Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
Modbus Gateway Original instruction
MFL62179518
Rev.02_051419
Copyright © 2018 - 2019 LG Electronics Inc. All Rights Reserved.
МАКЕДОНСКИ
SHQIP ÍSLENSKA BOSANSKI
ČEŠTINA
NORSK
NEDERLANDS
SUOMI
POLSKI
DANSK
LIMBA ROMÂNĂ
EESTI KEEL
IMPORTANT SAFETY INSTRUCTIONS
2
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product.
!
WARNING
It can result in serious injury or death when the directions are ignored.
CAUTION
!
It can result in minor injury or product damage when the directions are ignored.
!
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
Installation
• Be sure to request to the service center or installation specialty store when installing products. It will cause fire or electric shock or explosion or injury.
IMPORTANT SAFETY INSTRUCTIONS
• Request to the service center or installation specialty store when reinstalling the installed product. It will cause fire or electric shock or explosion or injury.
• Do not disassemble, fix, and modify products randomly. It will cause fire or electric shock.
• Be sure to turn off power before installation. It will cause electric shock.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Always perform grounding.
- Otherwise, it may cause electrical shock.
• You need to use a safely insulated power supply which follows IEC61558-2-6 anc NEC Class2.
- If you do not follow, It may cause fire, electric shock, explosion
or injury.
• Securely attach the electrical part cover to Module.
- If the electric part cover of Module is not attached securely, it
could result in a fire or electric shock due to dust, water, etc.
3
ENGLISH
In-use
• Do not place flammable stuffs close to the product. It will cause fire.
• Do not allow water to run into the product. It will cause electric shock or breakdown.
• Do not give the shock to the product. It will cause breakdown when giving the shock to the product.
• Request to the service center or installation specialty store when the product becomes wet. It will cause fire or electric shock.
• Do not give the shock using sharp and pointed objects. It will cause breakdown by damaging parts.
• Do not touch the board when the power is connected. It can cause a fire, electric shock, explosion, injury and problem to the product.
IMPORTANT SAFETY INSTRUCTIONS
4
ENGLISH
• Unplug the unit if strange sounds, smell, or smoke comes from it.
- Otherwise, it may cause electrical shock or a fire.
• The appliance must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
• This appliance is not intended to be accessible to the general public.
CAUTION
!
In-use
• Do not clean using the powerful detergent like solvent but use soft cloths. It will cause fire or product deformation.
• Do not press the screen using powerful pressure or select two buttons. It will cause product breakdown or malfunction.
• Do not touch or pull the lead wire with wet hands. It will cause product breakdown or electric shock.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
ENGLISH Disposal of your old appliance
1. When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC.
2. All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilitiesappointed by the government or the local authorities.
3. The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health.
4. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product.
MODBUS GATEWAY SPECIFICATION
ڸڸڹ
ڻ
ڼ
ڿ
ں
ۀ
ھ
MODBUS GATEWAY SPECIFICATION
Components
Modbus Gateway (1 EA) Installation Manual (1 EA)
Part Description
Power : DC 12 V
ڹ
A+
+
ہ
LD01M
LD02M
ڻ
RS485 DIGITAL OUPUT
A+
ں
B-
-
CH1
12VDC
RS485
LD04M
LD03M
LD05M
ON
ON
1234 1234
SW_01M
ڽ
RST_2
CH2
B-
DI1
SW_02M
DI2
DIGITAL INPUT
LD06M
ڿ
GND
ڼ
DO1
DI3
DI4
GND
ھ
SW1
DO2
ۀ
RS485 (CH1) : To 3rd Party ControllerRS485(CH2) : To Outdoor UnitDIP Switch(SW_01M) : Not UsedDIP Switch(SW_02M) : Modbus Address
RST_2 : ResetSW1 : Not UsedDIGITAL INPUT(DI1~DI4) : Not UsedDIGITAL OUTPUT (DO1~DO2) : Not UsedDisplay (LED)
- LD01M / LD02M : BMS & 3rd party Tx / Rx
- LD03M / LD04M : Outdoor Unit Tx / Rx
- LD05M : Indoor Unit Searching
- LD06M : Error
Setting
5
ENGLISH
CAUTION
!
• This model requires external power supply (DC 12 V) (Select an insulating transformer that complies with IEC61558-2-6 and NEC Class 2.)
• Please check the product operation range below.
Power supply DC 12 V
Product operation range
Ambient temperature -20 ~ 65 °C
Humidity 0 ~ 98 % (Non-condensing)
MODBUS GATEWAY INSTALLATION
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
6
ENGLISH
MODBUS GATEWAY INSTALLATION
Installation Method
When installing the Modbus Gateway, please fix and install using Din Rail And then it should be setting modbus address. (Modbus Address Setting : SW_02M) Refer to 'Installation Scene' about modbus address and wiring.
(Example of Installation)
Modbus Address Table (SW_02M)
h When factory shipped, Modbus address default is "1".
