Reset/Disconnect
Normal operation
OPERATION
Manual Disconnect
Press the reset switch to RESET/DISCONNECT. Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate
application the handle must be released on both operators. To resume normal function tighten the handle by pushing it down.
Reset Switch
The reset switch is located on the front of the operator and serves several
functions.
Toggling the reset switch will stop a moving gate during a normal open/
close cycle, like a stop button. The operator does not need to be reset
after doing this. The reset switch will disable the gate in the present
position and will energize the solenoid lock for two minutes and disable
the maglock for two minutes.
Operator Alarm
If a contact sensor detects an obstruction twice consecutively the alarm
will sound (up to 5 minutes) and the operator will need to be reset.
When the inherent force of the operator (RPM/current sensor) detects the
following (twice consecutively) the alarm will sound (up to 5 minutes)
and the operator will need to be reset.
A. The gate is hitting a wall or vehicle.
B. The gate does not meet specifications.
C. Debris is on the gate's track such as mud, rocks, dirt, etc.
D. The gate has one or more broken axles or wheels.
E. The gate wheel is off the gate rail.
Remove any obstructions. Press the reset button to shut off the alarm and
reset the operator. After the operator is reset, normal functions will
resume.
The operator alarm will beep 3 times with a command if the battery is
low.
Remote control
Single Button Control (SBC) Functionality
Once the remote control has been programmed the operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote
control will stop the gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will close the gate. If the remote control is activated while the gate is closing,
the gate will stop and the next activation will open the gate.
29
ACCESSORY WIRING
All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
External control devices
EXIT (2 Terminals)
This input is a soft open command (maintained switch does not override
external safeties and does not reset alarm condition). Used for exit probe,
telephone entry, external exit loop detector, or any device that would
command the gate to open.
l Opens a closing gate and holds open an open gate, if maintained,
pauses Timer-to-Close at OPEN limit.
SHADOW (2 Terminals)
This input is used for external shadow loop detector when loop is
positioned under the swing of the gate.
l Holds open gate at open limit
l Only active when the gate is at the OPEN limit, disregarded at all
other times
l Pauses Timer-to-Close at OPEN limit
INTERRUPT (2 Terminals)
This input is used for photoelectric sensors and external interrupt loop
detector when loop is on the outside of the gate.
l Holds open gate at open limit
l Stops and reverses a closing gate to open limit
l Pauses Timer-to-Close at OPEN limit, activates quick close and anti-
tailgate features when enabled on the expansion board
Access control device wiring
Loop wiring
30
ACCESSORY WIRING
Locks
Maglock (2 Terminals, N.C. and COM)
Relay contact output, Normally - closed (N.C.) output for maglocks.
Relay activates prior to motor activation and during motor run. Relay is
off when motor is off.
Miscellaneous wiring
Three button control station (4 Terminals)
l OPEN and COM: Opens a closed gate. Hard open (maintained switch
overrides external safeties and resets alarm condition). If maintained, pauses
Timer-to-Close at OPEN limit. Opens a closing gate and holds open an open
gate (within line-of-sight).
l CLOSE and COM: Closes an open gate. Hard close (maintained switch
overrides external safeties and resets alarm condition within line-of-sight)
l STOP and COM: Stops a moving gate. Hard stop (maintained switch
overrides Open and Close commands and resets alarm condition). If
maintained, pauses Timer-to-Close at OPEN limit. Overrides Open and Close
commands (within line-of-sight).
Fire department open input (2 Terminals)
Acts as hard open.
Maintained input overrides (ignores) external safeties (photoelectric sensor and
edge), pauses Timer-to-Close momentary input logic as single button control
and safeties remain active, re-enables Timer-to-Close.
Accessory power 24 VDC, MAX 500 mA (4 Terminals)
l SWITCHED: Switched ON with gate motion and at the open limit when
Timer-to-Close is active. Turns off 5 seconds after motion.
l UNSWITCHED: 24 Vdc voltage out to power accessories, always ON.
31
EXPANSION BOARD
l To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.
Expansion board overview
1. QUICK CLOSE switch:
OFF: No change to the gate's normal operation.
ON: When CLOSE EYES/Interrupt loop is deactivated it causes an
opening or a stopped gate to close (ignores the Timer-to-Close).
2. AC FAIL switch:
OPEN: Loss of AC power will cause the gate to open approximately 15
seconds after AC power fail and remain OPEN until AC power is
restored (enabling the Timer-to-Close).
BATT: With loss of AC power, gate will remain in present position and
operator is powered from batteries.
3. EXIT FAIL switch:
When set to OPEN, if the EXIT plug-in loop detector (Model
LOOPDETLM) detects a fault, then the gate will open and remain open
until fault is cleared. When set to CLOSE, then plug-in EXIT loop
detector faults are ignored (EXIT loop is faulted and inoperative).
4. ANTI-TAIL switch:
OFF: When CLOSE EYES/Interrupt loop is activated it causes a closing
gate to stop and reverse.
ON: When CLOSE EYES/Interrupt loop is activated it causes a closing
gate to pause. Once the vehicle is clear the gate will continue to close.
5. AUX RELAY switches:
Set the AUX RELAY switches as needed to obtain the desired function
as shown on the following page.
6. EYE/EDGE switches:
Set the EYE/EDGE switches as needed to obtain the desired OPEN or
CLOSE functionality.
