LG MS3447GRS, MS3447GR User Manual

Internal Use Only
Website http://biz.lgservice.com
MICROWAVE OVEN
SERVICE MANUAL
MODEL: MS3447GR
CAUTION
BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
P/NO : MFL31039007
MS3447GRS
Printed in Korea
SAFETY PRECAUTIONS
This device is to be serviced only by properly qualified service personnel. Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be taken to avoid possible exposure to excessive microwave energy.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
A) Do not operate or allow the oven to be operated with the door open.
B) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary; (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.
C) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
D) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.
E) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
CAUTION
MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM THE MICROWAVE GENERATOR OR OTHER PARTS CONDUCTING MICROWAVE ENERGY.
Only for training and service purposes
LGE Internal Use OnlyCopyright © 2007 LG Electronics. Inc. All right reserved.
CONTENTS
(Page)
SAFETY PRECAUTIONS
SPECIFICATIONS
CAUTIONS
---------------------------------------------------------------------------------------------------------------
INSTALLATION
-----------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------
OPERATING INSTRUCTIONS
FEATURES
CONTROL PANEL
OPERATING SEQUENCE
SCHEMATIC DIAGRAM
CIRCUIT DESCRIPTION
------------------------------------------------------------------------------------------------------------------------
SERVICE INFORMATION
TOOLS AND MEASURING INSTRUMENTS
MICROWAVE LEAKAGE TEST
MEASUREMENT OF MICROWAVE POWER OUTPUT
----------------------------------------------------------------------
------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------
---------------------------------------------------------------------------
--------------------------------------------------------------------------------------------
Inside front cover
1-1
2-1
3-1
4-1
4-1
4-1
4-2
4-4
4-5
5-1
5-1
5-1
-----------------------------------------------------------
5-3
DISASSEMBLY AND ADJUSTMENT
INTERLOCK CONTINUITY TEST
COMPONENT TEST PROCEDURE
TROUBLE SHOOTING
EXPLODED VIEW
------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
REPLACEMENT PARTS LIST
-------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
5-3
5-7
5-8
5-11
6-1
------------------------------------------------------------------------------------
7-1
LGE Internal Use Only Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
SPECIFICATIONS
ITEM
MODEL
Power Requiremen
Power Output
Microwave Frequency
Magnetron
Timer
Outside Dimensions
Cavity Dimensions
Net Weight
Shipping weight
Control Complement
DESCRIPTION
MS3447GR / MS3447GRS
230/240 Volts AC 50 Hz 1600 Watts Single phase, 3 wire grounded
1100 Watts full microwave power (IEC60705)
2450 MHz
2M246-050GF
0 ~ 99 min. 99 sec.
556mm (W) x 320mm (H) x 438mm (D)
374mm (W) x 254mm (H) x 406mm (D)
16.5 kg (approx.)
17.9 kg (approx.)
Touch Control System
Clock : 1:00 - 12:59
Microwave Power for Variable Cooking
Power level
HIGH .................................... Full power throughout the cooking time
9 (Saute)
7 (Med.-High)
5 (Med.-Low)
3 (Low)
1 (Warm)
...............................
.......................
........................
.................................
..............................
approx. 90% of Full power, 8 (Reheat)
approx. 70%, 6 (Medium)
approx. 50%, 4 (Defrost)
approx. 30%, 2 (Simmer)
approx. 10%
..........
..........
approx. 80%
.........
approx. 60%
approx. 40%
.........
approx. 20%
Rating Label
Accessories
This microwave oven is designed for household use only.
It is not recommended for commercial purposes.
Only for training and service purposes
Location
Owner's manual & cooking guide
Glass turntable
Roller rest
1-1
LGE Internal Use OnlyCopyright © 2007 LG Electronics. Inc. All right reserved.
CAUTIONS
Unlike other appliances, the microwave oven is high-voltage and high-current equipment. Though it is free from danger in ordinary use, extreme care should be taken during repair.
• DO NOT operate on a 2-wire extension cord during repair and use.
• NEVER TOUCH any oven components or wiring during operation.
• BEFORE TOUCHING any parts of the oven, always remove the power plug from the outlet.
• For about 30 seconds after the oven stops, an electric charge remains in the high voltage capacitor. When replacing or checking, you must discharge the high voltage capacitor by shorting across the two terminals with an insulated screwdriver.
MICROWAVE RADIATION
Personnel should not be exposed to the microwave energy which may radiate from the magnetron or other microwave generating device if it is improperly used or connection. All input and output microwave connections, waveguide, flange, and gasket must be secure never operate the device without a microwave energy absorbing load attached. Never look into an open waveguide or antenna while the device is energized.
