LG
LG Weekly Wired Remote Controller
Owner's & Installation Manual
Models: PVRCUSZ0
IMPORTANT
•Please read this owner's & installation manual completely before installing the product.
•Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
•Please retain this owner's & installation manual for future reference after reading it thoroughly.
Weekly Wired Remote Controller Owner’s & Installation Manual
TABLE OF CONTENTS
■ Safety Precaution ............................................................................................. |
3~4 |
■ Part Description ................................................................................................ |
5~6 |
■ Installation instruction ......................................................................................... |
7 |
■ Remote controller connection method ............................................................... |
8 |
■ Address setup of central control ........................................................................ |
9 |
■ Cooling operation ............................................................................................... |
10 |
Standard cooling ................................................................................................ |
10 |
Power cooling ..................................................................................................... |
11 |
■ Heating operation ............................................................................................... |
12 |
■ Temperature control ........................................................................................... |
13 |
Setting desired temperature................................................................................ |
13 |
The room temperature confirmation.................................................................... |
13 |
■ Fan Speed operation ......................................................................................... |
14 |
Fan Speed selector ............................................................................................. |
14 |
Air flow direction control ...................................................................................... |
14 |
■ Additional functions ........................................................................................... |
15 |
Auto operation..................................................................................................... |
15 |
Dehumidification operation ................................................................................. |
16 |
Fan operation ..................................................................................................... |
16 |
Setting current time ............................................................................................ |
17 |
Setting preset for weekly time ............................................................................. |
18 |
Setting holiday..................................................................................................... |
19 |
On preset ............................................................................................................ |
20 |
Off preset ............................................................................................................ |
20 |
Usage restriction function.................................................................................... |
21 |
Auto restarting Function ..................................................................................... |
21 |
Self diagnosis fuction ......................................................................................... |
21 |
Different mode operation..................................................................................... |
22 |
Safety Precaution
Safety Precaution
•The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company.
•For all the problems arising after installation by someone who has no relevant qualifications, our company will not provide free service.
•The following safety cautions are provided to prevent unexpected dangers or losses.
WARNING : If the user does not follow the mandatory items, it may result in serious injury or death.
CAUTION : If the user does not follow the mandatory items, it may cause personal injury or property damage.
:Warning and Caution are to call the user’s attention to the possible danger. Read and follow them carefully in order to prevent a safety accident.
:Warning and Caution are indicated in this guide and the product itself to help protect the users from danger.
WARNING
■ Installation
Be sure to request to the |
Request to the service center |
Do not disassemble, fix, and |
service center or installation |
or installation specialty store |
modify products randomly. |
specialty store when |
when reinstalling the |
|
installing products. |
installed product. |
|
• It will cause fire or electric shock |
• It will cause fire or electric shock |
• It will cause fire or electric shock. |
or explosion or injury. |
or explosion or injury. |
|
■ In-use
Do not place flammable |
Do not allow water to run |
Do not give the shock to the |
stuffs close to the product. |
into the product. |
product. |
• It will cause fire. |
• It will cause electric shock or |
• It will cause breakdown when |
|
breakdown. |
giving the shock to the product. |
|
Time |
|
2 Weekly Wired Remote Controller |
Owner’s & Installation Manual 3 |
Safety Precaution
Request to the service center or installation |
Do not give the shock using sharp and |
specialty store when the product becomes wet. |
pointed objects. |
• It will cause fire or electric shock. |
• It will cause breakdown by damaging parts. |
■ In-use
Do not clean using the |
Do not press the screen |
Do not touch or pull the lead |
powerful detergent like |
using powerful pressure or |
wire with wet hands. |
solvent but use soft cloths. |
select two buttons. |
|
• It will cause fire or product |
• It will cause product breakdown or |
• It will cause product breakdown or |
deformation. |
malfunction. |
electric shock. |
Part Description
Name and Function of Remote Controller
CVT TYPE
1
12
2
3
|
AUTO SWING |
OPERATION |
SET TEMP |
FAN SPEED |
SUB FUNCTION |
||||||
|
|
|
|
|
|
Room Temp |
HI |
AUTO |
Heater |
Preheat |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
MED |
JET |
Defrost |
Humidify |
|
|
|
|
|
|
|
|
LO |
SLo |
Filter |
Out door |
|
|
|
|
|
2ndF |
Time |
ZONE |
|
1 2 3 4 |
|||
|
Timer |
Operation unit |
No Func |
Program set |
|
|
|
|
|
||
|
On Off |
|
|
|
|
|
|
|
|
|
|
|
Set no. Time |
01 |
03 |
05 07 |
09 11 13 |
15 17 |
19 |
21 |
23 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Timer Cancel
Program Week Holiday
Set/Clr
RESET
Hour Min
|
1. |
Operation indication screen |
|
|
2. |
Power Wind button |
|
|
3. |
Timer set/cancel |
|
|
|
Program/Week/Holiday |
|
4 |
|
Hour/Min/SET/Clr/Ventilator |
|
4. |
Set temperature button |
||
5 |
|||
5. |
ON/OFF button |
||
6 |
|||
6. |
Fan operation |
||
|
77. Operation mode selection button
88. Fan speed button
9
10 9. Horizontal/Vertical air flow direction button
11 10. Horizontal Air Flow direction button
11. Time reset button
12. Operation lamp
Accessory
Connection wire(1) |
Remote control lock |
Owner's/installation Manual |
Insulation |
|
screw(5) |
|
|
|
|
|
|
4 Weekly Wired Remote Controller |
Owner’s & Installation Manual 5 |
Part Description
Information of slide switch
CVT TYPE
Room Temp. Sensing
Remo .
Indoor Unit
2TH(Remo+Indoor)
Ceiling Height
Low
Standard
High
Single
Group
Room Temperature Sensing select Switch
1.Use Remocon's sensor
2.Use Indoor's sensor
3.Use senor which has lower temrerature between Remocon's and indoor's
Ceiling Height select switch
1.Low
2.Standard
3.High
Group control select switch
1.Case of Single control
2.Case of Group control
When using Synchro operation, you must select "single" of group control switch.
Installation instruction
Installation instruction
1 Remove the sticker that is attached on back of insulation and attach the remote control on the wall you want to install.
2 Separate the cover of remote control like the right hand side.
3 Fix the setup board on top of the insulation.
wall insulation
remote control lock screw
4 Install each remote control with the distance of at least 2cm between them when installing several wired remote controls horizontally.
2cm
CAUTION
Before installing the wired remote controller, set the switch on the back of the wired remote controller to the required condition of the product.
Especially, if the switch exclusively for air conditioning and air conditioning/heating selection switch is incorrectly set, it can cause a problem to the product operation.
6 Weekly Wired Remote Controller |
Owner’s & Installation Manual 7 |