Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours.
In the first 30 minutes set temperatur e increases by 1°C and in the next 30 minutes temperature
increases by another 1°C, thi s temperature then remains till the timer function is deactivated .
FAN SPEED SELECTOR
4
Select the fan speed in Three steps Low (F1) / Med. (F2) / High (F3)
ROOM TEMPERATURE SETTING BUTTON
5
Control the room temperature within a range of 16°C to 30°C.
AUTO SWING
6
The ver tical louver swings horizontally by the automatic system and stops when you press the
button again.
7
SIGNAL RECEIVER
AIR PURIFIER (For Plasma Model)
8
Used to start or stop plasma purification system. Clean filter indication will be 'ON' on panel,
when filter cleaning is required.
SLEEP BUTTON
9
Sleep function can be set by one hour for a maximum of 7 hours. In the first 30 minutes set
temperature increases by 1°C and in the next 30 minutes temperature increases by another
1°C, this temperature then remains till the timer function is deactivated. This is how the
sleep function behaves. The fan speed will change to low speed(F1).
Operation modes may vary in select models.
Fan speed in two steps Low (F1) / High (F2) in select models.
AUTO RESTART
In failure of electric power the unit runs as previous set ting operat ion when power ret urns.
NOTE: ‘SLEEP’ and ‘TIMER’ function cannot operate at same time.
How to Insert the Batteries
Remove the cover from the back of the remote
1
controller.
Slide the cover according to the arrow direction.
Insert the two batteries.
2
Be sure that the (+) and (-) directions are correct.
Be sure that both batteries are new.
Re-attach the cover.
3
Slide it back into the position.
Do not use rechargeable
batteries, such batteries differ
from standard dry cells in shape,
dimensions, and performance.
Remove the batteries from the
remote controller if the air
conditioner is not going to be
used for an extended length of
time.
04-
Your Panel may look l ike any
of below mentioned panels.
23
Mode Timer
Fan
Type 1
Cool On
Dry Energy Saver
FAN
SPEED
Fan SpeedTemp
4
Fan
Cool
Type 2
V
22
V
V
AUTO
SWING
5
Timer
6
22
V
TempPower
5
ON/OFF
REMOTE CONTROLLER
7
1
5
3
7
( )
2 b
POWER
DOWNUP
FAN SPEED
TIMER COOLING/FAN
ENERGY SAVER AUTO SWING
REMOTE CONTROLLER
1
5
4
2
6
3
( )
2 b
POWER
DOWNUP
FAN SPEED
TIMER COOLING/FAN
ENERGY SAVER AUTO SWING
1
4
2
6
1
Type 3
Type 4
COOL
DRY
FAN
ENERGY SAVER ON
Mode Timer
(e)
EN ER GY SAV ER
COOL
FAN
FAN
SPEED
7
88
AUTO
SWING
427361
88
TEMP
ON/OFF
TEMP
ON/OFF
5
Temp
9
5
Temp
P
o
w
e
r
1
5
V
V
F
a
n
S
pe
e
d
4
S
l
e
e
p
T
i
m r
e
2
M
o
d
e
63
A
u
t
o
S in
w
g
A
i
r
P
u
r
i e
f
i
r
P e
o
w
8
9
r
1
5
5
V
V
F p
a
n
S
e
e
d
4
S
l p
e
e
T
i
m
e
r
2
M
o
d
e
63
A
u
t
o
S
w
i
n
g
AUTO SWING
1
Controls
Precaution:
POWER BUTTON
1
Operation starts, when this button is pressed and stops when you press the button again.
OPERATION MODE SELECTION BUTTON
2
Select (a)Cool (b)Energy Saver (c)Fan & (d)Dehumidification (dry) with this button.
Energy saver mode-fan stops when compressor stops cooling. Approximately after 3
minutes fan will turn on to determine it cooling is needed. In dry mode, unit will run at
low fan speed only with compressor ‘ON’.
The Remote Control unit will not function properly if strong light strikes the sensor
window of the air conditioner or if there are obstacles between the Remote Control
unit and the air conditioner.
FAN SPEED
MODE
TEMP
POWER
1
4
2
6
-9-
Your Panel may look li ke any of below mentione d pan els.
(a)
FUZZY
DRY JET
CL
ENERGY
88 88
SAVER
INDOOR DESIRED
MODEFAN
2
4
AUTO SWING
POWER (ON/OFF) BUTTON
1
Operation starts, when this button is pressed and stops when you press the button again.
OPERATION MODE SELECTION BUTTON
2
Select (a) Cool, (b) Energy Saver, (c) Fuzzy & (d) Dry. In dry mode, unit will run at low fan speed only
with compressor 'ON'. When compressor is 'OFF', fan will be off.