7. 1, 2, and 3 LEDs:
LEDs indicating the status of the EYE/EDGE inputs. Also used to check
the firmware version of the expansion board:
1. Locate the 1, 2, and 3 LEDs on the expansion board.
2. Disconnect AC/DC power to the main control board for 15
seconds.
3. Connect power. The 1, 2, and 3 LEDs will flash in sequence until
the main control board firmware revision is displayed. When the
green POWER LED glows solid the LED 1 will flash the version
number, then stop, then the LED 2 will flash the revision number
(for example: For version 5.1 when the green POWER LED is solid
the LED 1 will flash 5 times, then stop, then the LED 2 will flash
once).
8. MAIN BOARD input:
Input Connection for the main board connector.
9. Input LEDs:
LEDs indicating the status of the SBC, OPN, CLS, and STP inputs.
10. Loop detector inputs:
Inputs for the Plug-In Loop Detectors (Model LOOPDETLM)
11. Wireless edge input:
Input for the Wireless Edge Kit (Model LMWEKITU)
32
EXPANSION BOARD
Auxiliary relay 1 and 2
Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5
Amps) power sources only. Function of relay contact activation determined by switch settings.
AUX RELAY
SETTING
Off (no feature
selected)
Open Limit Switch
Close Limit Switch
Gate Motion
Pre-Motion Delay
Power
Tamper
Cycle Quantity
Feedback*
SWITCH SETTINGS
123
OFFOFFOFF Relay always off. Use this Aux Relay setting to conserve battery power.
OFFOFF ON
OFF ONOFF
OFF ONON
ONOFFOFF
ONONOFF
ONOFF ON
ONONON
Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier
gate).
Energizes when not at close limit. For an additional audible or visual display, connect an external light (low
voltage).
Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an
external buzzer or light (low voltage).
Energizes 3 seconds before gate motion and
remains energized during gate motion. The onboard
alarm will sound. For an additional audible or visual
display, connect an external buzzer or light (low
voltage).
Energizes when AC power or solar power is present.
There is approximately a 10-12 second delay before
relay cutoff, after AC shutdown.
Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible or
visual display, connect an external buzzer or light (low voltage).
The 1, 2, and 3 LEDs will blink out the cycle count
(cycle count is stored on the control board). See
below.
AUX RELAY 1AUX RELAY 2
Energizes 3 seconds before gate motion and
remains energized during gate motion. For an
additional audible or visual display, connect an
external buzzer or light (low voltage).
Energizes when on battery power. There is
approximately a 10-12 second delay before relay
cutoff, after AC shutdown.
Red/green light functionality, see below.
* Cycle count
First, note the current Aux Relay switch positions. To determine the
actual cycles that the gate operator has run (in thousands), set all three
Aux Relay switches to the ON setting for Aux Relay 1. The Expansion
Board’s 1, 2, and 3 LEDs will blink out the cycle count, with 1 LED
blinking 1000’s, 2 LED blinking 10,000’s, 3 LED blinking 100,000’s, and
simultaneously all three LED’s blink 1,000,000’s (e.g. 1 LED blinks 3
times, 2 LED blinks 6 times, and 3 LED blinks once. Cycle count is
163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles.
After servicing, set Aux Relay switches back to their appropriate
positions. Cycle count cannot be reset or changed. If under 1,000 cycles
the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off.
NOTE: The expansion board will flash the cycle count 3 times then all the
LEDs will turn on solid for 10 seconds then turn off.
Auxiliary relay wiring example
RED/GREEN LIGHT FUNCTIONALITY
Red light wired to AUX RELAY 1. Green light wired to AUX RELAY 2.
AUX RELAY 1
GATE STATE
Closed
Opening
Open
Closing
Defined Mid Stop
Undefined Mid Stop
Timer more than 5
seconds
Timer less than 5
seconds
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to
SWITCHES
1 OFF 2 OFF 3 OFF1 ON2 ON3 ON
Red light OFF*Green light OFF
Red light ON/FlashGreen light OFF
Red light OFFGreen light ON
Red light ON/FlashGreen light OFF
n/an/a
Red light ONGreen light OFF
Red light OFFGreen light ON
Red light ON/FlashGreen light OFF
ON
AUX RELAY 2
SWITCHES
33
EXPANSION BOARD
Wiring accessories to the expansion board
Refer to the chart below and the corresponding image for a description of the expansion board inputs.
1Wireless edge
2Entrapment Protection Device
Inputs (4 terminals total), Open or
Close Direction based on switch
setting next to inputs
3Single Button Control, SBC (2
terminals)
4Open Input (& common) (3-Button
Control Station, 4 terminals total)
5Close Input (& common) (3-Button
Control Station, 4 terminals total)
6Stop Input (& common) (3-PB
station, 4 terminals total)
7Exit Loop Input (2 terminals)
8Shadow Loop Input (2 terminals)
9Interrupt Loop Input (2 terminals)
Connection for wireless edge receiver
EYES ONLY Input: Open or Close Direction Photoelectric Sensors, Close: reverses fully, Open: reverses 4
seconds
EYES/EDGE Input(s): Open or Close Direction Photoelectric Sensors, Infra-red detector wired or Edge
switch does not override external safeties and does not reset alarm condition)
Open command - opens a closed gate.
Soft open (maintained switch does not override external safeties and does not reset alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate.
Close command - closes an open gate.
Soft close (maintained switch does not override external safeties and does not reset alarm condition).
Stop command - stops a moving gate.
Hard stop (maintained switch overrides Open and Close commands and resets alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Overrides an Open or Close command.
