Lift-master CPS User Manual

1
Commercial Protector System
®
OWNER’S MANUAL
For use with Models CPS, CPSIII-01 and CPS-L
Install the Protector System
®
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR
Be sure power to the operator is disconnected.
When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye transmits an invisible light beam to the receiving eye. If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position.
The units must be installed inside the garage so that the sending (emitting) and receiving eyes face each other across the door, no more than 6" (15 cm) above the floor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens.
The brackets must be securely fastened to a solid surface such as the wall framing. If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing. If it does, use a piece of wood to build out each sensor mounting location to the minimum depth required for light beam clearance.
Facing the door from inside the garage (installation procedures are the same for all door types).
This device is for use ONLY on LiftMaster Commercial Door Operators. Use on other than recommended equipment voids warranty, and may cause property damage or SERIOUS personal INJURY. Read and follow ALL instructions.
Have door in full open or closed position and DISCONNECT power to the operator BEFORE installing the Commercial Protector System®.
WARNING
WARNING
Part # Description QTY
12B483 “C” Wrap Brackets 2 12B485 Slotted Bracket 2
12B484 Square Hole Bracket 2 41A4116 Safety Sensor Hardware 1 41K4654 Safety Sensor Kit
(receiving and sending eyes)
1
1A6078 Option Board (CPSIII ONLY) 1
41K4629 Commercial Protector Interface (CPS ONLY) 1
—Left Side of Garage—
Safety Reversing Sensor
Invisible Light Beam Protection Area
— Right Side of Garage
Safety Reversing Sensor
2
INSTALLING THE BRACKETS
Figures 1, 2 and 3 show recommended assembly of the bracket(s) and “C” wrap based on the wall installation of the sensors on each side of the door as shown on page 1 or on the door tracks themselves.
Figures 4 and 5 are variations which may fit your installation requirements better. Make sure the wraps and brackets are
aligned so the sensors will face each other across the door.
WALL OR DOOR TRACK INSTALLATION
• Fasten the “C” wraps to the mounting brackets having square holes, using hardware shown in Figure 1.
WALL INSTALLATION
• Connect each assembly to a slotted bracket, using the hardware shown (Figure 2).
• Finger tighten the lock nuts.
• Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, no higher than 6" above the floor.
• Attach brackets to wall with lag screws as shown in Figure 2.
• Adjust right and left side bracket assemblies to the same distance out from mounting surface. Make sure all door hardware obstructions are cleared. Tighten the nuts securely.
DOOR TRACK INSTALLATION
• Discard slotted bracket. Drill 3/8" holes in each track and fasten securely with hardware as shown in Figure 3.
HARDWARE SHOWN ACTUAL SIZE
INSTALLATION FOR LIFTMASTER COMMERCIAL OPERATORS
Figure 1 WALL or DOOR Track Installation
Mounting Bracket With Square Holes
#10-32 Lock Nuts
“C” Wrap
#10-32x3/8" Screws
Figure 2 WALL Installation
Inside Wall
1/4x1-1/2" Lag Screws
Mounting Bracket with Slot
1/4"-20 Lock Nuts
1/4-20x1/2" Carriage Bolts (with square shoulder)
“C” Wrap
Mounting Bracket with Square Holes
Figure 3 DOOR Track Installation
Inside Wall
Door Track
1/4" Lock Nuts
Mounting Bracket with Square Holes
Figure 4 Alternate Wall Mount
Inside Wall
Floor
Mounting Bracket with Slot
Mounting Bracket with Square Holes
Indicator Light
“C” Wrap
Sensor with wire
Drill 3/8" Holes
1/4-20x1/2" Carriage Bolts
Figure 5 Alternate Floor Mount
Inside Wall
“C” Wrap
Floor
Sensor with wire
Indicator Light
Mounting Bracket with Square Holes
Mounting Bracket with Slot
Attach with concrete anchors (not provided)
“C” Shaped Wrap
Screw #10-32x3/8"
Lock Nut #10x32
Lag Screw 1/4x1-1/2"
Staples
Carriage Bolts 1/4"-20x1/2"
Lock Nut 1/4"-20
3
HARDWARE SHOWN ACTUAL SIZE
Mounting and Wiring the Safety Sensors
• Insert the wire connector into each sensor and push until you hear a click. The white tab on the sensor should be flush with the back of connector.
• Center each sensor unit in a “C” wrap with lenses pointing toward each other across the door (Figure 6).
• Secure sensors with hardware as shown. Finger tighten the wing nut on the receiving eye to allow for final adjustment. Securely tighten the sending eye wing nut.
• Run paired wires from both sensors to the operator (Figure 6). Use insulated staples to secure the wire to the wall and ceiling.
• For wiring connections, see following pages:
CPS page 4 CPS-L page 4 CPSIII-01 page 5
Aligning the Safety Sensors
• Power up the operator. Green indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.
If the receiving eye indicator light is not glowing steadily (and the invisible light beam path is not obstructed), alignment is required.
Figure 6
• Loosen the receiving eye wing nut to allow slight rotation of unit. Adjust sensor vertically and/or horizontally until the green indicator light glows steadily.
• When indicator lights are glowing steadily in both units, tighten the wing nut in the receiving eye unit.
WIRING FOR LIFTMASTER COMMERCIAL OPERATORS
1/4-20x1-1/2" Hex Bolt Wing Nut
Wing Nut
“C” Wrap
Sensor
Wire
Indicator Light
1/4-20 x 1-1/2"
Hex Bolt
Bell Wire
Secure Wire with Insulated Staples
Connect Wire to Commercial Protector Interface
Sensor Beam 6" (15 cm) max. above floor
Sensor Beam 6" (15 cm) max. above floor
Invisible Light Beam Protection Area