A Indicator diode green
B Indicator diode yellow
C Transmitter
D Receiver
E Optical axis
F Device plug M12 x1
G Countersinking for SK nut M5, 4.2mm deep
H OLED display and key pad
I Reference edge for the measurement (cover glass)
ODSR 96B Optical distance sensors
Dimensioned drawing
en 04-2012/11 50107947
100 … 600mm
Reflection-independent distance
information
Highly insensitive to extraneous light
Analogue current or voltage output
PC/OLED display and key pad for
configuration
Measurement value is indicated in mm on
OLED display
Measurement range and mode adjustable
Teachable switching output and analogue
output
Accessories:
(available separately)
Mounting systems
Cable with M12 connector (K-D …)
Configuration software
Electrical connection
We reserve the right to make changes • DS_ODSR96BMCV6600_en_50107947.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
• www.leuze.com
ODSR 96B M/C6-600-S12 - 04
ODSR 96B M/V6-600-S12 - 04

ODSR 96B
Specifications
Optical data
Measurement range
Resolution
Light source LED
Wavelength 635nm (visible red light)
Light spot approx. 15 x 15mm
Laser warning notice see remarks
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy
Repeatability
b/w detect. thresholds (6 … 90% rem.) 1%
Temperature compensation yes
Timing
Measurement time 1 … 51)ms
Response time
Delay before start-up 300 ms
Electrical data
Operating voltage U
Residual ripple 15 % of UB
Open-circuit current 150 mA
Switching output push-pull switching output
Signal voltage high/low (UB-2 V)/ 2V
Analogue output voltage 1 … 10V, R
Indicators teach-in on GND teach-in on +U
Green LED continuous light ready
Yellow LED continuous light object inside teach-in measurement distance
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +50°C / -30 °C … +70°C
Protective circuit
VDE safety class
Protection class IP 67, IP 69K
LED class 1 (acc. to EN 60825-1)
Standards applied IEC 60947-5-2
1) Luminosity coefficient 6 % … 90 %, complete measurement range, at 20 °C, medium range of UB, measurement object
50x 50mm²
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object 50 x50 mm²
4) Typ. ± 0.02 %/K
5) The push-pull switching outputs must not be connected in parallel
6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
7) Rating voltage 250 VAC, with cover closed
8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives.
Acids and bases are not part of the test.
1)
3)
1)
B
flashing fault teaching procedure
off no voltage
flashing teaching procedure
off object outside teach-in measurement distance
6)
7)
1)
100 … 600mm
0.1 … 0.5mm
2
at 600mm
±1.5%
±0.5%
4)
15 ms
18 … 30VDC (incl. residual ripple)
5)
PNP light switching, NPN dark switching
current 4 … 20mA, RL 500
1, 2, 3
II, all-insulated
L
8)
A Area not defined
B Linearity not defined
C Measurement range
D Object present
E No object detected
F Measurement distance
,
2k
B
Tables
Diagrams
Remarks
Measurement time
depends on the reflectivity
of the measurement
object and on the measurement mode.
Approved purpose:
The ODSR 96B distance
sensors are optical electronic sensors for the optical, contactless measurement of distance to
objects.
Order guide
Designation Part No.
With M12 connector
Current output ODSR 96B M/C6-600-S12 501 06730
Voltage output ODSR 96B M/V6-600-S12 501 06731
ODSR 96B M/C6-600-S12 - 04 2012/11
ODSR 96B M/V6-600-S12 - 04