Leuze ODSL 9 Data Sheet

18 - 30 V
DC
U
L
US
C
LISTED
IP 67
IEC 60947...
IEC 60947...
A Reference edge for the measurement B Optical axis C Device plug M12 D Receiver E Transmitter F LCD display G Indicator diode yellow H Green indicator diode J Control buttons
ODSL 9/V6…
ODSL 9/C6…
ODSL 9 Optical laser distance sensors
Dimensioned drawing
en 01-2014/07 50126802
50 … 200mm
High resolution 0.01mm, from
50 … 100mm
Reflection-independent distance
information
PC/LC display and control buttons for
Measurement value is indicated with 0.01
mm resolution on LC display
Configurable measure mode and measure-
ment range
Input (pin 2) for deactivation of laser, trig-
gering, offset correction, reference measurement or teach-in
M12 turning connector
Electrical connection
Accessories:
(available separately)
Mounting systemsConfiguration softwareCable with M12 connector
(K-D …)
We reserve the right to make changes • DS_ODSL9200_en_50126802.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.de • www.leuze.com
ODSL 9/…-200-… - 01
ODSL 9
Specifications
Optical data
Measurement range Resolution
Light source laser Wavelength 655nm Light spot divergent, 1x 1 mm
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy
Repeatability
B/W detection thresh. (6 … 90% rem.)  0.5 % Temperature compensation yes
1)
1)
3)
50 … 200mm
0.01mm from 50 … 100mm,
0.1mm from 100 … 200mm
± 0.5% from 50 … 100mm ± 1% from 100 … 200mm ± 0.25% from 50 … 100mm ± 0.5% from 100 … 200mm
4)
2
at 100mm
Tables
Timing
Measurement time 2ms Response time 1) 6ms Delay before start-up  300 ms
Electrical data
Operating voltage U Residual ripple 15 % of U Open-circuit current  180 mA Switching output push-pull switching output 6),
Signal voltage high/low  (UB-2 V)/ 2V Analog output …V6 voltage 1…10V / 0…10V / 1…5V / 0…5V, RL 2k
Indicators Teach-in on GND Teach-in on +U
Green LED continuous light ready
Yellow LED continuous light object inside teach-in measurement distance
5)
B
…C6/V6
flashing fault teach event
flashing teach event
18 … 30V DC (incl. residual ripple)
PNP light switching, NPN dark switching
…C6
current 4 … 20mA, RL 500 
off no voltage
off object outside teach-in measurement distance
B
B
Diagrams
Mechanical data
Housing plastic Optics cover glass Weight approx. 50 g Connection type M12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) -20°C … +50°C / -30 °C … +70 °C Protective circuit VDE safety class Degree of protection IP 67 Laser class 2 (according to EN 60825-1 and 21 CFR 1040.10 with Laser
Standards applied IEC 60947-5-2 Certifications UL 508, C22.2 No.14-13
1) Luminosity coefficient 6 % … 90 %, complete measurement range, "Standard" operating mode, at 20 °C, medium range of U
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object 50 x 50mm²
4) Typ. ± 0.02 %/K
5) For UL applications: for use in class 2 circuits according to NEC only
6) The push-pull switching outputs must not be connected in parallel
7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
8) Rating voltage 50 VAC
9) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
7)
8)
, measurement object 50x 50 mm²
B
1, 2, 3 II, all-insulated
Notice No. 50)
5) 9)
Remarks
Operate in accordance with intended use!
This product is not a safety sensor
and is not intended as personnel protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
Order guide
Designation Part no.
Analog current output
1 teachable push/pull output ODSL 9/C6-200-S12 50117334
Analog voltage output
1 teachable push/pull output ODSL 9/V6-200-S12 50113332
ODSL 9/…-200-… - 01 2014/07
Measurement time
depends on the reflectivity of the measurement object and on the mea­surement mode.