During Energy Saver mode, fan stops when compressor stops cooling. Approximately after 3 minutes
fan will turn ON to determine if cooling is needed. If cooling is not needed, the fan turns OFF again.
ON/OFF TIMER
3
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours. In case of Auto
Restart, ON/OFF Timer is automatically cancelled.
FAN SPEED SELECTOR
4
Select the fan speed in Three steps Low / Med / High
ROOM TEMPERATURE SETTING BUTTON
5
Control the room temperature within a range of 18°C to 30°C.
AUTO SWING
6
The vertical louver swings horizontally by the automatic system and stops when you press the button again.
7
SIGNAL RECEIVER
FOR PLASMA M ODEL-
8
Used to Start or Stop the Plasma Purification function.
TEMP
TIMER
6
3
5
(b)
CLEAN
FILTER
10
AIR
PURIFIER
99
7
ON/OFF
1
FUZZY
DRY JET
ENERGY
88 88
SAVER
INDOOR DESIRED
MODEFAN
2
4
Air
TIMER
Purifier
8
3
AIR PURIFIER
CL
TEMP
5
CLEAN
FILTER
PURIFIER
ON/OFF
(c)
10
AIR
1
4
7
3
7
2
FUZZY
DRY JET
ENERGY
SAVER
CLEAN
FILTER
ON/OFF
AIR
PURIFIER
10
9
1
5
CL
88 88
INDOOR DESIRED
FAN
TIMER
SPEED
TEMP
AUTO
MODE
SWING
6
CHILD LOCK
9
Child Lock is used to prevent children from changing the settings of the unit. It can be activated when the
unit is ON by pressing the Fan Key (4) and the Timer Key (3) simultaneously for 5-10 seconds. When the
Child Lock is active, icon 'CL' lights upon the control panel. Now, the keys on the Control Panel and the
Remote Controller will stop working. To deactivate the Child Lock, press again the Fan Key (4) and the
Timer Key (3) simultaneously for 5-10 seconds. When Child Lock is deactivated icon 'CL' goes off on the
Display Panel.
CLEAN FILTER
10
a. In case when CLEAN FILTER indication is 'ON' on the Control Panel, the Plasma Pure Filter (For select
models) needs to be cleaned. Turn 'OFF' the unit and remove Plasma Filter by opening the grill. Then
clean the filter and replace it back to it original position. After this close the grill and turn 'ON' the unit.
The CLEAN FILTER indication goes 'OFF' on the Display Panel. In case it doesn't reset the unit.
b. In case when CLEAN FILTER indication is blinking on the Control Panel, the Anti-Bacteria / Deo-Air Filter
needs to be cleaned. Turn 'OFF' the unit and remove the filter by opening the grill. Then clean the filter
and replace it back to the original position. After this close the grill and turn 'ON' the unit. Then press
the Temperature Down key (5) continuously for 5 seconds. The CLEAN FILTER indication goes 'OFF'
on the Control Panel.
Operation modes may vary in select models.
Fan speed in two steps Low (F1) / High (F2) in select models.
AUTO RESTART
In failure of electric power the unit runs as previous setting operation when power returns.
-10-
ON
About the remote control on the system
The remote control transmits the signals to the system.
Features of the Remote Control- Door Closed
ON
Signal transmitter
3
Flip-up door
(closed)
JET COOL TEMP A/SWING
MODE
Signal transmitter
6
1
3
Flip-up door
(closed)
51
4
2
Signal transmitter
6
5
4
2
1
3
Flip-up door
(closed)
5
4
2
FAN SPEEDPOWER
TYPE ATYPE BTYPE CTYPE D
START/STOP BUTTON
1
Operation starts when this button is
pressed and stops when the button is
pressed again.
OPERATION MODE
2
SELECTION BUTTON
Used to select the operation mode.
INDOOR FAN SPEED
4
SELECTOR
Used to select fan speed in four steps
Low, Medium, High, or CHAOS*.
JET COOL
5
Used to start or stop the speed
cooling. (Speed cooling operates
high fan speed in cooling mode).
ROOM TEMPERATURE
3
SETTING BUTTONS
Used to select the room temperature.
Precaution:
The Remote Control unit will not function properly if strong light strikes the sensor window of the air
conditioner or if there are obstacles between the Remote Control unit and the air conditioner.
AIR SWING BUTTON
6
Used to stop or start vertical louver
movement.
Signal transmitter
A/SWING
POWER
O L
JET C O
51
TEMP
66
FAN SPEED
4
MODE
2
Flip-up door
3
(closed)
Operation Mode
Cooling Mode
Fuzzy Mode
Dry Mode
(Cooling Model)
- Your unit shall have either Type A,Type B, Type C or Type D Remote Control
* Available in selected models. In other models, CHAOS is same as high speed.
