TABLE OF CONTENTS

FEATURES

2

OPERATING

4

FUNCTION

4

VENTILATION

8

TO CONTROL AIR DIRECTION

8

HOW TO ATTACH DRAIN PAN

10

AIR FILTER CLEANING

10

HOW TO ATTACH FRONT GRILLE TO CABINET

12

INSTALLATION

13

HOW TO INSTALL THE UNIT

13

HOW TO USE THE REVERSIBLE INLET GRILLE

14

WARNINGS

15

PLEASE CHECK BEFORE SERVICE CALL

16

BASIC CHARACTERISTICS

18

FEATURES

1

5

7

6

4

3

10

2

8

9

15

12

13

14

11

1. CABINET

 

 

 

 

 

7. AIR FILTER

 

 

 

 

 

 

 

2. HORIZONTAL AIR DEFLECTOR

 

 

8. CONTROL PANEL

 

 

 

 

 

(VERTICAL LOUVER)

 

 

 

9. POWER CORD

 

 

 

 

 

 

3. VERTICAL AIR DEFLECTOR

 

 

10. EVAPORATOR

 

 

 

 

 

 

(HORIZONTAL LOUVER)

11. CONDENSER

4. AIR DISCHARGE

12. COMPRESSOR

5. FRONT GRILLE

13. BASE PAN

6. AIR INTAKE

14. BRACE

(INLET GRILLE)

15. COVER CONTROL _2_

LG LWH182MGAB0 Owner’s Manual

.........................................................................................................

............................................................................................................

........................................................................................................

.........................................................................................................

..............................................................................................

.........................................................................................

..........................................................................

................................................................................

........................................................................................................

...............................................................................................

...............................................................................

........................................................................................................

......................................................................................

1

5

7

6

4

3

10

2

8

9

15

12

13

14

11

_3_

OPERATING

• CAUTION

When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again.

FUNCTION

 

Thermostat

Auto Swing

 

Operation

 

 

5

 

Off

0

 

 

 

4

6

 

 

 

 

Med

 

High

 

Off

On

 

 

 

 

Fan

 

Cool

3

7

 

 

 

 

2

8

 

 

 

 

1

9

 

Low

 

Med

 

Fan

 

Cool

 

 

 

 

Low Cool

 

• THERMOSTAT

Thermostat will automatically control the temperature of the room. Select higher number for lower room temperature. The temperature is selected by turning the knob to the desired position.

The 5 or 6 position is a normal setting for average conditions.

• AUTO SWING

ON (

): Air swing is operated while

 

OPERATION knob is set to the

 

COOL position.

OFF(

) : Stops the operation of air swing.

• OPERATION

OFF

( 0

)

: Turns the air conditioner

 

 

 

off.

MED FAN

(

)

: Permits the med fan

 

 

 

speed operation without

 

 

 

cooling.

LOW FAN

(

)

: Permits the low fan speed

 

 

 

operation without cooling.

HIGH COOL (

) : Permits cooling with the

 

 

 

high fan speed operation.

MED COOL (

) : Permits cooling with the

 

 

 

med fan speed operation.

LOW COOL (

) : Permits cooling with the

 

 

 

low fan speed operation.

_4_

 

Thermostat

Auto Swing

 

Operation

 

 

5

 

Off

0

 

 

 

4

6

 

 

 

 

Med

 

High

 

Off

On

 

 

 

 

Fan

 

Cool

3

7

 

 

 

 

2

8

 

 

 

 

1

9

 

Low

 

Med

 

Fan

 

Cool

 

 

 

 

Low Cool

 

: ( ) O N •

: ( ) OFF•

 

( 0 ) : O F F •

: (

) ME D FAN•

: (

) LO W FAN•

: (

) HIGH COOL•

: (

) MED COOL•

: (

) LOW COOL•

_5_

• CAUTION

When the air conditioner has been performing its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again.

FUNCTION

• THERMOSTAT

Turn the thermostat control to the desired setting. The control position is a normal setting for average conditions. You can change this setting, if necessary, in accordance with your temperature preference.

The thermostat automatically controls cooling or heating, but the fan runs continuously whenever the air conditioner is in operation. If the room is too warm, turn the thermostat control clockwise. If the room is too cool, turn the thermostat control counterclockwise.

• OPERATION

 

 

OFF

 

 

(

O )

: Turns the air conditioner

 

 

 

 

 

off.

LOW FAN

(

)

: Permits the low fan speed

 

 

 

 

 

operation without cooling

 

 

 

 

 

(heating).

LOW COOL (

)

: Permits cooling with the

 

 

 

 

 

low fan speed operation.

HIGH COOL (

)

: Permits cooling with the

 

 

 

 

 

high fan speed operation.

LOW HEAT

(

)

: Permits heating with the

 

 

 

 

 

low fan speed operation.

HIGH HEAT (

)

: Permits heating with the

 

 

 

 

 

high fan speed operation.

• AUTO SWING

 

ON

(

 

)

: Air swing is operated while

 

 

 

 

OPERATION knob is set to

 

 

 

 

the COOL or HEAT position.

OFF

(

 

)

: Stops the operation of air

 

 

 

 

 

swing.