Selection of Leuze electronic Safety Switches from left
to right:
S20
Normal Duty Safety Switch,
S300
Safety
Position Switch,
S200
Heavy Duty Safety Switch,
S400
Safety Hinge Switch
Safety Switches selection table Selection table
Safety Switch for guarding the sliding door on a pick-and-place
machine
Features, type-dependent
Safety Position Switch on machine with a protective device and
swivel joints – a typical application, e.g. in automated parts
processing
Safety Switches are used for the position monitoring of moving
protective devices, such as protective doors or flaps. Safety
Switches without guard interlocking can always be used when
the dangerous movement has stopped before the entering
person can reach the point of operation. The Leuze electronic
Safety Switches portfolio also includes Safety Position Switches
(S300) and Safety Hinge Switches (S400) and therefore provides the perfect solution for many different applications.
NC contact for
safety circuit
NO contact for
signal circuit
1) With step function against contact bounces
2) Second hinge available separately
Description Article Page
Safety Switch with separate actuator
S20 series
Safety Switch with separate actuator
S200 series
Safety Position Switch
S300 series
Safety Hinge Switches
S400, S410 series
z
z
z
z
z
Plastic housing
Metal housing
Safety Switches
contact set
NC =
NO =
2NC S20-P3C1-M20-FH 356
1NC + 1NO S20-P1C1-M20-FH 356
1NC + 1NO S20-P1C3-M20-LH 356
2NC + 1NO S20-P4C1-M20-FH 356
2NC + 1NO S20-P4C3-M20-LH 356
2NC S200-M3C1-M20 368
z
1NC + 1NO S200-M1C1-M20 368
z
2NC + 1NO S200-M4C1-M20 368
z
z
z
z
z
z
z
z
z
z
z
1)
1NC
2NC + 1NO S300-M13C3-M20-15 378
1NC
2NC + 1NO S300-M13C3-M20-31 378
2NC + 1NO S400-M4CB2-B2) 384
2NC + 1NO S400-M4M12-B2) 384
2NC + 1NO S400-M4CB2-T
2NC + 1NO S400-M4M12-T
2NC + 1NO S410-M1CB2-B
2NC + 1NO S410-M1M12-B
+ 1NO S300-M0C3-M20-15 378
1)
+ 1NO S300-M0C3-M20-31 378
2)
2)
2)
2)
384
384
384
384
352
S20
p. 354
We reserve the right to make changes • 11-0.fm © 2010 Leuze electronic GmbH + Co. KG We reserve the right to make changes • 11-0.fm © 2010 Leuze electronic GmbH + Co. KG
S200
p. 366
S300
p. 376
S400, S410
p. 382
www.leuze.com/sid/
353
Safety Switches
Safety Locking
Devices
Safety Command
Devices Safety Relays
Configurable
Safety Relays AccessoriesGlossary Product Finder
SAFETY LOCKING DEVICES OVERVIEW
The Leuze electronic Safety Locking
Devices completely cover the entire
spectrum from normal to very high
requirements (from left to right):
L10, L100, L200
Safety Locking Devices selection table Selection table
Safety Locking Device as access guarding
Safety Locking Device on a metal processing center with
stopping times
Safety Locking Devices keep the protective door locked and
therefore prevent inadmissible access by people. The access to
the danger zone is only released by an electric signal when
either the dangerous movement has stopped (personnel protection) or an uninterruptible work process has been finished
(machine protection). All Leuze electronic Safety Switches and
Locking Devices are configured with their robust design for use
in tough industrial applications and prove their value under the
most demanding operational conditions.
1)
Description Article Page
Plastic housing
Metal housing
Locking, manual
Spring force-actuated guard interlocking
z z
Safety Locking Device
L10 series
z z
z z
z z
Safety Locking Device
L100 series
z z z
zz
z z z
Safety Locking Device
L200 series
zzz
z z
zzz
Features, type-dependent
2)
NC contact for safety circuit
Auxiliary unlocking, manual
Magnet-actuated guard interlocking
Safety Locking contact set
NC =
2NC L10-P2C1-M20-SB20 396
2NC L10-M2C1-M20-SB20 396
2NC + 1NO L10-P3C1-M20-SB20 396
2NC + 1NO L10-M3C1-M20-SB20 396
1NC + 1NO 1NC L100-P3C3-M20-SLM24 402
1NC + 1NO 1NC L100-P3C3-M20-MLM24 402
2NC 1NC L100-P4C3-M20-SLM24 402
2NC 1NC + 1NO L200-M1C3-SLM24-L2G 410
2NC 1NC + 1NO L200-M1C3-MLM24-L2G 410
2NC 1NC + 1NO L200-M1C3-SLM24-PB-L2G 410
NO contact for signal circuit
NO =
Door opener contact set
NC contact for safety circuit
NC =
NO contact for signal circuit
1) Closed current principle, personnel protection
2) Closed current principle, personnel protection
NO =
392
L10
p. 394
We reserve the right to make changes • 12-0.fm © 2010 Leuze electronic GmbH + Co. KG We reserve the right to make changes • 12-0.fm © 2010 Leuze electronic GmbH + Co. KG
L100
p. 400
L200
p. 408
www.leuze.com/sid/