-12-
Features of the Remote Control- Door Opened
Signal
transmitter
ON/OFF TIMER BUTTONS
1
Used to set the time of starting and stopping
operation.
Signal
transmitter
ON OFF
1
2
SET
3
8
CANCEL
Signal
transmitter
PLASMA
4
5
6
7
9
JET COOL TEMP A/SWING
FAN SPEEDPOWER
1
2
3
8
ONOFF
TIMERSLEEP
TIMER
SET
CANCEL
PERSONAL MODE
MODE
Signal
transmitter
FAN
ROOM
PLASMA
RESET
4
5
6
7
9
TIME SETTING BUTTONS
2
Used to adjust the time, (See page 21)
TIMER SET/CANCEL BUTTONS
3
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
(See page 21)
SLEEP MODE AUTO BUTTON
4
Used to set Sleep Mode Auto operation.
(See page 21)
FAN MODE BUTTON
5
Used to circulate the room air without cooling
or heating (turns indoor fan on/off).
(See page 22)
ROOM TEMPERATURE
6
CHECKING BUTTON
Used to check the room temperature.
PLASMA (OPTIONAL)
7
Used to start or stop the plasma-purification
function. (See page 18)
4
CANCEL
1
ON
5
2
7
9
OFF
Flip-up door
(opened)
3
SET
6
8
10
1
5
2
7
9
A/SWING
J T COOLE
TEMP
FAN SPEED
MODE SLEEP CANCEL
TIMERONOFFSET
FAN ROOM
TIMER
PERSONAL MODE
POWER
PERSONAL MODE
8
Used to run the unit in Personal Mode
(See page 19)
4
3
6
8
10
RESET BUTTON
9
Used prior to resetting time or after replacing
batteries.
2nd F Button (Type C or Type D
10
Remote Control)
Used prior to using modes printed in blue at
Flip-up door
(opened)
the bottom of buttons. (See page 20)
-13-
How to use the Operation Mode Selection button
Cooling Mode
JET COOL TEMP A/SWING
FAN SPEEDPOWER
Press the Start/Stop button.
The unit will respond with
1
a beep.
Open the door on the remote control. To select CoolingMode, press the Operation Mode Selection button.
2
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
MODE
CoolingFuzzyDry
Close the door on the remote control. Set the temperature
higher than the room temperature. The temperature can be
3
set within a range of 18°C~30°C in 1°C increments.
To raise the temperature
To lower the temperature
POWER
MODE
* Available in selected models. In other models, CHAOS is same as high speed.
Set the fan speed again with the door
of the remote control still closed. You
4
can select the fan speed in four stepslow, medium, high or CHAOS*. Each
time the button is pressed, the fan
speed mode is shifted.
-14-
FAN SPEED
Fuzzy Mode
Press the Start/Stop button.
The unit will respond with
1
a beep.
Open the door on the remote control. To select FuzzyMode, press the Operation Mode Selection button.
2
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
MODE
CoolingFuzzyDry
POWER
JET COOL TEMP A/SWING
FAN SPEEDPOWER
MODE
During Fuzzy Mode :
You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature. If
3
you want to change the set temperature, close the door on
the remote control and press the Room Temperature Setting
buttons. The cooler or warmer you feel, the more times (up to
two times) you should press the button. The set temperature
will be changed automatically.
To raise the temperature
To lower the temperature
-15-
Dry Mode
JET COOL TEMP A/SWING
FAN SPEEDPOWER
Press the Start/Stop button.
The unit will respond with
1
a beep.
Open the door on the remote control. To select Dry Mode,
press the Operation Mode Selection button.
2
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
MODE
CoolingFuzzyDry
POWER
MODE
During Dry Mode :
Unit will run at low fan speed with compressor 'ON'. When compressor is 'OFF', fan will be 'OFF'.
Set temperature cannot be changed.
-16-
Jet Cool Mode
JET COOL TEMP A/SWING
FAN SPEEDPOWER
Press the Start/Stop button.
The unit will respond with
1
a beep.
Press the Jet Cool button to operate
the speed cooling mode and the unit
2
will operate in high fan speed
on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button
again or the fan speed button or the room temperature
3
setting button or the Fan Mode Button.
TEMP
JET COOL
FAN SPEED
oror
POWER
JET COOL
FAN
or
NOTE:
During the JET COOL function at any moment, the A/C starts to blow the cool air at
high speed for 30 minutes setting the room temp. automatically to 18°C. It is
especially used to cool the room temp. in the shortest time in a hot summer.
In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, Fan Speed button or temp. setting button
or the JET COOL button again.
-17-