Commercial Protector System
®
OWNER’S MANUAL
For use with Models CPS, CPSIII-01 and CPS-L
Install the Protector System
®
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING
SENSOR
Be sure power to the operator is disconnected.
When properly connected and aligned, the sensor will detect an
obstacle in the path of its electronic beam. The sending eye
transmits an invisible light beam to the receiving eye. If an
obstruction breaks the light beam while the door is closing, the
door will stop and reverse to full open position.
The units must be installed inside the garage so that the
sending (emitting) and receiving eyes face each other across the
door, no more than 6" (15 cm) above the floor. Either can be
installed on the left or right of the door as long as the sun never
shines directly into the receiving eye lens.
The brackets must be securely fastened to a solid surface such
as the wall framing. If installing in masonry construction, add a
piece of wood at each location to avoid drilling extra holes in
masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of
the garage door (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door is closing. If it
does, use a piece of wood to build out each sensor mounting
location to the minimum depth required for light beam
clearance.
Facing the door from inside the garage (installation procedures are the same for all door types).
This device is for use ONLY on LiftMaster Commercial Door
Operators. Use on other than recommended equipment voids
warranty, and may cause property damage or SERIOUS
personal INJURY. Read and follow ALL instructions.
Have door in full open or closed position and DISCONNECT
power to the operator BEFORE installing the Commercial
Protector System®.
Part # Description QTY
12B483 “C” Wrap Brackets 2
12B485 Slotted Bracket 2
12B484 Square Hole Bracket 2
41A4116 Safety Sensor Hardware 1
41K4654 Safety Sensor Kit
(receiving and sending eyes)
1
1A6078 Option Board (CPSIII ONLY) 1
41K4629 Commercial Protector Interface (CPS ONLY) 1
—Left Side of Garage—
Safety Reversing
Sensor
Invisible Light
Beam Protection
Area
— Right Side of Garage
Safety Reversing
Sensor
2
INSTALLING THE BRACKETS
Figures 1, 2 and 3 show recommended assembly of the
bracket(s) and “C” wrap based on the wall installation of the
sensors on each side of the door as shown on page 1 or on the
door tracks themselves.
Figures 4 and 5 are variations which may fit your installation
requirements better. Make sure the wraps and brackets are
aligned so the sensors will face each other across the door.
WALL OR DOOR TRACK INSTALLATION
• Fasten the “C” wraps to the mounting brackets having square
holes, using hardware shown in Figure 1.
WALL INSTALLATION
• Connect each assembly to a slotted bracket, using the
hardware shown (Figure 2).
• Finger tighten the lock nuts.
• Use bracket mounting holes as a template to locate and drill
(2) 3/16" diameter pilot holes on the wall at each side of the
door, no higher than 6" above the floor.
• Attach brackets to wall with lag screws as shown in Figure 2.
• Adjust right and left side bracket assemblies to the same
distance out from mounting surface. Make sure all door
hardware obstructions are cleared. Tighten the nuts securely.
DOOR TRACK INSTALLATION
• Discard slotted bracket. Drill 3/8" holes in each track and
fasten securely with hardware as shown in Figure 3.
HARDWARE SHOWN ACTUAL SIZE
INSTALLATION FOR LIFTMASTER COMMERCIAL OPERATORS
Figure 1 WALL or DOOR Track Installation
Mounting Bracket
With Square Holes
#10-32
Lock Nuts
“C” Wrap
#10-32x3/8"
Screws
Figure 2 WALL Installation
Inside
Wall
1/4x1-1/2"
Lag Screws
Mounting Bracket
with Slot
1/4"-20
Lock Nuts
1/4-20x1/2" Carriage Bolts
(with square shoulder)
“C” Wrap
Mounting Bracket
with Square Holes
Figure 3 DOOR Track Installation
Inside
Wall
Door Track
1/4" Lock Nuts
Mounting Bracket
with Square Holes
Figure 4 Alternate Wall Mount
Inside
Wall
Floor
Mounting Bracket
with Slot
Mounting Bracket
with Square Holes
Indicator Light
“C” Wrap
Sensor
with wire
Drill 3/8"
Holes
1/4-20x1/2"
Carriage Bolts
Figure 5 Alternate Floor Mount
Inside
Wall
“C” Wrap
Floor
Sensor with wire
Indicator Light
Mounting Bracket
with Square Holes
Mounting Bracket
with Slot
Attach with
concrete
anchors
(not provided)
“C” Shaped
Wrap
Screw
#10-32x3/8"
Lock Nut
#10x32
Lag Screw 1/4x1-1/2"
Staples
Carriage Bolts
1/4"-20x1/2"
Lock Nut
1/4"-20
HARDWARE SHOWN ACTUAL SIZE
Mounting and Wiring the Safety Sensors
• Insert the wire connector into each sensor and push until you
hear a click. The white tab on the sensor should be flush with
the back of connector.
• Center each sensor unit in a “C” wrap with lenses pointing
toward each other across the door (Figure 6).
• Secure sensors with hardware as shown. Finger tighten the
wing nut on the receiving eye to allow for final adjustment.
Securely tighten the sending eye wing nut.
• Run paired wires from both sensors to the operator
(Figure 6). Use insulated staples to secure the wire to the wall
and ceiling.
• For wiring connections, see following pages:
CPS page 4
CPS-L page 4
CPSIII-01 page 5
Aligning the Safety Sensors
• Power up the operator. Green indicator lights in both the
sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.
If the receiving eye indicator light is not glowing steadily (and
the invisible light beam path is not obstructed), alignment is
required.
Figure 6
• Loosen the receiving eye wing nut to allow slight rotation of
unit. Adjust sensor vertically and/or horizontally until the
green indicator light glows steadily.
• When indicator lights are glowing steadily in both units,
tighten the wing nut in the receiving eye unit.
WIRING FOR LIFTMASTER COMMERCIAL OPERATORS
1/4-20x1-1/2"
Hex Bolt Wing Nut
Wing Nut
“C” Wrap
Sensor
Wire
Indicator Light
1/4-20 x 1-1/2"
Hex Bolt
Bell Wire
Secure Wire with
Insulated Staples
Connect Wire
to Commercial
Protector Interface
Sensor Beam
6" (15 cm) max. above floor
Sensor Beam
6" (15 cm) max. above floor
Invisible Light Beam
Protection Area