AVOID EXPOSURE – LASER RADIATION
IS EMITTED FROM THIS APERTURE
EXPOSITION DANGEREUSE – UN RAYONNEMENT
LASER EST ÉMIS PAR CETTE OUVERTURE
LASERSTRAHLUNG
NICHT IN DEN STRAHL BLICKEN
LASER KLASSE 2
DIN EN 60825-1:2008-05
Max. Leistung (peak): Impulsdauer: Wellenlänge:
RADIAZIONE LASER
NON FISSARE IL FASCIO
APARRECCHIO LASER DI CLASSE 2
EN 60825-1:2007
Potenza max. (peak): Durata dell'impulso: Lunghezza d'onda:
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
EN 60825-1:2007
Maximum Output (peak): Pulse duration: Wavelength:
RAYONNEMENT LASER
NE PAS REGARDER DANS LE FAISCEAU
APPAREIL À LASER DE CLASSE 2
EN 60825-1:2007
Puissance max. (crête): Durée d`impulsion: Longueur d`onde:
RADIACIÓN LÁSER
NO MIRAR FIJAMENTE AL HAZ
PRODUCTO LÁSER DE CLASE 2
EN 60825-1:2007
Potencia máx. (peak): Duración del impulso: Longitud de onda:
RADIAÇÃO LASER
NÃO OLHAR FIXAMENTE O FEIXE
EQUIPAMENTO LASER CLASSE 2
EN 60825-1:2007
Potência máx. (peak): Período de pulso: Comprimento de onda:
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
EN 60825-1:2007
Complies with 21 CFR 1040.10
Maximum Output (peak): Pulse duration: Wavelength:
䉏⏘戟⺓
▎䦃展⏘㧮
伊䉏⏘ℶ❐
GB7247.1-2012
㦏⮶戢⒉᧤⽿⋋᧥ 厘⑁㖐兼㢅梃 㽱栎
1,2 mW
22 ms
650 nm
1,2 mW
22 ms
650 nm
1.2 mW 22 ms
650 nm
1,2 mW
22
m
s
650 nm
1,2 mW
22 ms
650 nm
1,2 mW
22 ms
650 nm
1.2 mW 22 ms
650 nm
1.2 mW 22 ms
650 nm
50106507-04
A Laser exit opening
A
B
ODSL 9 Optical laser distance sensors
Laser safety notices
ATTENTION, LASER RADIATION – LASER CLASS 2
Never look directly into the beam!
The device fulfills the EN 60825-1:2008-05 (IEC 60825-1:2007) safety regulations for a product in laser class 2 as well as the U.S. 21 CFR 1040.10 regulations with deviations corresponding to "Laser Notice No. 50" from June 24th, 2007.
Never look directly into the laser beam or in the direction of reflecting laser beams!
If you look into the beam path over a longer time period, there is a risk of injury to the retina.
Do not point the laser beam of the device at persons!Intercept the laser beam with an opaque, non-reflective object if the laser beam is accidentally directed towards a person.When mounting and aligning the device, avoid reflections of the laser beam off reflective surfaces!CAUTION! Use of controls or adjustments or performance of procedures other than specified herein may result in hazardous light
exposure. The use of optical instruments or devices (e.g., magnifying glasses, binoculars) with the product will increase eye hazard.
Adhere to the applicable legal and local regulations regarding protection from laser beams acc. to EN 60825 (IEC 60825) in its latest
version.
The device must not be tampered with and must not be changed in any way.
There are no user-serviceable parts inside the device. Repairs must only be performed by Leuze electronic GmbH + Co. KG.
NOTICE
Affix laser information and warning signs!
Laser information and warning signs are affixed to the device(see (stick-on labels) are supplied in several languages (see
).
Affix the laser information sheet with the language appropriate for the place of use to the device.
When using the device in the US, use the stick-on label with the "Complies with 21 CFR 1040.10" notice.
Affix the laser information and warning signs near the device if no signs are attached to the device (e.g. because the device is too
small) or if the attached laser information and warning signs are concealed due to the installation position. Affix the laser information and warning signs so that they are legible without exposing the reader to the laser radiation of the device
or other optical radiation.
). In addition, self-adhesive laser information and warning signs
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODSL 9/…-200-… - 01 info@leuze.de • www.leuze.com
Analog output: characteristic curve for factory setting
A Area not defined B Linearity not defined C Measurement range D Object present E No object detected F Measurement distance
From approx. 650mm, measurement value "0" is displayed and 0V/0mA is output at analog output.
ODSL 9
ODSL 9/…-200-… - 01 2014/07