Loop wire connection for plug-in loop detector when loop is inside secured area near gate.
Open command - opens a closed gate.
Soft open (maintained switch does not override external safeties and does not reset alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate.
Loop wire connection for plug-in loop detector when loop is positioned under the gate.
l Holds open gate at open limit
l Disregarded during gate motion
l Pauses Timer-to-Close at Open Limit
Loop wire connection for plug-in loop detector when loop is along the side of the gate.
l Holds open gate at open limit
l Stops and reverses a closing gate
l Pauses Timer-to-Close at Open Limit
34
MAINTENANCE
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
l READ AND FOLLOW ALL INSTRUCTIONS.
l ANY maintenance to the operator or in the area near the operator
MUST NOT be performed until disconnecting the electrical power
(AC or solar and battery) and locking-out the power via the operator
power switch. Upon completion of maintenance the area MUST be
cleared and secured, at that time the unit may be returned to service.
l Disconnect power at the fuse box BEFORE proceeding. Operator
MUST be properly grounded and connected in accordance with
national and local electrical codes. NOTE: The operator should be on
a separate fused line of adequate capacity.
l NEVER let children operate or play with gate controls. Keep the
remote control away from children.
l ALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
l The entrance is for vehicles ONLY. Pedestrians MUST use separate
entrance.
l Test the gate operator monthly. The gate MUST reverse on contact
with an object or reverse when an object activates the noncontact
sensors. After adjusting the force or the limit of travel, retest the gate
operator. Failure to adjust and retest the gate operator properly can
increase the risk of INJURY or DEATH.
l Use the manual disconnect release ONLY when the gate is NOT
moving.
l KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual.
Have a qualified service person make repairs to gate hardware.
l ALL maintenance MUST be performed by a LiftMaster professional.
l Activate gate ONLY when it can be seen clearly, is properly adjusted
and there are no obstructions to gate travel.
l To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster
part 29-NP712 for replacement batteries.
l SAVE THESE INSTRUCTIONS.
l ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
Maintenance Chart
Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC Power switch ONLY turns off AC power to the control
board and DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.
DESCRIPTIONTASKCHECK AT LEAST ONCE EVERY
MONTH6 MONTHS3 YEARS
Entrapment Protection Devices
Check and test inherent (built into the operator) and external devices for
proper operation
Warning Signs
Make sure they are present and replace if worn or broken, see Accessories
Manual DisconnectCheck and test for proper operationX
Sprockets and ChainsCheck for excessive slack and lubricateX
GateInspect for wear or damage; ensure it still complies with ASTM F2200, see
page 5
AccessoriesCheck all for proper operationX
ElectricalInspect all wire connectionsX
Chassis Mounting BoltsCheck for tightnessX
OperatorInspect for wear or damageX
BatteriesReplace
NOTES:
l Severe or high cycle usage will require more frequent maintenance checks.
l Limits may have to be reset after any major drive chain adjustments.
l If lubricating chain, use only lithium spray. Never use grease or silicone spray.
l It is suggested that while at the site voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the operator
is within ten percent of the operator’s rating.
X
X
X
X
35
MAINTENANCE
Batteries
Batteries will degrade over time depending on temperature and usage. The operator alarm will beep 3 times with a command if the battery is low. Batteries
do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part
29-NP712 for replacement batteries. The batteries contain lead and need to be disposed of properly.
The operator comes with two 7AH batteries. Two 33AH batteries (A12330SGLPK), with Solar Harness Kit (K94-37236) may be used in place of the 7AH
batteries.
Drive Train
Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust either of the two chain eye bolts. NOTE:
The chain should have no more than 1 inch of sag for every 10 feet of chain length.
36
TROUBLESHOOTING
To protect against fire and electrocution:
l DISCONNECT power (AC or solar and battery) BEFORE installing or
servicing operator.
For continued protection against fire:
l Replace ONLY with fuse of same type and rating.
Diagnostic Codes
NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.
To View the Codes
The codes will show on the diagnostic display.
The operator will show the code sequence number followed by the code
number:
To Scroll Through the Saved Codes
The operator will only keep track of up to 20 codes, then will start saving
over the oldest codes as new codes occur.
To Exit
Press and release the STOP button to exit. The display will also time out
after two minutes of inactivity.
To Reset the Code History
1. Press and hold the STOP button for six seconds. The display will
show "Er" then "CL" alternately for six seconds.
2. Release the STOP button. The code history has now been reset and the
display will show "- -" until a new code occurs.
3. Press and release the STOP button to exit.
37
TROUBLESHOOTING
Diagnostic Codes Table
Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.
LiftMaster SystemInstalled SystemInformational
CodeMeaningSolutionSaved
31
Main control board has experienced an internal
failure.
34
Absolute Position Encoder Error, not getting
position information from encoder
35
Max-Run-Time Exceeded ErrorCheck for an obstruction, then reprogram the limits.YES
36
Product ID ErrorWas the control board just replaced? If so, erase limits, enter limit setup
37
Product ID FailureUnplug product ID harness then plug back in. Disconnect all power, wait
38
Hard Stop Limit (Arm 1)Limit may be set too tightly against a non-resilient hard stop (re-adjust
40
Battery overvoltageToo much voltage on the battery. Check harness. Make sure there is NOT a
41
Battery overcurrentPossible short of the battery charge harness. Check harness. Make sure
42
No battery at boot upCheck battery connections and installation. Replace batteries if depleted to
43
Exit Loop ErrorFailure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop
44
Shadow Loop Error
45
Interrupt Loop Error
46
Wireless edge battery lowReplace batteries in wireless edge.YES
50
Run-Distance ErrorThe limits are less than the minimum requirement or longer than what
Brownout occurred
53
Wireless Second Operator Communication Error
54
Minimum number of monitored entrapment
60
protection devices not installed.
