![](/html/f3/f34f/f34fc6b0fc7bec993b5f21f381ba5d10e27109bd24f23588343c9409bdcc7b2c/bg1.png)
A Reference edge for the measurement
B Optical axis
C Device plug M12
D Receiver
E Transmitter
F LCD display
G Indicator diode yellow
H Green indicator diode
J Control buttons
ODSL 9 Optical laser distance sensors
Dimensioned drawing
en 01-2014/07 50126802
50 … 200mm
High resolution 0.01mm, from
50 … 100mm
Reflection-independent distance
information
PC/LC display and control buttons for
configuration
Measurement value is indicated with 0.01
mm resolution on LC display
Configurable measure mode and measure-
ment range
Input (pin 2) for deactivation of laser, trig-
gering, offset correction, reference
measurement or teach-in
M12 turning connector
Electrical connection
Accessories:
(available separately)
Mounting systems
Configuration software
Cable with M12 connector
(K-D …)
We reserve the right to make changes • DS_ODSL9200_en_50126802.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
info@leuze.de • www.leuze.com
ODSL 9/…-200-… - 01
![](/html/f3/f34f/f34fc6b0fc7bec993b5f21f381ba5d10e27109bd24f23588343c9409bdcc7b2c/bg2.png)
ODSL 9
Specifications
Optical data
Measurement range
Resolution
Light source laser
Wavelength 655nm
Light spot divergent, 1x 1 mm
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy
Repeatability
B/W detection thresh. (6 … 90% rem.) 0.5 %
Temperature compensation yes
1)
1)
3)
50 … 200mm
0.01mm from 50 … 100mm,
0.1mm from 100 … 200mm
± 0.5% from 50 … 100mm
± 1% from 100 … 200mm
± 0.25% from 50 … 100mm
± 0.5% from 100 … 200mm
4)
2
at 100mm
Tables
Timing
Measurement time 2ms
Response time 1) 6ms
Delay before start-up 300 ms
Electrical data
Operating voltage U
Residual ripple 15 % of U
Open-circuit current 180 mA
Switching output push-pull switching output 6),
Signal voltage high/low (UB-2 V)/ 2V
Analog output …V6 voltage 1…10V / 0…10V / 1…5V / 0…5V, RL 2k
Indicators Teach-in on GND Teach-in on +U
Green LED continuous light ready
Yellow LED continuous light object inside teach-in measurement distance
5)
B
…C6/V6
flashing fault teach event
flashing teach event
18 … 30V DC (incl. residual ripple)
PNP light switching, NPN dark switching
…C6
current 4 … 20mA, RL 500
off no voltage
off object outside teach-in measurement distance
B
B
Diagrams
Mechanical data
Housing plastic
Optics cover glass
Weight approx. 50 g
Connection type M12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) -20°C … +50°C / -30 °C … +70 °C
Protective circuit
VDE safety class
Degree of protection IP 67
Laser class 2 (according to EN 60825-1 and 21 CFR 1040.10 with Laser
Standards applied IEC 60947-5-2
Certifications UL 508, C22.2 No.14-13
1) Luminosity coefficient 6 % … 90 %, complete measurement range, "Standard" operating mode, at 20 °C,
medium range of U
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object 50 x 50mm²
4) Typ. ± 0.02 %/K
5) For UL applications: for use in class 2 circuits according to NEC only
6) The push-pull switching outputs must not be connected in parallel
7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
8) Rating voltage 50 VAC
9) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
7)
8)
, measurement object 50x 50 mm²
B
1, 2, 3
II, all-insulated
Notice No. 50)
5) 9)
Remarks
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
Order guide
Designation Part no.
Analog current output
1 teachable push/pull output ODSL 9/C6-200-S12 50117334
Analog voltage output
1 teachable push/pull output ODSL 9/V6-200-S12 50113332
ODSL 9/…-200-… - 01 2014/07
Measurement time
depends on the reflectivity
of the measurement
object and on the measurement mode.