Please read this installation manual completely before installing the
product. Installation work must be performed in accordance with the
national wiring standards by authorized personnel only. This equipment shall
be provided with a supply conductor complying with the national regulation.
Original instruction (R410A/R32)
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro,
Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA
This manual is the simplified version of original manual.
You can obtain the original manual from www.lg.com.
MFL70280701
Rev.08_072120
ENGLISH
ITALIANO
ESPAÑOL
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
2
Airborne Noise Emission
The A-weighted sound pressure emitted by
this product is below 70 dB.
The noise level can vary depending on the
site.
The figures quoted are emission level and are
not necessarily safe working levels.
Whilst there is a correlation between the
emission and exposure levels, this cannot be
used reliably to determine whether or not
further precautions are required.
Factor that influence the actual level of
exposure of the workforce include the
characteristics of the work room and the other
sources of noise, i.e. the number of
equipment and other adjacent processes and
the length of time for which an operator
exposed to the noise. Also, the permissible
exposure level can vary from country to
country.
This information, however, will enable the
user of the equipment to make a better
evaluation of the hazard and risk.
Limiting concentration
Limiting concentration is the limit of Freon gas
concentration where immediate measures
can be taken without hurting human body
when refrigerant leaks in the air. The limiting
concentration shall be described in the unit of
kg/m3(Freon gas weight per unit air volume)
for facilitating calculation.
Product information
- Product Name : Air conditioner
- Model Name :
Product Sales Name Model Factory Name
ARNa***Gxy# series
a = U(DC Inverter and H/P and C/O) ,
H(Hydro Kit)
x = Chassis Name
y = Combinations of functions
*** = Numeric; (Cooling capacity)
# = Numeric; (Series No)
- Additional Information : serial number is
refer to the barcode on the product.
- Max Allowable water temperature
High side : 80 °C / Low side : 10 °C
(ARNH***Gxy# series)
- Allowable water pressure
~ 0.98 MPa (0.3~10 kg f/cm
(ARNH***Gxy# series)
2
)
Limiting concentration: 0.44 kg/m3(R410A)
Refrigerant
concentration
(kg/m3)
Total amount of replenished
refrigerant in refrigerant facility (kg)
=
Capacity of smallest room where
indoor unit is installed (m
3
)
SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
The following symbols are displayed on indoor and outdoor units.
Read the precautions in this manual
carefully before operating the unit.
This symbol indicates that the
Operation Manual should be read
carefully.
The following safety guidelines are intended to prevent
unforeseen risks or damage from unsafe or incorrect operation
of the appliance.
The guidelines are separated into ‘WARNING’ and ‘CAUTION’ as
described below.
This symbol is displayed to indicate matters and operations
!
that can cause risk.
Read the part with this symbol carefully and follow the
instructions in order to avoid risk.
WARNING
!
This indicates that the failure to follow the instructions can cause
serious injury or death.
This appliance is filled with
flammable refrigerant. (for R32)
This symbol indicates that a service
personnel should be handling this
equipment with reference to the
Installation Manual.
3
ENGLISH
CAUTION
!
This indicates that the failure to follow the instructions can cause
the minor injury or damage to the product.
WARNING
!
• Installation, repairs or breakdown made by unqualified
persons can result in hazards to you and others.
• The information contained in the manual is intended for use
by a qualified service technician familiar with safety
procedures and equipped with the proper tools and test
instruments.
• Failure to carefully read and follow all instructions in this
manual can result in equipment malfunction, property
damage, personal injury and/or death.
• Compliance with national gas regulations shall be observed.
ENGLISH
SAFETY INSTRUCTIONS
4
Installation
• Have all electric work done by a licensed electrician according
to "Electric Facility Engineering Standard" and "Interior Wire
Regulations" and the instructions given in this manual and
always use a special circuit.
- If the power source capacity is inadequate or electric work is
performed improperly, electric shock or fire may result.
• Compliance with national gas regulations shall be observed.
• Ask the dealer or an authorized technician to install the air
conditioner.
- Improper installation by the user may result in water
leakage, electric shock, or fire.
• Always ground the product.
- There is risk of fire or electric shock.