CLOSE EYE/INTERRUPT held more than 3 minutes
61
CLOSE EDGE held more than 3 minutes
62
OPEN EYE/EDGE held more than 3 minutes
63
CLOSE EYE/INTERRUPT held more than 3 minutes
64
CLOSE EYE/EDGE held more than 3 minutes
65
OPEN EYE/EDGE held more than 3 minutes
66
Wireless edge triggered more than 3 minutesCheck wired input for wiring issue or obstruction.YES
67
Wireless edge loss of monitoringCheck wireless edge inputs.YES
68
Disconnect all power, wait 15 seconds, then reconnect power (reboot). If
issue continues, replace main control board.
Check APE assembly and wiring connections. Replace the APE assembly
if necessary.
mode and set limits. If not, disconnect all power, wait 15 seconds, then
reconnect power before changing product ID harness.
15 seconds, then reconnect power before replacing product ID harness.
limit). Operator may be at end of travel (re-adjust mounting).
24V battery on a 12V system.
you do NOT have a 12V battery on a 24V system.
less than 20V on a 24V system or less than 10V on a 12V system. Make
sure there is NOT a single 12V battery on a 24V system.
Detector only) Check loop wiring throughout connection. May be a short
in the loop, or an open connection in the loop.
was learned. Check limit positions and proper switch function. Rundistance can be re-learned by setting the handing again.
AC/DC board supply dipped below allowable level. Review power supply
and wiring. If rebooting, ensure enough time for discharge of power to
force a fresh boot.
Check the second operator for power. If OFF, restore power and try to run
the system. If powered, deactivate the wireless feature and then re-learn
the second operator.
Review monitored entrapment protection device connections. Slide gate
operators require a minimum of two external safety devices; one in the
close and one in the open direction.
Check wired input on main control board; check for alignment or
obstruction.
Check wired input on expansion board; check for alignment or
obstruction.
External Entrapment
Protection
Inherent Entrapment
Protection
NO
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
38
TROUBLESHOOTING
CodeMeaningSolutionSaved
Wireless edge triggered
69
CLOSE EYE/INTERRUPT triggered, causing
70
reversal, preventing close, or resetting TTC
CLOSE EDGE triggered, causing reversal, NO
71
preventing close, or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
72
preventing opening
CLOSE EYE/INTERRUPT triggered, causing
73
reversal, preventing close, or resetting TTC
CLOSE EYE/EDGE triggered, causing reversal and
74
preventing close or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
75
preventing opening
Close input (EYE/EDGE) communication fault from
80
other operator
Open input (EYE/EDGE) communication fault from
81
other operator
Close input (EYE/EDGE) communication fault
82
(expansion board)
Open input (EYE/EDGE) communication fault
83
(expansion board)
Non-monitored device detected on the wireless
84
safety system
Force Reversal (Operator 1)
91
RPM / STALL Reversal (Operator 1)
93
99Normal OperationNo action requiredYES
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check inputs and wiring.
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on main control board
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on expansion board.
Check inputs and communication method between operators, either wired
bus or radio. Ensure operator is powered. May have to erase the wireless
communication and reprogram the two operators.
Check the connections between the main board and the expansion board.YES
Non-monitored contact closure devices are not supported. Make sure
connected devices are monitored. Check edges for proper orientation and
resistive end cap connection.
Check for obstruction. If no obstruction, check that the mechanical
assembly is engaged and free to move. See section on Limit and Force
Adjustment, and Obstruction Test.
Check for obstruction. If no obstruction, check the operator wiring and
that the mechanical assembly is engaged and free to move. Replace APE
assembly.
NO
NO
NO
YES
YES
YES
YES
39
Control Board LEDs
TROUBLESHOOTING
INPUT
POWER
BATT
CHARGING
TIMER
GATE
MOVING
BATT LOW
ACC PWR
OVLD
STATUS LEDS
OFFOFF state
ONAC charger or Solar power
available
OFFNot charging
ONThree stage battery charging
OFFThe timer is disabled
ONThe timer is enabled
MEDIUM BLINK (1
blink per second)
FAST BLINK (2
blinks per second)
FASTEST BLINK (8
blinks per second)
OFFThe gate is stopped
ONThe gate is opening or closing
MEDIUM BLINK (1
blink per second)
FASTEST BLINK (8
blinks per second)
OFFNo battery error
ONBattery low
MEDIUM BLINK (1
blink per second)
OFFAccessory power is okay
ONAccessory overload protector
The timer is running
The timer is paused
The timer is canceled
Operator is in E1 (single
entrapment)
The operator is in E2 (double
entrapment)
Battery critically low
opened
OPEN, CLOSE,
STOP INPUT
FIRE DEPT INPUT
EXIT
SHADOW
CLOSE
EYES/INTERRUPT
CLOSE EDGE
OPEN EYES/EDGE
LOCK
INPUT LEDS
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFInput inactive
ONInput active
BLINKInput active on other operator
OFFMaglock relay inactive
ONMaglock relay active
40
TROUBLESHOOTING
Troubleshooting Chart
SYMPTOMPOSSIBLE CAUSESSOLUTIONS
Operator does not
run and diagnostic
display not on.
