ODSL 8 Optical laser distance sensors
Dimensioned drawing
en 09-2017/11 50103923-03
20 … 500mm
Reflection-independent distance
information
2 teachable switching outputs (push-pull)
M12 turning connector
Easy alignment through visible red light
Accessories:
(available separately)
Mounting systems
Cable with M12 connector (KD …)
Control guard
A Receiver
B Transmitter
C Optical axis
D 90° turning connector
E LED yellow, green
F Operational control (rotary switch)
G Reference edge for the measurement (cover glass)
Electrical connection
We reserve the right to make changes • PAL_ODSL8_66_500_en_50103923_03.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
info@leuze.com • www.leuze.com
ODSL 8/66-500-S12 - 09
A Hysteresis
B Switching point Q1 (teach point)
C Switching point Q2 (teach point)
D Measurement distance
ODSL 8
Specifications
Optical data
Measurement range
Resolution
Hysteresis
Light source laser
Laser class 2 acc. to IEC 60825-1:2007
Wavelength 650nm (visible red light)
Max. output power <1.2 mW
Pulse duration 4ms
Light spot 2x 6 mm
2)
2)
Error limits (relative to measurement distance)
Absolute measurement accuracy
Repeatability
B/W detection thresh. (6 … 90% rem.) ≤ 1.5%
Temperature drift ≤ 0.2%/°C
Timing
Measurement time 2 … 7ms
Response time ≤ 20ms
Delay before start-up ≤ 300ms
Electrical data
Operating voltage U
Residual ripple ≤ 15 % of UB
Open-circuit current ≤ 50mA
Switching output/function
Signal voltage high/low ≥ (U
Indicators
Green LED continuous light ready
Yellow LED continuous light object within teach-in measurement distance (output Q1
Mechanical data
Housing metal
Optics cover glass
Weight 70g
Connection type M 12 connector, 5-pin, turning
Environmental data
Ambient temp. (operation/storage) -40°C … +50°C/-40°C … +70 °C
Protective circuit
VDE safety class
Protection class
Environmentally tested acc. to ECOLAB
Standards applied IEC 60947-5-2
1) Luminosity coefficient 6 % … 90 %, at 20 °C, measurement object ≥ 50x 50 mm²
2) Minimum and maximum value depend on measurement distance
3) Same object, identical environmental conditions, measurement object ≥ 50x50 mm²
4) The push-pull switching outputs must not be connected in parallel
5) No display for output Q2
6) 2=polarity reversal protection, 3=short-circuit protection for all outputs
7) Rating voltage 250 VAC
8) In stop position of the turning connector (turning connector locked)
9) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
Characteristic curve of switching outputs:
1)
3)
B
4)
flashing (no teach) fault, teach values were not applied
off no voltage
flashing (no teach) teach values were not applied
off object outside teach-in measurement distance (output Q1 4))
6)
7)
8)
20 … 500mm
0.1 … 0.5mm
0.6 … 32mm
2
at 500mm
1)
± 2% up to 200mm / ± 4 % 200 … 500 mm
± 1% up to 200mm / ± 3 % 200 … 500 mm
10 … 30VDC (incl. residual ripple)
2 push-pull switching outputs
pin 2: Q2, PNP light switching, NPN dark switching
pin 4: Q1, PNP light switching, NPN dark switching
-2 V)/≤ 2V
B
2, 3
II, all-insulated
IP 67, IP 69K
9)
Tables
Diagrams
5)
)
Remarks
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
Order guide
With M12 connector ODSL 8/66-500-S12 50101880
ODSL 8/66-500-S12 - 09 2017/11
Measurement time
depends on the reflectivity
of the measurement
object and on the
measurement mode.
Designation Part no.