Liebherr C1650 Installation Guide

Installation
Instructions
For Built-In NoFrost Combined
C 16
CI 16
7080 007-00
!
WARNING
CAUTION
!
IMPORTANT
PLEASE READ AND FOLLOW THESE INSTRUCTIONS
These instructions contain Warning and Caution statements. This information is important for safe and efficient installation.
Always read and follow all Warning and Caution statements!
States a hazard that may cause serious injury or death if precautions are not followed.
Signals a situation where minor injury of product damage may occur if you do not follow instructions.
Contents Page
Planning Information
Cabinet Opening Dimensions ..............................
Unit Dimensions ...................................................5
Integrating Cabinetry CI 16
Framed Panels ................................................... 6
Overlay Panels ................................................... 7
Handle Clearance .............................................. 8
Door Swing Clearance 130° .............................. 9
Door Swing Clearance 90° .............................. 10
Integrating Cabinetry C 16
Door Swing Clearance 130° ............................ 11
Door Swing Clearance 90° .............................. 12
Mounting the Upper Ventilation Grille .................... 13
Leveling the Refrigerator ........................................ 13
Blocking for Safety ................................................. 14
Door Stop Adjustment ............................................ 1
4
5
IMPORTANT
This highlights information that is especially relevant to a problem-free installation.
Make sure incoming voltage is the same as the unit rating.
To reduce the risk of fire, electric shock, or personal injury, installation work and electrical wiring must be done by a qualified electrician in accordance with all applicable codes and standards, including fire-rated construction.
TO THE INSTALLER
It is very important that the guidelines and instructions are followed in the manual to ensure proper installation and operation of the unit. The Installation Guidelines section contains important information for making sure the installation is correct. Read and understand all the information in Installation Guidelines, and in this manual before the unit is installed.
2
INSTALLATION GUIDELINES
!
WARNING
!
WARNING
!
WARNING
Area Requirements
Verify the following:
• Floors can support refrigerator’s weight plus approximately 1200 pounds (544 kg) of food weight.
• Finish kitchen floor height is level. Refrigerator must be shimmed to the floor level if the floor heights are not equal to make sure air vents are not obstructed.
• Remove anything attached to rear or side walls that can obstruct refrigerator opening.
ELECTROCUTION HAZARD
Electrical Grounding Required. This appliance is equipped with a three-prong (grounding) polarized plug for your protection against possible shock hazards.
DO NOT remove the round grounding
prong from the plug.
DO NOT use a two-prong grounding
adapter.
DO NOT use an extension cord to
connect power to the unit.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
Do not install this refrigerator-freezer next to any other refrigerator or model except another Liebherr model.Liebherr models are designed to allow side­by-side installation.They are equipped with a heating system to eliminate condensation when refrigerators or freezers are installed side-by-side. Installing this refrigerator-freezer next to any other refrigerator or freezer can cause condensation or cause damage to the Liebherr refrigerator-freezer.
Electrical Requirement
If codes require a separate grounding circuit to be used, have a qualified electrician install the circuit.
Do not ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. Do not have a fuse in the neutral or grounding circuit.
ELECTRICAL SHOCK HAZARD
• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions could result in fire or electrical shock.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-by­side installation) fused electrical supply is required. We recommend using a dedicated circuit for this appliance to prevent electrical overload. Follow the National Electrical Code and local codes and ordinances when installing the receptacle.
Blocking For Safety
The anti-tip brackets must be installed to prevent the unit from tipping after it is installed. Refer to Blocking For Safety.
Unit Venting
DO NOT restrict the air flow. Air flow must be provided for the unit to operate. The factory air vents provide 31 square inches (200 cm flow. If you are replacing the factory air vents with an overlay, the air flow must be the same or greater than the factory air vents.
2
) of air
Reversing the Door Hinges
If the hinges and door handles are reversed, you must obtain the Reverse Set. The Reverse Set is not included with the unit. Contact your Liebherr retailer, only for CI 16 unit. The door handles must be installed before the screw covers are installed. If you fail to install the handles before the screw covers, you can damage the covers. The screw covers are taped to the unit door during shipping. Use care when removing the covers.
3
PLANNING INFORMATION
Electrical outlet locatio
n
= =
83-7/8"
(213
0
mm)
85"
(215
9
mm)
18"
(457 mm)
3"
(7
6
mm)
2
4
(6
1
0
m
m
)
Single: 29-1 7/32” (750 mm) / SBS 59-1 2" (1511 mm)
Locate water supply within bottom shaded area
3"
(76 mm)
Cabinet Opening Dimensions
Allow units to open a minimum of 90° to prevent problems removing drawers. With the door opening 90°, you may have to move drawers slightly to clear the door interior.
Allow for a minimum 2" (51 mm) filler, for corner installations, so the door can open to 90°. If you’re using raised panels, consider using a wider filler.
IMPORTANT
Refer to the minimum door clearances and illustra tions at the end of this section for specifics on door openings and filler size alternatives.
NOTE: The given cabinet opening height dimension in­cludes top air vent. If you choose to place the vent above the cabinet or in a soffit, you will need to adjust the height dimension accordingly.
-
Figure 1
44
4
Unit Dimensions
30" (762 mm)
26" (660 mm)
90°
1
3
0
°
29" (737 mm)
23-5/16
(592 mm) "
30" (762 mm)
52-3/4" (1340 mm)
47" (1194 mm)
1-13/16 (46 mm)"
19" (482 mm)
DOOR SWING CLEARANCE
Front view
Air Vent
* Overall height can be increased 5/8" (16 mm) by turning the adjustable roller base
.
Side view
Top view
Optional factory air vent
maximum height 84-1/4" (2140 mm)
minimum height 83 5/8" (2124 mm)*
maximum height 81-11/16" (2075 m
m)
minimum height 81 - 1/16" (2059 m
m)*
24" (609 mm) - C 16 24-1/2" (620 mm) - CI 16
22-1/8" (562 mm)
PLANNING INFORMATION
Figure 2
55
5