Control board
powers up, but
motor does not
run.
Gate moves, but
cannot set correct
limits.
Gate does not fully
open or fully close
when setting
limits.
Operator does not
respond to a wired
control/command
(example: Open,
Close, SBC, etc.)
Operator does not
respond to a
wireless control or
transmitter
Gate stops during
travel and reverses
immediately.
a. No power to control board
b. Open fuse
c. If on battery power only, low or dead
batteries
d. Defective control board
a. Reset switch is stuck
b. Stop button active or jumper not in place
for stop circuit
c. If on battery power only, low or dead
batteries
d. Open or Close input active
e. Entrapment Protection Device active
f. Vehicle loop detector or probe active
g. Defective control board
a. Gate does not move to a limit position
b. Gate is too difficult to move
c. Limits are set too close (slide gate
applications only)
a. Gate does not move to a limit position
b. Gate is too difficult to move
a. Check Open and Close command input
LEDs
b. Stop button is active
c. Reset button is stuck
d. If on battery power only, low or dead
batteries
e. Entrapment Protection Device active
f. Vehicle loop detector or vehicle probe
active
a. Check XMITTER LED when wireless
control is active
b. Stop button is active
c. Reset button is stuck
d. Poor radio reception
a. Control (Open, Close) becoming active
b. Vehicle loop detector active
c. Low battery voltage
a. Check AC and battery power
b. Check fuses
c. Charge batteries by AC or solar power or replace batteries
d. Replace defective control board
a. Check reset switch
b. Check Stop button is not “stuck on”, or verify that the stop button is a
normally closed circuit, or put a jumper on the stop circuit.
c. Charges batteries by AC or solar power or replace batteries
d. Check all Open and Close inputs for a “stuck on” input
e. Check all Entrapment Protection Device inputs for a “stuck on” sensor
f. Check all vehicle detector inputs for a “stuck on” detector
g. Replace defective control board
a. Use manual disconnect, manually move gate, and ensure gate moves
easily limit to limit. Repair gate as needed.
b. Gate must move easily and freely through its entire range, limit to limit.
Repair gate as needed.
c. Ensure the gate moves at least four feet between the OPEN limit and the
CLOSE limit.
a. Use manual disconnect, manually move gate, and ensure gate moves
easily limit to limit. Repair gate as needed.
b. Gate must move easily and freely through its entire range, limit to limit.
Repair gate as needed.
a. Check all Open and Close inputs for a “stuck on” input
b. Check Stop button is not “stuck on”
c. Check Reset button
d. Charges batteries by AC or solar power or replace batteries
e. Check all Entrapment Protection Device inputs for a “stuck on” sensor
f. Check all vehicle detector inputs for a “stuck on” detector
a. Activate wireless control and check XMITTER LED is on. Re-learn
wireless control/transmitter to control board. Replace wireless control as
needed.
b. Check Stop button is not “stuck on”
c. Check Reset button
d. Check if similar wired control operates correctly. Check if wireless
controls works properly when within a few feet of operator. Check
operator’s antenna and antenna wire. Check other wireless controls or
devices.
a. Check all Open and Close inputs for an active input
b. Check all vehicle detector inputs for an active detector
c. Battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or
solar power or replace batteries
41
TROUBLESHOOTING
SYMPTOMPOSSIBLE CAUSESSOLUTIONS
Gate opens, but
will not close with
transmitter or
Timer-to-Close.
Gate closes, but
will not open.
Exit loop activation
does not cause
gate to open.
Interrupt loop does
not cause gate to
stop and reverse.
Shadow loop does
not keep gate at
open limit.
Obstruction in
gate's path does
not cause gate to
stop and reverse.
Photoelectric
sensor does not
stop or reverse
gate.
Edge Sensor does
not stop or reverse
gate.
Alarm sounds for 5
minutes or alarm
sounds with a
command.
Alarm beeps three
times with a
command.
On dual-gate
system, incorrect
gate opens first or
closes first.
Alarm beeps when
running.
a. Open control active
b. Vehicle loop detector active
c. Loss of AC power with AC FAIL set to
OPEN
d. Low battery with LOW BATT set to OPEN
e. Fire Dept input active
f. Timer-to-Close not set
g. Close Entrapment Protection Device active
a. Vehicle loop detector active
b. Low battery with LOW BATT option set to
CLOSE
a. Exit vehicle detector setup incorrectly
b. Defective Exit loop detector
c. Low battery with LOW BATT option set to
CLOSE
a. Vehicle detector setup incorrectly
b. Defective vehicle loop detector
c. Anti-tail set to ON
a. Vehicle detector setup incorrectly
b. Defective vehicle loop detector
a. Force adjustment neededa. Refer to the Adjustment section to conduct the obstruction test and
a. Incorrect photoelectric sensor wiring
b. Defective photoelectric sensor
a. Incorrect edge sensor wiring
b. Defective edge sensor
a. Double entrapment occurred (two
obstructions within a single activation)
a. Low batterya. Check if AC power is available. If no AC power, then running on
a. Incorrect Bipart switch settinga. Change setting of both operator’s Bipart switch settings. One operator
a. Expansion board setting
b. Constant pressure to open or close is given
a. Check all Open inputs for an active input
b. Check all vehicle detector inputs for an active detector
c. Check AC power and AC Fail option setting
d. Check if AC power is available. If no AC power, then running on
batteries and battery voltage must be 23.0 Vdc or higher. Charge
batteries by AC or solar power or replace batteries.
