Leuze ODSR 96B Data Sheet

18 - 30 V
DC
IEC 60947...
IEC 60947...
IPIP 69K69K IPIP 6767
A Indicator diode green B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12 x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and key pad I Reference edge for the measurement (cover glass)
ODSR 96B Optical distance sensors
Dimensioned drawing
en 04-2012/11 50107947
100 … 600mm
Reflection-independent distance
information
Highly insensitive to extraneous lightAnalogue current or voltage outputPC/OLED display and key pad for
Measurement value is indicated in mm on
OLED display
Measurement range and mode adjustableTeachable switching output and analogue
output
Accessories:
(available separately)
Mounting systemsCable with M12 connector (K-D …)Configuration software
Electrical connection
We reserve the right to make changes • DS_ODSR96BMCV6600_en_50107947.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
• www.leuze.com
ODSR 96B M/C6-600-S12 - 04
ODSR 96B M/V6-600-S12 - 04
ODSR 96B
Specifications
Optical data
Measurement range Resolution Light source LED Wavelength 635nm (visible red light) Light spot approx. 15 x 15mm Laser warning notice see remarks
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy Repeatability b/w detect. thresholds (6 … 90% rem.)  1% Temperature compensation yes
Timing
Measurement time 1 … 51)ms Response time Delay before start-up  300 ms
Electrical data
Operating voltage U Residual ripple 15 % of UB Open-circuit current  150 mA Switching output push-pull switching output
Signal voltage high/low  (UB-2 V)/ 2V Analogue output voltage 1 … 10V, R
Indicators teach-in on GND teach-in on +U
Green LED continuous light ready
Yellow LED continuous light object inside teach-in measurement distance
Mechanical data Metal housing
Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +50°C / -30 °C … +70°C Protective circuit VDE safety class Protection class IP 67, IP 69K LED class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2
1) Luminosity coefficient 6 % … 90 %, complete measurement range, at 20 °C, medium range of UB, measurement object
50x 50mm²
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object 50 x50 mm²
4) Typ. ± 0.02 %/K
5) The push-pull switching outputs must not be connected in parallel
6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
7) Rating voltage 250 VAC, with cover closed
8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test.
1)
3)
1)
B
flashing fault teaching procedure off no voltage
flashing teaching procedure off object outside teach-in measurement distance
6)
7)
1)
100 … 600mm
0.1 … 0.5mm
2
at 600mm
±1.5% ±0.5%
4)
15 ms
18 … 30VDC (incl. residual ripple)
5)
PNP light switching, NPN dark switching
current 4 … 20mA, RL 500
1, 2, 3 II, all-insulated
L
8)
A Area not defined B Linearity not defined C Measurement range D Object present E No object detected F Measurement distance
,
2k
B
Tables
Diagrams
Remarks
Measurement time
depends on the reflectivity of the measurement object and on the mea­surement mode.
Approved purpose:
The ODSR 96B distance sensors are optical elec­tronic sensors for the opti­cal, contactless measure­ment of distance to objects.
Order guide
Designation Part No.
With M12 connector
Current output ODSR 96B M/C6-600-S12 501 06730 Voltage output ODSR 96B M/V6-600-S12 501 06731
ODSR 96B M/C6-600-S12 - 04 2012/11 ODSR 96B M/V6-600-S12 - 04