ODSL 96B M/C6-2000 Ex d
ODSL 96B M/L-2000 Ex d
ODSL 96B Ex d Optical laser distance sensors
Dimensioned drawing
en 06-2017/02 50108369-03
150 … 2000mm
Reflection-independent distance
information
Highly insensitive to extraneous light
Analog current output
Configurable measurement range and
measure mode
Configuration via PC/OLED display and key
pad (the sensor must be removed from the
Ex housing for this purpose)
Teachable switching output and analog
output
EC type examination certificate
DEKRA 13 ATEX 0209
II 2G Ex d op is IIB+H
2
T4 Gb
II 2D Ex tb IIIC T135°C Db
Cable 15m, 5-wire
Accessories:
(available separately)
Configuration software
Electrical connection
We reserve the right to make changes • PAL_ODSL96BEx_en_50108369_03.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 7021 5730
info@leuze.com • www.leuze.com
ODSL 96B … Ex d - 06

ODSL 96B Ex d
Specifications
Optical data
Measurement range
Resolution
Light source laser
Laser class 2 in accordance with IEC 60825-1:2007
Wavelength 650nm
Max. output power 1.2mW
Pulse duration 22ms
Light spot divergent, 2x6 mm² at 2 m
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy
Repeatability
B/W detection thresh. (6 … 90% rem.) ≤ 1%
Temperature compensation yes
Timing
Measurement time 1 … 51)ms
Response time
Delay before start-up ≤ 300 ms
Electrical data
Operating voltage UB 18 … 30V DC (incl. residual ripple)
Residual ripple ≤ 15 % of U
Open-circuit current ≤ 150 mA
Outputs ODSL 96B M/C6-2000 Ex d
Switching output push-pull switching output 5),
Signal voltage high/low ≥ (UB-2 V)/≤ 2V
Analog output voltage 1 … 10V, R
Sensor operating mode ODSL 96B M/L-2000 Ex d
IO-Link COM2 (38.4kBaud), Frame 2.2, Vers. 1.0,
SIO
Indicators Teach-in on GND Teach-in on +U
Green LED continuous light ready
Yellow LED continuous light object inside teach-in measurement distance
Mechanical data Metal housing
Housing diecast zinc
Optics cover glass
Weight 380g
Connection type Cable 15m, 5-wire
Environmental data
Ambient temp. (operation/storage) -20°C … +50°C/-30°C … +70°C
Protective circuit
VDE safety class
Protection class IP 66, IP 67
Standards applied IEC 60947-5-2
Explosion protection
Certification (CENELEC) II 2G Ex d op is IIB+H2 T4 Gb
1) Luminosity coefficient 6 % … 90 %, complete measurement range, at 20°C, medium range of UB, measurement object
≥ 50x 50 mm²
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object ≥ 50x50 mm²
4) Typ. ± 0.02 %/K
5) The push-pull switching outputs must not be connected in parallel
6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
7) Rating voltage 250 VAC, with cover closed
1)
3)
1)
flashing fault teach event
off no voltage
flashing teach event
off object outside teach-in measurement distance
6)
7)
1)
150 … 2000mm
1…3mm
±1,5%
±0,5%
4)
≤ 15 ms
B
PNP light switching, NPN dark switching
≥ 2kΩ
current 4 … 20mA, RL≤ 500Ω
min. cycle time 2.2ms
not supported
1, 2, 3
II, all-insulated
II 2D Ex tb IIIC T135°C Db
L
B
Tables
Diagrams
Remarks
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
Order guide
Designation Part no.
Cable connection, 15m
Current output ODSL 96B M/C6-2000 Ex d 50106735
Measurement time
depends on the reflectivity
of the measurement
object and on the
measurement mode.
IO-Link interface ODSL 96B M/L-2000 Ex d 50136154
ODSL 96B … Ex d - 06 2017/02