e. Check Fire Dept input
f. Check Timer-to-Close (TTC) setting
g. Check all Entrapment Protection Device inputs for an active sensor
a. Check all vehicle detector inputs for an active detector
b. Check if AC power is available. If no AC power, then running on
batteries and battery voltage must be 23.0 Vdc or higher. Charge
batteries by AC or solar power or replace batteries.
a. Review Exit loop detector settings. Adjust settings as needed.
b. Replace defective Exit loop detector.
c. Check if AC power is available. If no AC power, then running on
batteries and battery voltage must be 23.0 Vdc or higher. Charge
batteries by AC or solar power or replace batteries.
a. Review Interrupt loop detector settings. Adjust settings as needed.
b. Replace defective Interrupt loop detector.
c. Set anti-tail to OFF.
a. Review Shadow loop detector settings. Adjust settings as needed.
b. Replace defective Shadow loop detector.
perform the proper force adjustment that is needed.
a. Check photoelectric sensor wiring. Retest that obstructing photoelectric
sensor causes moving gate to stop, and may reverse direction.
b. Replace defective photoelectric sensor. Retest that obstructing
photoelectric sensor causes moving gate to stop, and may reverse
direction.
a. Check edge sensor wiring. Retest that activating edge sensor causes
moving gate to stop and reverse direction.
b. Replace defective edge sensor. Retest that activating edge sensor causes
moving gate to stop and reverse direction.
a. Check for cause of entrapment (obstruction) detection and correct. Press
the reset button to shut off alarm and reset the operator.
batteries and battery voltage must be 23.0 Vdc or higher. Charge
batteries by AC or solar power or replace batteries
should have Bipart switch ON (operator that opens second) and the other
operator should have Bipart switch OFF (operator that opens first).
a. Pre-warning is set to "ON"
b. Constant pressure to open or closed is given
42
TROUBLESHOOTING
SYMPTOMPOSSIBLE CAUSESSOLUTIONS
Expansion board
function not
controlling gate.
Maglock not
working correctly.
Solenoid lock not
working correctly.
Switched (SW)
Accessory power
remaining on.
Accessories
connected to
Switch (SW)
Accessory power
not working
correctly, turning
off, or resetting.
Accessories
connected to
Accessory power
not working
correctly, turning
off, or resetting.
Quick Close not
working correctly.
Anti-Tailgating not
working correctly.
AUX Relay not
working correctly.
Solar operator not
getting enough
cycles per day.
Solar operator,
insufficient standby
time.
a. Defective main board to expansionboard
wiring
b. Incorrect input wiring to expansion board
c. Defective expansion board or defective
main board
a. Maglock wired incorrectlya. Check that Maglock is wired to N.C. and COM terminals. Check that
a. Solenoid wired incorrectlya. Check that Solenoid is wired to N.O. and COM terminals. Check that
a. In limit setup modea. Learn the limits
a. Normal behaviora. Move accessory to accessory power "ON"
a. Accessory power protector active
b. Defective control board
a. Quick Close setting incorrect
b. Interrupt loop detector
c. Defective Expansion board
a. Anti-Tail setting incorrect
b. Interrupt loop detector
c. Defective Expansion board
a. AUX Relay setting incorrect
b. AUX Relay wiring incorrect
c. Defective Expansion board
a. Insufficient panel wattage
b. Excessive accessory power draw
c. Old batteries
d. Solar panels are not getting enough
sunlight
a. Insufficient panel wattage
b. Excessive accessory power draw
c. Battery capacity too low
a. Check main board to expansion board wiring. If required, replace wire
cable.
b. Check wiring to all inputs on expansion board.
c. Replace defective expansion board or defective main board
Maglock has power (do not power maglock from control board
accessory power terminals). If shorting lock’s NO and COM wires does
not activate Maglock, then replace Maglock or Maglock wiring (refer to
Wiring Diagrams).
Solenoid has power (do not power solenoid from control board
accessory power terminals). If shorting lock’s NC and COM wires does
not activate Solenoid, then replace Solenoid lock or Solenoid wiring
(refer to Wiring Diagrams).
a. Disconnect all accessory powered devices and measure accessory power
voltage (should be 23 – 30 Vdc). If voltage is correct, connect
accessories one at a time, measuring accessory voltage after every new
connection.
b. Replace defective control board
a. Check that Quick Close setting is ON
b. Check operation of Interrupt Loop detector
c. Replace defective Expansion board
a. Check that Anti-Tail setting is ON
b. Check operation of Interrupt Loop detector
c. Replace defective Expansion board
a. Check AUX Relay switches settings
b. Check that wiring is connected to either N.O. and COM or to N.C. and
COM.
c. Set AUX Relay to another setting and test. Replace defective expansion
board.
a. Add more solar panels
b. Reduce the accessory power draw by using LiftMaster low power
accessories
c. Replace batteries
d. Relocate the solar panels away from obstructions (trees, buildings, etc.)
a. Add more solar panels
b. Reduce the accessory power draw by using LiftMaster low power
accessories
c. Use batteries with higher amp hour (AH) rating
43
Step 6 Solar Panel(s)
SOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES
APPENDIX
Solar Application Requirements
l A minimum of two 10W solar panels in series (Model SP10W12V).
l A maximum of six 10W solar panels (Model SP10W12V).
l Solar Harness Kit (Model K94-37236).
l A heater cannot be used with a solar application.