• Ducts connected to an appliance shall not contain an ignition
source. (for R32)
• Always install a dedicated circuit and breaker.
- Improper wiring or installation may cause fire or electric
shock.
• For re-installation of the installed product, always contact a
dealer or an Authorized Service Center.
- There is risk of fire, electric shock, explosion, or injury.
• Do not install, remove, or re-install the unit by yourself
(customer).
- There is risk of fire, electric shock, explosion, or injury.
• Do not store or use flammable gas or combustibles near the
air conditioner.
- There is risk of fire or failure of product.
• Use the correctly rated breaker or fuse.
- There is risk of fire or electric shock.
• Prepare for strong wind or earthquake and install the unit at
the specified place.
- Improper installation may cause the unit to topple and result
in injury.
• Do not install the product on a non-parallel or defective
installation stand.
- It may cause injury, accident, or damage to the product.
• Use a vacuum pump or Inert(nitrogen) gas when doing
leakage test or air purge. Do not compress air or Oxygen and
do not use Flammable gases. Otherwise, it may cause fire or
explosion.
SAFETY INSTRUCTIONS
- There is the risk of death, injury, fire or explosion.
• When installing and moving the air conditioner to another site,
do not charge it with a different refrigerant from the
refrigerant specified on the unit.
- If a different refrigerant or air is mixed with the original
refrigerant, the refrigerant cycle may malfunction and the
unit may be damaged.
• Do not reconstruct to change the settings of the protection
devices.
- If the pressure switch, thermal switch, or other protection
device is shorted and operated forcibly, or parts other than
those specified by LGE are used, fire or explosion may
result.
• Ventilate before operating air conditioner when gas leaked
out.
- It may cause explosion, fire, and burn.
• Securely install the cover of control box and the panel.
- If the cover and panel are not installed securely, dust or
water may enter the outdoor unit and fire or electric shock
may result.
• If the air conditioner is installed in a small room, measures
must be taken to prevent the refrigerant concentration from
exceeding the safety limit when the refrigerant leaks.
- Consult the dealer regarding the appropriate measures to
prevent the safety limit from being exceeded. Should the
refrigerant leak and cause the safety limit to be exceeded,
hazards due to lack of oxygen in the room could result.
• The appliance shall be stored in a well-ventilated area where
the room size corresponds to the room area as specified for
operation. (for R32)
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an
operating gas appliance or an operating electric heater.)
• Keep any required ventilation openings clear of obstruction.
• Mechanical connections shall be accessible for maintenance
purposes.
• To prevent the mixing of different types of refrigerants, be
sure to check the type of refrigerant used in the outdoor unit.
- The mixing of refrigerants could lead to malfunctioning.
5
ENGLISH
ENGLISH
SAFETY INSTRUCTIONS
6
Operation
• Do not damage or use an unspecified power cord.
- There is risk of fire, electric shock, explosion, or injury.
• Use a dedicated outlet for this appliance.
- There is risk of fire or electrical shock.
• Be cautious that water could not enter the product.
- There is risk of fire, electric shock, or product damage.
• Do not touch the power switch with wet hands.
- There is risk of fire, electric shock, explosion, or injury.
• When the product is soaked (flooded or submerged), contact
an Authorized Service Center.
- There is risk of fire or electric shock.
• Be cautious not to touch the sharp edges when installing.
- It may cause injury.
• Take care to ensure that nobody could step on or fall onto the
unit.
- This could result in personal injury and product damage.
• Do not open the inlet grille of the product during operation.
(Do not touch the electrostatic filter, if the unit is so
equipped.)
- There is risk of physical injury, electric shock, or product
failure.
• Take care to ensure that power cable could not be pulled out
or damaged during operation.
- There is risk of fire or electric shock.
• When mechanical connectors are reused indoors, sealing
parts shall be renewed. (for R32)
• When flared joints are reused indoors, the flare part shall be
re-fabricated. (for R32)
• Periodic ( more than once/year ) cleaning of the dust or salt
particles stuck on the heat exchanger by using water.
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
• Do not pierce or burn refrigerant cycle part.
• Be aware that refrigerants may not contain an odour.