Lift-master BJ User Manual

Lift-Master
The Professional Line
OWNERS MANUAL
The Chmaberlain Group, Inc. A Unit of Duchossois Industries, Inc. 845 Larch Avenue, Elmhurst, Illinois 60126
MODEL BJ
BELT JACK
SERIES B
WIRING
TYPE
COMMERCIAL DOOR OPERATOR LISTED
TYPE STATION NUMBER FUNCTION
B 3 Button 453365 Momentary contact to open, close and stop. B1 3 Button 453639 Momentary contact to open, close and stop plus wiring for sensing
device to stop.
B2 3 Button 453642 Momentary contract to open, close and stop plus wiring for sensing
device to reverse and auxiliary devices to open and close with override.
C 3 Button 453636 Momentary contact to open and stop with constant pressure to
close.
C1 3 Button 453640 Momentary contact to open and stop with constant pressure to close
and wiring for sensing device to stop.
C2 3 Button 453643 Momentary contact to open and stop with constant pressure to
close. D 2 Button 453641 Constant pressure to open and close. D1 2 Button 453641 Constant pressure to open and close with wiring for sensing device
to stop. E 2 Button 453638 Momentary contact to open and constant pressure to close. Release
of close button will cause door to reverse (rollback feature). E2 2 Button 453644 Momentary contact to open with open override and constant
pressure to close. S 1 Button 453645 Momentary contact to open and close plus wiring for sensing device
to reverse, auxiliary devices to open and close, with open override. T 3 Button 453646 Momentary contact to open, close and stop with open override and
timer to close. Open button may be connected to activate timer if
desired. Auxiliary controls may be connected to open and activate to
close or to open and close, without activating timer. ST 1 Button 453647 “T” type wiring with single button instead of three button operation.
(See “S” type wiring.) TS 3 Button 453648 momentary contact open, close and stop with open override and
timer to close. EVERY device that causes door to open will activate
timer to close including sensing device to reverse. Timer may be
deactivated until next opening signal is received by depressing stop
button after door has reached open position or permanently by use
of optional timer defeat switch. Photo-cell or loop detector not
recommended for use as a sensing device to reverse with this wiring
type. STS 1 Button 453649 ‘TS” type wiring with single button instead of three button operation.
(See ‘S” type wiring.)
Notes: 1. External interlocks may be wired into all wiring types.
2. Auxiliary devices are any devices that have only one set of contacts. Examples are: photo-cell, loop detector, pneumatic or electric treadles,
residential radio controls, one button stations, pull cords\, etc.
3. open override means that the door may be reversed while closing by activating an opening device without the need to use the step button first.
Loading...
+ 8 hidden pages