Solar Zones
Solar panel recommendations are based upon the average solar radiation
and the temperature effects on batteries in the given zones as shown on the
map below. Local geography and weather conditions may require
additional solar panels. Solar powered gate operator installations are not
supported in northern climates due to cold weather and a reduced number
of hours of sunlight during the winter months. The cycles/day ratings are
approximations. Ratings vary based on gate construction, installation, and
temperature. Solar panels cannot be installed in areas that experience long
periods of heavy fog, lake effect snow, or rain.
44
APPENDIX
Solar usage guide
Typical System Standby Battery Current Consumption (mA)
System voltage24V
Main board with no radios programmed2.7 mA
One or more LiftMaster®remote controls programmed+1 mA
MyQ®device or wireless dual gate programmed+2.4 mA
Expansion board+11.1 mA
Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board)+3.8 mA
Add up current draw by feature and accessory to determine total current draw
NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications.
The location of the panel(s) is critical to the success of the installation. In
general, the panel(s) should be mounted using the provided angle bracket
facing due south. The solar panel(s) should be mounted in an area clear of
all obstructions and shade from buildings and trees. If the panel(s) is not
casting a shadow, the battery is not being charged.
NOTE: Tall trees or buildings that do not shade the solar panel(s) in the
summer could shade the solar panel(s) during the winter months when the
sun sits lower in the sky.
Solar panel(s) MUST be installed facing south. Use a compass to determine direction. Below are general instructions for installing the solar panel(s). Your
installation may vary slightly depending on the solar panel purchased.
1. Position the mounting bracket on the mounting surface. Mark and drill holes.
2. Secure the solar panel to the mounting bracket using the hex bolts, hex nuts and washers provided.
3. Secure the solar panel to the mounting surface using lag screws provided.
46
Wire the Batteries
Solar panel applications require the Solar
Harness Kit model K94-37236, see Accessories.
APPENDIX
Wire the solar panels
Proceed to the Dual Gate section (if applicable) or proceed to the Adjustment section.
47
APPENDIX
SAMS wiring with relays not energized
Dual Gate Settings
NOTE: We recommend that all accessories and board configurations are set on the primary operator.
Main control board
FEATUREPRIMARY OPERATORSECONDARY OPERATOR
Timer-toClose
Bi-Part
Delay
Switch
Set the TTC dial to desired
setting
Bi-Part Delay: ON (will open
last and close first)
Tandem Mode: OFF
Synchronized Close: ON
OFF
Bi-Part Delay: OFF (will open
first and close last)
Tandem Mode: OFF
Synchronized Close: ON
Expansion board
FEATUREPRIMARY OPERATOR
QUICK CLOSE Switch ONOFF
ANTI-TAIL SwitchONOFF
LOW BATT SwitchBattery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
AC FAIL OPEN/BATT
Switch
OPENOPEN
SECONDARY
OPERATOR
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
Accessories
ACCESSORYPRIMARY OPERATOR
Remote ControlsProgram remote
LiftMaster Internet
Gateway
Garage and Gate
Monitor
controls 1 to 50 to the
primary operator.
Program to primary
operator.
Program to primary
operator.
SECONDARY
OPERATOR
Program remote
controls 51 to 100 to the
secondary operator
48
APPENDIX
Limit Setup with a Remote Control
To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the
Programming section.
Initial Limits and Force Adjustment
For dual gate applications the limits will have to be set for each
operator. The gate MUST be attached to the operator before setting
the limits and force.
Ensure the gate is closed.
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter limit setting mode.
2. Press and hold the OPEN or CLOSE button on the remote control
until the gate reaches the desired open position. The gate can be
jogged back and forth using the OPEN and CLOSE buttons on the
remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
4. Press and release the OPEN button on the remote control again to
set the open limit.
5. Press and hold the CLOSE or OPEN button on the remote control
until the gate reaches the desired close position. The gate can be
jogged back and forth using the OPEN and CLOSE buttons on the
remote control.
6. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
7. Press and release the CLOSE button on the remote control again to
set the close limit.
8. Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit
setting mode.
Refer to the Adjustment section and follow the instructions for Fine Tunethe Force and Obstruction Test . Perform the "Obstruction Test" after every
limit and force setting adjustment.
Adjust the limits
If the limits have already been set the operator will exit the limit setting
mode after resetting each limit.
Set the Close Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter limit setting mode.
2. Press and hold the CLOSE button on the remote control until the gate
reaches the desired close position. The gate can be jogged back and
forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
4. Press and release the CLOSE button on the remote control again to set
the close limit.
When the close limit is set properly the operator will automatically exit limit
setting mode.
Set the Open Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter limit setting mode.
2. Press and hold the OPEN button on the remote control until the gate
reaches the desired open position. The gate can be jogged back and
forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
4. Press and release the OPEN button on the remote control again to set
the open limit.
When the open limit is set properly the operator will automatically exit limit
setting mode.
49
WIRING DIAGRAM
To protect against fire and electrocution:
l DISCONNECT power (AC or solar and battery) BEFORE installing or
servicing operator.
For continued protection against fire:
l Replace ONLY with fuse of same type and rating.
50
REPAIR PARTS
51
ACCESSORIES
Entrapment Protection
LiftMaster monitored through beam
photoelectric sensor
LiftMaster monitored wireless edge kit
(transmitter and receiver)
Model LMWEKITU
LiftMaster monitored wireless edge transmitter
Model LMWETXU
Large profile monitored edge (82 ft. roll)
Model L50
Large profile ends kit (10 pair)
Model L50E
Small profile monitored edge (82 ft. roll)
Model S50
Small profile ends kit (10 pair)
Model S50E
Remote Controls
LiftMaster offers a variety of LiftMaster remote controls to satisfy your
application needs. Single-button to 4-button, visor or key chain. The
following remote controls are compatible with operators manufactured by
LiftMaster after 1993. Contact your authorized LiftMaster dealer for additional
details and options.
