Liberty Pumps X8-D User Manual

1
7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550 Fax: (585) 494-1839 www.libertypumps.com
Installation Manual 7264000D
8” Basin Extension PRO SERIES Model X8 FOR P380 AND P370 SYSTEMS Model X8-D FOR P680 SYSTEMS
Model X8 and X8-D Includes:
8” molded extension Rubber gasket seal  8 (16) stainless cover bolts  Discharge pipe extenders
©Copyright 2013 Liberty Pumps Inc. All rights reserved
2
X8 and X8-D Extension Installation
Before installing the X8 or X8-D, basin extension, the pump and cover must be removed from an assembled PRO system.
1.) Remove the small access cover which is secured by 6 fasteners.
2.) Remove the QuickTree® (float rod and floats) from the basin by lifting the unit out of its holder.
3.) Unscrew the fasteners securing the main cover to the tank. In order to remove the main cover it must be separated from the PVC discharge pipe. This can be done by rotating the cover back and forth while pulling upward.
Re-assembly:
1) The short length of pipe and the coupling must be “glued” to the current discharge pipe(s).
2) Place the pump(s) with pipe into the basin and position it within the torque stops. (The torque stops are the three round pockets located at the bottom of the basin.) Each leg of the pump should be in side one of the pockets.
3) The gasket can now be placed onto the tanks rim, match the holes in the gasket with the threaded inserts in the tank.
4) Lower the extension onto the gasket carefully as to not disturb the gasket.
5) Using the screws and washers provided, attach the extension to the tank. Note: an XL system will require 16 screws to provide proper claming load. The torque on the fastener should be 40 in*lbs IMPORTANT: do not over tighten.
6) Re-attach the main cover. To facilitate assembly, the PVC pipe should be wetted with soapy water and inserted into the rubber seal under the cover. The cover can be twisted back and forth while pushing down until the cover meets the extension. Re-attach the cover with the same screws that were removed. Note: XL-systems will have 16 screws.
7) A new longer QuickTree® rod is provided with the X8 extension. Remove the floats from the original QuickTree® rod by loosening the screw on the clamp. (For systems with an optional alarm, two floats need to be removed.)
8) Re-attach the floats to the new longer QuickTree® rod using the diagram (Figure 1 or 2) below. IMPORTANT: It is critical that the tether length remains the same on re-
installation. The tether length is the distance of cord from the clamp to the top of the float ball. See Figure 1 or 2. for proper lengths.
9) The new QuickTree® rod has four “flat” sections; the upper two are used in a P380 system and the lower two on a P370 system. The lowest float is the pump control followed by the alarm float if the system is equipped with the alarm option.
©Copyright 2013 Liberty Pumps Inc. All rights reserved