• Please read this instruction manual completely before installing the product.
• When the power cord is damaged, replacement should be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
FRANÇAIS ESPAÑOL
2 Room Air Conditioner
Room Air Conditioner Installation Manual
TABLE OF CONTENTS
Safety Precautions .........................3
Introduction .....................................9
Symbols Ued in This Manual......9
Features .......................................9
Installation .....................................10
Installation Parts ........................10
Installation Tools ........................10
Installation Map..........................11
Confirm The Refrigerant ...........12
Select The Best Location .........13
Piping Length And Elevation.....14
How To Mount Installation Plate
..15
Drill a Hole In The Wall..............15
Flaring Work...............................16
Connecting The Piping..............17
Connection Of The Drain Hose
...22
Connection Of Piping -Outdoor
...22
Connection Of The Cable .........23
Checking The Drainage ............25
Forming The Piping ...................26
Air Purging .................................27
Air Purging With Vacuum Pump
..27
Charging.....................................29
Test Running.................................30
Installation guide
at the seaside ................................31
Installation plateFour type "A" screwsConnecting cable
Pipes: Suction line
Evaporator line (Refer to page 13)
Insulation materialsAdditional drain pipe
(
Outer Diameter
.........
15.5mm(0.61in))
Two type "B" screws
Installation
Requirements
Required Parts Required Tools
Level gaugeScrewdriverElectric drillHole core drill(ø70mm(2.76in))
Flaring tool setSpecified torque wrenches
4.2kg.m, 6.6kg.m (different depending on model No.) (Refer to page 17)
Spanner .....................Half union
A glass of waterScrew driver
Hexagonal
wrench(4mm(0.16in))
Gas Leak DetectorVacuum pumpManifold Gauge
Owner's manualThermometerRemote Control Holder
Installation Manual 3
ENGLISH
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Installation
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
Do not use damaged power cords, plugs, or a loose socket.
• There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
• There is risk of fire or electric shock.
Always use the power plug and socket with the ground terminal.
• There is risk of electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Do not modify or extend the power cord.
• There is risk of fire or electric shock.
Do not install, remove, or re­install the unit by yourself (customer).
• There is risk of fire, electric shock, explosion or injury.
4 Room Air Conditioner
Safety Precautions
Operation
Be cautious when unpacking and installing the product.
• Shape edges could cause injury. Be especially careful of the sharp edges.
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
• It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
• If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Install the indoor unit on the wall where the height from the floors more then 1.5m(4.9ft)
• There are sharp moving parts that could cause personal injury.
Do not handle the pipe by yourself(customer)
• High-Pressure refrigent may cause personal injury.
Use a dedicated outlet for this appliance.
• There is risk of fire or electric shock.
Grasp the plug to remove the cord from the outlet. Do not touch it with wet hands.
• There is risk of fire or electric shock.
Do not allow water to run into electric part.
• There is risk of fire, failure of the product, and/or electric shock.
1.5m(4.9ft)
Installation Manual 5
ENGLISH
Safety Precautions
Do not place a heater or other appliances near the power cable.
There is risk of fire, failure of the product, and/or electric shock.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furnishings.
Do not store of use flammable gas or combustibles near the air conditioner.
• There is risk of fire or product failure.
Do not use the product in a tightly closed space for a long time.
• Oxygen deficiency could occur.
• Some ventilation by opeing window is necessary for the fresh air.
When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on. Do not use the telephone or turn switches on or off.
• There is risk of explosion or fire.
Unplug the unit if strange sounds odors or smoke comes from it.
There is risk of fireproduct failure and/or electric shock.
Stop operation and close any window in storm or hurricane. before the hurricane arrives.
• There is risk of property damage, failure of product, or electric shock.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock, or product.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
• There is risk of electrical shock.
Thinner
Wax
6 Room Air Conditioner
Safety Precautions
Installation
Always check for gas(refrigerant) leakage after installation or repair of product.
• Low refrigerant levels may cause product failure.
Install the drain hose to ensure that water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
There could result in personal injury and product damage.
Do not insert hands or other objects through the air inlet or outlet while the air conditioner is plugged in.
There are sharp and moving parts that could cause personal injury.
Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electrical shock.
Unplug the appliance before performing cleaning or maintenance.
There is risk of electric shock.
When the product is not be used for a long time disconnect the power supply plug or turn off the breaker.
There is risk of product damage or failure, or unintended operation.
90˚
Safety Precautions
Installation Manual 7
ENGLISH
Operation
Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and transport the air conditioner
Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion in the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Do not direct airflow at room occupants.
This could damage your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter.They are very sharp!
There is risk of personal injury.
Do not step on or put anything on the product. (outdoor unit)
There is risk of personal injury and failure of product.
8 Room Air Conditioner
Safety Precautions
Disuse
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not drink the water drained from the unit.
It is not sanitary and could cause serious health issues.
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other
health hazards.
Use a firm stool or ladder when cleaning or maintaining the air conditioner.
Be careful and avoid personal injury.
Replace all the batteries in the remote.
There is risk of fire or explosion.
Installation Manual 9
ENGLISH
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Introduction
Symbols Used In This Manual
Features
Air Intake Vents
Air Outlet Vents
Connecting Wires
Piping
Drain Hose
Base Plate
Air Outlet Vents
Air Intake Vents
Piping
Connecting Wires
Drain Hose
Signal Receptor
Base Plate
Front Panel
Air Inlet
Air Filter
10 Room Air Conditioner
Installation
Type "A" screw and plastic anchor
Type "B" screw
Remote Control Holder
Installation plate
Figure FigureName
Screw driver
Electric Drill
Measuring Tape, Knife
Hole Core Drill
Spanner
Torque wrench
Ohmmeter
Hexagonal wrench
Ammeter
Gas Leak Detector
Thermometer,
Level
Flaring Tool Set
Name
Installation Parts
Installation Tools
Installation