3-button remote control
The 3-button remote control can be programmed to
control the operator. Includes visor clip.
Model 893MAX
3-button mini-remote control
The 3-button remote control can be programmed to
control the operator. Includes key ring and fastening
strip.
Model 890MAX
Security+ 2.0®learning remote controls
One button can control a gate operator and the other
(s) can control garage door(s). It can also be
programmed to Security+®or Security+ 2.0®code
format.
Models 892LT and 894LT
Universal single and 3-button remote controls
Ideal for applications requiring a large number of
remote controls.
Models 811LM and 813LM
Keyless entry
Enables homeowner to operate gate operator from
outside by entering a 4-digit code on a specially
designed keypad.
Model 877MAX
Plastic channel
8 ft. (2.4 m) for both small and large profile edges (pack of 10).
Model L50CHP
Aluminum channel
10 ft. (3.1 m) for both small and large edge profiles (pack of 8).
Model L50CHAL
LiftMaster large profile monitored edges (4ft.,5ft., 6ft.)
Durable wireless keypad with blue LED backlight
metal keypad, zinc-alloy metal front cover and 5
year 9V lithium battery. Security+ 2.0®compatible.
Model KPW250
Commercial access control receiver
Access control receiver for up to 1,000 devices (any
combination of remote controls and wireless
keyless entries).
Model STAR1000
52
ACCESSORIES
Miscellaneous
Post-mounting plate
For post-mounting models CSL24UL,
CSW24UL CSW200UL and SL3000UL
commercial gate operators. Posts not
included.
Model MPEL
Remote antenna extension kit
The remote antenna extension kit allows the
antenna to be remotely installed.
Model 86LM
Plug-in loop detector
Low power. Conveniently plugs into
existing control board.
Model LOOPDETLM
Loop Detector
Low power loop detectors mounted and
wired separately inside control box.
LiftMaster low power accessory.
Model LD7LP
Vehicle sensing probe
The vehicle sensing probe is buried in the
ground and can detect a car as it
approaches and will then open the gate.
Model CP3
Solar panel kit
This kit is to replace or add a solar panel to
the operator application. 60W maximum for
24 Vdc operators and 30W maximum for
12 Vdc operators. Requires a 33AH battery
harness.
Models SP10W12V (10 Watt, 12V) and
SP20W12V (20 Watt, 12V)
Magnetic gate lock
Outdoor magnetic lock, transformer,
junction box, mounting plate and hardware.
Not for use with Solar Applications. Must
be powered separately.
Model MG1300
Heater
The heater keeps the gearbox and batteries
at a suitable temperature when the outside
temperature is below -4°F (-20°C). The
thermostat MUST be set between 45°F and
60°F (7°C and 15.5°C) to ensure proper
gate operation. The heater can be powered
by 110 to 250 Vac.
Model HTR
LiftMaster®internet gateway
Internet enabled accessory which connects to the
computer and allows you to monitor and control
gate operators and lighting accessories enabled by
MyQ®technology.
Changes input voltage (208/240/480/575 Vac) to an
output voltage of 120 Vac. Rated 208/240/480/575
Vac, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH
Model 3PHCONV
Solenoid lock harness kit
Model K77-37972
Batteries
Gate access system batteries replace or upgrade the gate operator batteries.
Two identical 12 Vdc batteries are required for each gate operator. Do not
mix 7AH and 33AH batteries within a gate operator.
7AH batteries
Standard 7 AMP-Hour Battery, 12 Vdc, to replace
original batteries provided with operator. Reuse
existing harnesses.
Models 29-NP712 (1) and K74-30762 (2)
33AH batteries
Upgrade 33 AMP-Hour Battery, 12 Vdc. Ideal for
solar applications and extended battery backup. Two
required.
Model A12330SGLPK
Battery tray
Two required for 33AH applications.
Model K10-34758-2
Universal solar wire harness kit
For 7AH and 33AH applications.
Model K94-37236
53
WARRANTY
LiftMaster 7 year residential / 5 year commercial Limited Warranty
LiftMaster (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in
materials and/or workmanship for a period of 7 year residential / 5 year commercial from the date of purchase [and that the CSL24UL is free from defect in
materials and/or workmanship for a period of 7 year residential / 5 year commercial from the date of purchase]. The proper operation of this product is
dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those
instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before
dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping
instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty
repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will
be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factoryrebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE 7 YEAR RESIDENTIAL / 5 YEAR COMMERCIAL LIMITED WARRANTY PERIOD SET
FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE CSL24UL, WHICH ARE LIMITED IN DURATION TO THE 7 YEAR
RESIDENTIAL / 5 YEAR COMMERCIAL LIMITED WARRANTY PERIOD FOR THE CSL24UL, AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY
AFTER SUCH PERIOD. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS
LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE
(INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED
REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, OR REPLACEMENT OF
BATTERIES.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GATE OR GATE HARDWARE, INCLUDING BUT NOT
LIMITED TO THE GATE SPRINGS, GATE ROLLERS, GATE ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY
PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS
COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH
USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT,
NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY
OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to
you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.