• Proper operation of the microwave oven requires that the magnetron be assembled to the waveguide and cavity. Never operate the magnetron unless it is properly installed.
• Be sure that the magnetron gasket is properly installed around the dome of the tube whenever installing the magnetron.
ANTENNA
Gasket
• Remove your watches whenever working close to or replacing the Magnetron.
• DO NOT touch any parts of the control panel circuit. A resulting static electric discharge may damage this P. C . B .
• NEVER operate the oven with no load.
• NEVER injure the door seal and front plate of the oven cavity.
• NEVER put iron tools on the magnetron.
• NEVER put anything into the latch hole and the interlock switches area.
COOLING FIN
FILAMENT TERMINALS
MAGNETRON CHASSIS GROUND
MAGNETRON
THE OVEN IS TO BE SERVICED ONLY BY PROPERLY QUALIFIED SERVICE PERSONNEL.
LGE Internal Use Only Copyright © 2007 LG Electronics. Inc. All right reserved.
2-1
Only for training and service purposes
INSTALLATION
BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY.
INSTALLING
1. Empty the microwave oven and clean inside it with a soft, damp cloth. Check for damage such as misaligned door, damage around the door or dents inside the cavity or on the exterior.
2. Put the oven on a counter, table, or shelf that is strong enough to hold the oven and the food and utensils you put in it. (The control panel side of the oven is the heavy side. Use care when handling.)
3. Do not block the vent and the air intake openings. Blocking vent or air intake openings can cause damage to the oven and poor cooking results. Make sure the microwave oven legs are in place to ensure proper air flow.
4. The oven should not be installed in any area where heat and steam are generated, because they may damage the electronic or mechanical parts of the unit. Do not install the oven next to a conventional surface unit or above a conventional wall oven.
5. Use microwave oven in an ambient temperature less than 104°F(40°C).
EARTHING INSTRUCTIONS
This microwave oven is designed to be used in a fully earthed condition. It is imperative, therefore, to make sure it is properly earthed before servicing
WARNING­THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in this mains lead are colored in accordance with the following code:
Green-and-yellow: Earth Blue: Neutral Brown: Live
As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plug, proceed as follows.
6. Place the microwave oven on a sturdy and flat surface at least 10 cm(4 inches) from the wall.
7. Place the microwave oven as far away as possible from TV, RADIO, COMPUTER, etc., to prevent interference.
10cm
Only for training and service purposes
The wire which is colored green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol ( ) or colored green or green-and-yellow.
The wire which is colored blue must be connected to the terminal in the plug which is marked with the letter N or colored black.
The wire which is colored brown must be connected to the terminal in the plug which is marked with the letter L or colored red.
3-1
LGE Internal Use OnlyCopyright © 2007 LG Electronics. Inc. All right reserved.
OPERATING INSTRUCTIONS
FEATURES
CONTROL PANEL
1. SENSOR REHEAT.
2. SENSOR COOK.
3. AUTO COOK: Used to select the auto cook
1
2
34
5
8
9
11
6
7
10
12
4. AUTO REHEAT: Used to select the auto reheat.
5. AUTO DEFROST: This feature provides you with the best
defrosting method for frozen foods.
6. MORE / LESS:
can be adjusted to cook food for a longer or shorter time.
MORE Pressing MORE will add 10 seconds to the
LESS Pressing LESS will subtract 10 seconds of
7. QUICK-DEFROST: You can thaw specific foods and
weight very quickly.
8. NUMBER: These used to set for time of day, cooking time,
power level, or defrost weight.
9. CLOCK: It is used to set the time of day.
10. POWER: You can select power level for cooking.
11. STOP/CLEAR: It used to stop oven and clear all entries
except time of day.
12. START/Q-START: To quickly set the cooking time
directly.
All of the one touch cook and TIMED COOK
cooking time.
cooking time.
LGE Internal Use Only Copyright © 2007 LG Electronics. Inc. All right reserved.
4-1
Only for training and service purposes
OPERATING SEQUENCE
The following is a description of component functions during oven operation.
1. CANCEL FUNCTION
Touch the STOP/CLEAR pad whenever you need to cancel an entry or a function currently in use. The display will return either to the last item entered or to the clock.
2. AUTO TOUCH
STOP/CLEAR
NOTE: • Heat only 1 package at a time
• Then the oven will start automatically.