Din Rail
Modbus Address
1
2
3
4
5
6
7
8
SW_02M
DIP S/W No.
1 2 3 4
OFF OFF OFF OFF
OFF OFF OFF ON
OFF OFF ON OFF
OFF OFF ON ON
OFF ON OFF OFF
OFF ON OFF ON
OFF ON ON OFF
OFF ON ON ON
Modbus Address
9
10
11
12
13
14
15
16
SW_02M
DIP S/W No.
1 2 3 4
ON OFF OFF OFF
ON OFF OFF ON
ON OFF ON OFF
ON OFF ON ON
ON ON OFF OFF
ON ON OFF ON
ON ON ON OFF
ON ON ON ON
MODBUS GATEWAY INSTALLATION
ṿṿṿ
(Modbus Gateway)
Bus-A
Bus-B
(BMS & 3rd Party)
(Installation Example)
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
Bus-A Bus-B
(ODU)
Installation Scene
Case 1. Single Module Installation Scene
Indoor unit can be connected up to 16 unit
CAUTION
!
• When connecting to an outdoor unit, it must be connected to the master unit of each outdoor
unit.
• The communication line needs to match the A and B polarities. If it is incorrect, it will not
work.
• First power on the indoor unit and the outdoor unit and then power on the Modbus Gateway
after 3 minutes. Otherwise, it will not work properly.
• The address of indoor unit must be set only from 00 to 3F. Otherwise, the address can not
be recognized by the Modbus Gateway.
7
ENGLISH
CAUTION
!
• For the wired Power wire, Communication wire and Signal wire,
remove the coating at the end of the wire to connect and than use the pin type (JOBN153) to connect to the terminal block
• All field supplied parts and materials and electric works must be
conform to local codes.
• Use copper wire only.
• All wiring must be performed by an authorized electrician.
<Fig.1>
Pin type (JOBN153)
MODBUS GATEWAY INSTALLATION
(ODU)
Modbus
address : 2
Modbus
address : 3
Modbus
address : 4
(ODU) (ODU) (ODU)
Bus-A Bus-B
SLAVE #1 IDU : Max. 32 Unit
SLAVE #2 IDU : Max. 48 Unit
SLAVE #3 IDU : Max. 64 Unit
MASTER IDU : Max. 16 Unit
Bus-A
Bus-B
Bus-A
Bus-B
(BMS & 3rd Party)
(Installation Example)
ṿṿṿ
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234
LD04M
LD03M
LD06M
LD05M
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234
LD04M
LD03M
LD06M
LD05M
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
1234
SW_02M
ON
1234
SW_02M
ON
1234
ON
1234
ON
1234
ON
8
ENGLISH
Case2. Series Module Installation Scene
The master module can connect up to three slave modules.
- The number of indoor units that can be connected depends on the number of modules.
- The Modbus address of each slave modules are fixed. (Reference in Fig 2. / Modbus Address Setting : SW_02M)
The number of Modbus Gateway Indoor Unit
Master Max. 16 Unit Master + Slave(1 Module) Max. 32 Unit Master + Slave(2 Module) Max. 48 Unit Master + Slave(3 Module) Max. 64 Unit
<Table 1>
CAUTION
!
• The number of connectable indoor units must be matched as shown in Table 1. Otherwise it will not work.
• If one or more modules of the Modbus Gateway connected in the Series broken, the indoor unit is not controlled normally.
• Master module address setting and Slave module address setting do not affect each other.
<Fig.2>
MODBUS GATEWAY INSTALLATION
Bus-A
Bus-A Bus-B Bus-A Bus-B Bus-A Bus-B Bus-A Bus-B
Bus-B
(ODU) (ODU) (ODU) (ODU)
MASTER #1 MASTER #2 MASTER #3 MASTER #4
(BMS & 3rd Party)
(Installation Example)
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
SW1
RST_2
12VDC
CH1
DI1
DI2
DI3
DI4
GND
GND
A+
B-
+
-
RS485
CH2
DO1
DO2
A+
B-
RS485 DIGITAL OUPUT
DIGITAL INPUT
ON
SW_01M
LD01M
LD02M
1234 1234
SW_02M
ON
LD04M
LD03M
LD06M
LD05M
Case3. Single module combination Installation Scene
1. The number of indoor units that can be connected to the system increases depending on the number of Master modules.
2. It can be connected up to 16 indoor unit per master module.
- It can be connected up to 64 indoor unit through combination Installation
3. It should be set different address each master unit. (Modbus Address Setting : SW_02M)
CAUTION
!
• If the address of each master module is the same, it will not work.
• If more than 16 indoor units are connected to each Master module, it will not operate
normally.
9
ENGLISH
<Fig.3>
ENGLISH
Appendix 1
Appendix 1. MODBUS GATEWAY MEMORY MAP
MODBUS GATEWAY MEMORY MAP
Baud Rate : 9 600 bps Stop Bit : 1 stop bit Parity : None Parity
Coil Register (0x01)
No.
