OWNER’S MANUAL

AIR CONDITIONER

Please read this manual carefully before operating your set and retain it for future reference.

TYPE : Room Air Conditioner

http://www.lghvac.com

P/NO : 3828A20434H

www.lg.com

##############

Room Air Conditioner Ownerʼs Manual

 

TABLE OF CONTENTS

Safety Precautions.........................

3

Prior to Operation ..........................

9

Introduction ..................................

10

Electrical Safety ...........................

11

Operating Instructions.................

12

Maintenance and Service ............

26

FOR YOUR RECORDS

Write the model and serial numbers here:

Model #

Serial #

You can find them on a label on the side of each unit.

Dealer's Name

Date Purchased

Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call for service at all.

PRECAUTION

Contact the authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

The air conditioner is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.

Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.

2 Room Air Conditioner

Safety Precautions

Safety Precautions

To prevent the injury of the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

■ The meanings of the symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

Installation

Do not use damaged power cords, plugs, or a loose socket.

There is risk of fire or electric shock.

Install the panel and the cover of control box securely.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.

There is risk of fire or electric shock.

Do not modify or extend the power cord.

• There is risk of fire or electric

• There is risk of fire or electric

shock.

shock.

Always use the power plug and socket with the ground terminal.

• There is risk of electric shock.

Do not install, remove, or reinstall the unit by yourself (customer).

There is risk of fire, electric shock, explosion or injury.

<![if ! IE]>

<![endif]>ENGLISH

Ownerʼs Manual 3

Safety Precautions

Be cautious when unpacking and installing the product.

Shape edges could cause injury.

Be especially careful of the sharp edges.

Be sure the installation area does not deteriorate with age.

For installation, always contact the dealer or an Authorized Service Center.

There is risk of fire, electric shock, explosion, or injury.

Install the indoor unit on the wall where the height from the floors more then 8ft(2.4m)

Do not install the product on a defective installation stand.

It may cause injury, accident, or damage to the product.

Do not handle the pipe by yourself(Costomer)

If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

• There are sharp moving parts that

• High-Pressure refrigent may cause

could cause personal injury.

personal injury.

8ft(2.4m)

Operation

Do not turn the airconditioner ON or OFF by plugging or unplugging the power plug.

Use a dedicated outlet for this appliance.

Grasp the plug to remove the cord from the outlet. Do not touch it with wet hands.

• There is risk of fire or electric

• There is risk of fire or electric

• There is risk of fire or electric

shock.

shock.

shock.

4 Room Air Conditioner

LG LSU093CE Owners Manual

 

 

Safety Precautions

 

 

 

Use a dedicated outlet for this

Grasp the plug to remove the

Do not allow water to run

appliance.

cord from the outlet. Do not

into electric part.

 

touch it with wet hands.

 

• There is risk of fire or electric

• There is risk of fire or electric

• There is risk of fire, failure of

shock.

shock.

the product, and/or electric

 

 

shock.

Do not place a heater or other

Do not let the air conditioner

appliances near the power

run for a long time when the

cable.

humidity is very high and a

 

door or a window is left open.

• There is risk of fire, failure of the

• Moisture may condense and wet or

product, and/or electric shock.

damage furnishings.

Do not store of use flammable gas or combustibles near the air conditioner.

There is risk of fire or product failure.

<![if ! IE]>

<![endif]>ENGLISH

Wax

Thinner

Do not use the product in a tightly closed space for a long time.

Oxygen deficiency could occur.

Some ventilation by opening window is necessary for the fresh air

When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on. Do not use the telephone or turn switches on or off.

• There is risk of explosion or fire.

Unplug the unit if strange sounds odors or smoke comes from it.

There is risk of fire, Product faiure, and/or electric shock.

Ownerʼs Manual 5

Safety Precautions

Stop operation and close any window in storm or hurricane before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

Ventilate the product from time to time when operating it together with a stove, etc.

There is risk of fire or electrical shock.

Take care to ensure that nobody could step on or fall onto the outdoor unit.

There could result in personal injury and product damage.

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product.

Unplug the appliance before performing cleaning or maintenance.

When the product is soaked (flooded or submerged), contact an Authorized Service Center.

• There is risk of electrical shock.

When the product is not be used for a long time disconnect the power supply plug or turn off the breaker.

• There is risk of electric shock.

• There is risk of product damage or

 

failure, or unintended operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation

 

 

 

Do not insert hands or other

Always check for

objects through the air inlet

gas(refrigerant) leakage after

or outlet while the air

installation or repair of

conditioner is plugged in.

product.

• There are sharp and moving parts

• Low refrigerant levels may cause

that could cause personal injury.

product failure.

6 Room Air Conditioner

 

 

Safety Precautions

 

 

 

 

 

 

Operation

 

 

 

 

Install the drain hose to

Keep level even when

Do not install the product

ensure that water is drained

installing the product.

where the noise or hot air

away properly.

 

from the outdoor unit could

 

 

damage the neighborhoods.

• A bad connection may cause

• To avoid vibration or water

• It may cause a problem for your

water leakage.

leakage.

neighbors.

<![if ! IE]>

<![endif]>ENGLISH

90˚

Use two or more people to lift and transport the air conditioner.

• Avoid personal injury.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

There is risk of damage or loss of property.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion in the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Do not block the inlet or outlet of air flow.

Do not direct airflow at room occupants.

• This could damage your health.

Use a soft cloth to clean.

Do not use harsh detergents, solvents, etc.

• It may cause product failure.

• There is risk of fire, electric shock

 

or damage to the plastic parts of

 

the product.

Ownerʼs Manual 7

Safety Precautions

Do not touch the metal parts of the product when removing the air filter. They are very sharp!

• There is risk of personal injury.

Do not drink the water drained from the unit.

It is not sanitary and could cause serious health issues.

Do not step on or put anything on the product. (outdoor unit)

There is risk of personal injury and failure of product.

Use a firm stool or ladder when cleaning or maintaining the air conditioner.

Be careful and avoid personal injury.

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.

Replace all the batteries in the remote.

• There is risk of fire or explosion.

Disuse

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water.

Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

8 Room Air Conditioner

Prior to operation

Prior To Operation

Preparing For Operation

1.Contact an installation specialist for installation.

2.Plug in the power plug properly.

3.Use a dedicated circuit.

4.Do not use an extension cord.

5.Do not start/stop operation by plugging/unplugging the power cord.

6.If the cord/plug is damaged, ony replace it with an authorized replacement part.

Usage

1.Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time.

2.Ventilate the room when the air conditioner is used with other heating devices. Otherwise the oxygen supply may be inadequate.

3.Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices, food, pets, plants, or art objects). Such use may damage your properties.

Cleaning And Maintenance

1.Do not touch the metal parts of the unit when removing the filter. Injury can occur.

2.Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.

3.When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit power is accidently turned on while the interior of the unit is being cleaned.

Service

For repair and maintenance, contact your authorized service dealer.