POPCORN NUMBER OF TABLE
3. TIME COOKING
STOP/CLEAR
TIME
NUMBER
POWERNUMBER
START
4. MULTI-STAGE COOKING
You can program your oven to switch from one power level to another for up to 3 stages. To set a 2-stage cook cycle.
1ST STAGE
STOP/CLEAR
TIME
POWERNUMBER
6. CHILD LOCK
This oven has a CHILD LOCK feature TO SET CHILD LOCK
• Touch STOP/CLEAR pad
• Touch and hold STOP/CLEAR pad LOCKED
appears on the display.
TO CANCEL CHILD LOCK
• Touch and hold STOP/CLEAR pad LOCKED
disappears.
7. MORE / LESS
The cook time is adjustable by MORE pad or LESS pad
STOP/CLEAR COOKING MORE/LESS
8. AUTO REHEAT
STOP/CLEAR
NOTE: Then the oven will start automatically.
AUTO
REHEAT
NUMBER OF TABLE
9. Q UICK DEFROST
STOP/CLEAR QUICK DEFROST
NUMBER
2ND STAGE
TIME
NUMBER
START
5. AUTO DEFROST COOKING
STOP/CLEAR
NUMBER OF
WEIGHT
Only for training and service purposes
AUTO
DEFROST
START
NUMBER
10. AUTO COOK
STOP/CLEAR AUTO COOK
POWERNUMBER
NOTE: Then the oven will start automatically.
4-2
NUMBER OF TABLE
LGE Internal Use OnlyCopyright © 2007 LG Electronics. Inc. All right reserved.
SCHEMATIC DIAGRAM
LGE Internal Use Only Copyright © 2007 LG Electronics. Inc. All right reserved.
4-3
Only for training and service purposes
CIRCUIT DESCRIPTION
FUSE
H.V.
TRANS-
FORMER
RELAY 2
MICOM CONTROLLER
SECONDARY SWITCH
PRIMARY SWITCH
MONITOR
SWITCH
L
N
GENERAL DETAILS
• The low voltage transformer supplies the necessary
voltage to the micom controller when power cord is plugged in.
• When the door is closed, the primary switch is ON, the
secondary switch is ON, and the monitor switch opens (contact COM and NO).
WHEN SELECTING COOKING POWER LEVEL AND TIME
• The micom controller memorizes the function you set.
• The time you set appears in the display window.
• Each indicator light turns on to indicate that the stage
has been set.
WHEN TOUCHING THE START PAD
• The coil of the relay is energized by the micom
controller.
• Power input is supplied to the high voltage transformer
through the fuse to the primary switch and relay 2.
• Turntable rotates.
• A high voltage of approximately 2100 volts AC is generated in the secondary of the high voltage transformer which is increased by the action of the high voltage diode and charging of the high voltage capacitor.
• The negative 4000 Volts DC is applied to the filament of the magnetron.
WHEN THE OVEN IS SET AT ANY LEVEL EXCEPT MAXIMUM.
• The micom controller controls the ON-OFF time of relay 2 by the applied signal to vary the average output power of microwave oven as POWER LEVEL. (refer to page 1-1)
• One complete cycle of relay 2 is 22 seconds.
WHEN THE DOOR IS OPENED DURING COOKING
• Both the primary switch and relay 2 cut off the primary winding voltage of the high voltage transformer.
• ON-OFF of relay 2 is coupled electrically with opening and closing of the secondary switch.
• When the door is opened, the secondary switch is opened and when the door is closed, the secondary switch is closed.
• The cooking time stops counting down.
• Relay stops functioning.
• As the door is opened, if the contact of primary switch and relay 2 and/or secondary switch fail to open, the fuse opens due to the large current surge caused by the monitor switch activation, which in turn stops magnetron oscillation.
• The fan motor rotates and cools the magnetron by
plate).
blowing the air (coming from the intake on the base-
• The air is also directed into the oven to exhaust the vapor in the oven through the upper plate.
• Cooking time starts counting down.
• 3.3 volts AC is generated from the filament winding of the high voltage transformer. This 3.3 volts is applied to the magnetron to heat the magnetron filament through two noise-preventing choke coils.
Only for training and service purposes
4-4
FUSE
PRIMARY SWITCH
L
MONITOR
SWITCH
H.V.
TRANS-
FORMER
N
RELAY 2
MICOM CONTROLLER
SECONDARY SWITCH
LGE Internal Use OnlyCopyright © 2007 LG Electronics. Inc. All right reserved.