Air Conditioner Ventilator / DX Vetilator HydroKit & AWHP 1 Operate (On/Off) Operate (On/Off) Operate (On/Off) 0: Stop / 1: Run 2 Auto Swing Aircon Operate (On/Off) Hot Water Mode (On/Off) 0: Disable / 1: Enable 3 Filter Alarm Release Filter Alarm Release 4 Lock Remote Controller Lock Remote Controller Lock Remote Controller 0: UnLock / 1: Lock 5 Lock Operate Mode Lock Operate Mode 6 Lock Fan Speed Lock Fan Speed1)Reserved 0: UnLock / 1: Lock 7 Lock Target Temp. Lock Target Temp. 8 Lock IDU Address Lock IDU Address 9 Reserved Quick Ventilate Reserved 0: Disable / 1: Enable
10 Reserved EnergySave Reserved 0: Disable / 1: Enable
1)
* Note
: This register value is applied 'DX Ventilator' ONLY.
Discrete Register (0x02)
No.
Air Conditioner Ventilator / DX Vetilator HydroKit & AWHP
10001 Connected IDU Connected IDU Connected IDU 0: Disconnected / 1: Connected 10002 Alarm Alarm Alarm 0: Normal / 1: Alarm
10003 Filter Alarm Filter Alarm
10004 Reserved Reserved Target Temp Select 0: Air / 1: Water 10005 Reserved Reserved Error Division
1)
* Note
: This register value is applied 'DX Ventilator' ONLY.
* Note2): This register value is applied ‘Hydrokit' ONLY.
Holding Register (0x03)
No.
Air Conditioner Ventilator / DX Vetilator HydroKit & AWHP
40001 Operate Mode Operate Mode Operate Mode
40002 Fan Speed Fan Speed Target Temp. DHW2)1 : Low, 2 : Mid, 3 : High, 4 : Auto 40003 Target Temp. Target Temp.
Target Temp. Limit
40004
40005
40006 Reserved Vent. Operate Mode Reserved 0 : HEX, 1 : Auto, 2 : Normal
* Note * Note2): This value range can be between 0 ~ 127[°C]. And it would be limited by upper & lower value according to the setting of remote controller.
(Upper)
Target Temp. Limit
(Lower)
1)
: This register value is applied 'DX Ventilator' ONLY.
Input Register (0x04)
No.
Air Conditioner Ventilator / DX Vetilator HydroKit & AWHP
30001 Error Code Error Code Error Code
30002 Room Temp. RA Temp. Room Temp. -99.0 ~ 99.0 [°C] X 10 30003 Pipe In Temp. OA Temp. 30004 Pipe Out Temp. SA Temp. 30005 Reserved Pipe In Temp. 30006 Reserved Pipe Out Temp.
1)
* Note
: This register value is applied 'DX Ventilator' ONLY.
2)
* Note
: This register value is applied ‘AWHP' ONLY.
Data Bit
Data Bit
1)
Data Bit
1)
Target Temp. Limit
(Upper)
Target Temp. Limit
(Lower)
Data Bit
1)
1)
1)
Function Register
1)
Reserved 0: Normal / 1: Alarm Release
1)
Reserved 0: UnLock / 1: Lock
1)
Reserved 0: UnLock / 1: Lock
1)
Reserved 0: UnLock / 1: Lock
Function Register
Hot Water Only
2)
2)
0: Normal / 1: Alarm
Hydrokit – 0: Normal /
1: Hot Water Only
0: CH type error / 1: BC type error
Function Register
0: Cooling, 1: Dehumidifying, 2: Fan, 3: Auto, 4: Heating Hydrokit (Middle Temp. DHW)/AWHP – 0:Cooling, 3:Auto, 4:Heating Hydrokit(High Temp. DHW) – 3:Auto, 4:Heating
2)
Target Temp.
1)
Reserved 16.0 ~ 30.0 [°C] X 10
1)
Reserved 16.0 ~ 30.0 [°C] X 10
16.0 ~ 30.0 [°C] X 10
Function Register
0 ~ 255 Please refer to the product
error table.
Water Inlet Temp. -99.0 ~ 99.0 [°C] X 10
Water Outlet Temp. -99.0 ~ 99.0 [°C] X 10
Sanitary Tank Temp. -99.0 ~ 99.0 [°C] X 10
1)
Solar Temp.
2)
-99.0 ~ 99.0 [°C] X 10
Register = N X 16 + (N = Indoor Unit Central Address)
Register = N X 16 + (N = Indoor Unit Central Address)
Register = N X 20 + (N = Indoor Unit Central Address)
Register = N X 20 + (N = Indoor Unit Central Address)
11
ENGLISH
The above information applies only to India.
ENGLISH
12
EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands Manufacturer: LG Electronics Inc. Changwon 2nd factory, 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA