Leuze ODSLR 96B Data Sheet

18 - 30 V
DC
IEC 60947...
IEC 60947...
IPIP 69K69K IPIP 6767
A Green indicator diode B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12 x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display and membrane keyboard I Reference edge for the measurement (cover glass)
ODSLR 96B M/V6-…-S12
ODSLR 96B M/C6-…-S12
ODSLR 96B Optical laser distance sensors
Dimensioned drawing
en 05-2012/11 50110336
60 … 2000mm
Reflection-independent distance
information
Highly insensitive to extraneous lightAnalog current or voltage outputPC/OLED display and membrane keyboard
Measurement value is indicated in mm on
OLED display
Measurement range and mode adjustableTeachable switching output and analog
output
Accessories:
(available separately)
Mounting systemsCable with M12 connector
(K-D …)
Configuration software
Electrical connection
We reserve the right to make changes • DS_ODSLR96BMCV62000_en_50110336.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.de • www.leuze.com
ODSLR 96B M/C6-2000-S12 - 05
ODSLR 96B M/V6-2000-S12 - 05
ODSLR 96B
Specifications
Optical data
Measurement range Resolution Light source red light laser/LED Wavelength laser 655 nm/LED 635nm (visible red light) Light spot divergent, 2x6 mm
Laser warning notice see Remarks
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy Repeatability B/W detection thresh. (6 … 90% rem.)  1% Temperature compensation yes
Timing
Measurement time 1 … 51)ms Response time Delay before start-up  300 ms
Electrical data
Operating voltage UB 18 … 30VDC (incl. residual ripple) Residual ripple 15 % of UB Open-circuit current  150 mA Switching output push-pull switching output
Signal voltage high/low  (UB-2 V)/ 2V Analog output voltage 1 … 10V, RL 2k
Indicators Teach-in on GND Teach-in on +U
Green LED continuous light ready
Yellow LED continuous light object inside teach-in measurement distance
Mechanical data Metal housing
Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector
Environmental data
Ambient temp. (operation/storage) -20°C … +50°C / -30 °C … +70°C Protective circuit VDE safety class Protection class IP 67, IP 69K Laser class 2 (acc. to EN 60825-1) Standards applied IEC 60947-5-2
1) Luminosity coefficient 6% … 90%, complete measurement range, at 20°C, medium range of UB, measurement object
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object 50 x50 mm²
4) Typ. ± 0.02 %/K
5) The push-pull switching outputs must not be connected in parallel
6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
7) Rating voltage 250 VAC, with cover closed
8) IP 69K test in accordance with DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test
1)
3)
1)
flashing fault teach event off no voltage
flashing teach event off object outside teach-in measurement distance
6)
7)
50x 50mm²
1)
60 … 2000mm 1…5mm
2
at 2m
LED approx. 15x15mm
± 2% 60 … 200mm / ± 1.5 % 200 … 2000mm ±0.5%
4)
15 ms
PNP light switching, NPN dark switching
current 4 … 20mA, RL 500 
1, 2, 3 II, all-insulated
8)
A Area not defined B Linearity not defined C Measurement range D Object present E No object detected F Measurement distance
2
at 200mm
5)
,
B
Tables
Diagrams
Remarks
Measurement time
depends on the reflectivity of the measurement object and on the mea­surement mode.
Approved purpose:
The ODSLR 96B distance sensors are optoelec­tronic sensors for the opti­cal, contactless measure­ment of distance to objects.
50 60 2000 2100 ca. 30000
Order guide
Designation Part no.
With M12 connector
Current output ODSLR 96B M/C6-2000-S12 501 06732 Voltage output ODSLR 96B M/V6-2000-S12 501 06733
ODSLR 96B M/C6-2000-S12 - 05 2012/11 ODSLR 96B M/V6-2000-S12 - 05
Loading...