Leuze ODSIL 96B Data Sheet

Page 1
18 - 30 V
DC
IEC 60947...
IEC 60947...
IPIP 69K69K IPIP 6767
A Green indicator diode B Indicator diode yellow C Transmitter (infrared light) for distance measurement D Receiver E Optical axis F Device plug M12 x1 G Countersinking for SK nut M5, 4.2mm deep H OLED display I Reference edge for the measurement (cover glass) K Key pad L Green and yellow indicator diodes M Transmitter (red light) as alignment aid N Button for switching red alignment laser on/off
ODSIL 96B M/C6… ODSIL 96B M/V6…
ODSIL 96B Optical laser distance sensors
Dimensioned drawing
en 03-2013/01 50114025
0.3 … 10m
Measurement range up to 10000mm at
90% diffuse reflection
Reflection-independent distance informa-
tion up to 6000mm
Infrared laser diode with laser class 1Switchable alignment aid with red light laser
diode with laser class 1
Highly insensitive to extraneous lightAnalog current or voltage outputPC/OLED display and membrane keyboard
for configuration
Measurement value is indicated in mm on
OLED display
Measurement range and mode adjustableInput (pin 2) for deactivation of laser, trig-
gering, offset correction or teach-in
Electrical connection
Accessories:
(available separately)
Mounting systemsCable with M12 connector
(K-D …)
We reserve the right to make changes • DS_ODSIL96BMTOF_en_50114025.fm
Configuration software
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
ODSIL 96B M/… - 03
Page 2
ODSIL 96B
Specifications
Optical data
Measurement range 300 … 10000mm (90% diffuse reflection),
Resolution 3mm Light source laser Wavelength measurement laser: 785nm (infrared light),
Light spot approx. 7x7 mm² at 10 m Max. output power measurement laser: 268mW,
Pulse duration measurement laser: 6.5 ns,
Error limits (relative to measurement range end value 6000mm)
Absolute measurement accuracy Repeatability B/W detection thresh. (6 … 90% rem.) ± 10mm Temperature drift ± 1.5mm/K
2)
1)
300 … 6000mm (6 … 90% diffuse reflection)
alignment laser: 658nm (visible red light)
alignment laser: 190mW
alignment laser: 6.5ns
±0.5% ±5mm
Timing
Measurement time "Fast" operating mode: 2.8ms
Delay before start-up  300 ms
"Standard" operating mode: 20ms "Precision" operating mode: 100ms (factory setting)
Electrical data
Operating voltage U Residual ripple 15 % of UB Open-circuit current  150mA Switching output push-pull switching output
Signal voltage high/low  (UB-2 V)/2V Analog output
B
…C6/V6 18 … 30VDC (incl. residual ripple)
3)
PNP light switching, NPN dark switching
…V6 voltage 1…10V / 0…10V / 1…5V / 0…5V, R
…C6
current 4 … 20mA, RL 500 
,
2k
L
Indicators Teach-in on GND
Green LED continuous light ready
Yellow LED continuous light object within range / switching output
off no voltage
off object out of range / switching output
Mechanical data Metal housing
Housing diecast zinc Optics cover glass Weight 380g Connection type M 12 connector
Environmental data
Ambient temp. (operation/storage) -20 °C … +50°C / -30°C … +70°C Protective circuit VDE safety class Protection class IP 67, IP 69K Laser class 1 (acc. to EN 60825-1) Standards applied IEC 60947-5-2
1) For 300 … 6000mm measurement range, luminosity coefficient 6% … 90 %, "Precision" operating mode, floating average calculation taking 30 measurement values into account, at 20°C after 20 min. warmup time, medium range
, measurement object 50x 50mm²
of U
B
2) Same object, identical environmental conditions, "Precision" operating mode, floating average calculation taking 30 measurement values into account, after 20 min. warmup time, measurement object
3) The push-pull switching outputs must not be connected in parallel
4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
5) Rating voltage 250 VAC, with cover closed
6) IP 69K test in accordance with DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives. Acids and bases are not part of the test
4)
5)
1, 2, 3 II, all-insulated
6)
50 x50 mm²
Order guide
Designation Part no.
Analogue current output
Current output, teach input, 1 push/pull output ODSIL 96B M/C6-S12 50109302
Analogue voltage output
Voltage output, teach input, 1 push/pull output ODSIL 96B M/V6-S12 50109303
Tables
Diagrams
Remarks
Approved purpose:
This product may only be used by qualified person­nel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons.
The red light laser diode is
used exclusively as an alignment aid. The beam radiates at a distance of 17mm parallel to the infra­red measurement beam (see dimensioned draw­ing).
ODSIL 96B M/… - 03 2013/01
Page 3
FactorySettings Execute
ODSIL 96B Optical laser distance sensors
Analog output: characteristic curve for factory setting
Factory setting
A Area not defined B Linearity not defined C Measurement range D Object present E No object detected F Measurement distance
200 300 6000 6300
Measurement mode and measurement filter
The user can individually adapt the measurement system of the ODSIL 96B to various applications. By configuring the measure­ment mode and measurement filter, either a higher measurement accuracy or, alternatively, faster measurements can be achieved. Configuration can be performed either directly on the sensor or with the ODS 96B configuration software.
Optimization of measurement mode
In the Application menu, you can set 3 different measurement filters.
Menu setting Effect
Application -> Measure Mode -> Precision high accuracy, measurement time of individual measurement: 100ms Application -> Measure Mode -> Standard exact and fast, measurement time of individual measurement: 20ms Application -> Measure Mode -> Speed fast measurement, measurement time of individual measurement: 2.8ms
Optimization of measurement filter
To achieve more precise measurement values, a measurement filter can be adjusted in addition to the measurement mode. In most cases, the use of a floating average results in a reduction in the variance of the measurement values. To use this, select the menu setting Application -> Measure Filter -> Averaging.
The number of measurement values to be taken into account can be set to a value between 1…99 via menu setting Application -> Measure Filter -> Averaging -> Measurem. Count.
Notice!
The measurement value display on the OLED display can be used to assess the efficiency of the selected measurement mode and measurement filter in the application. The update rate of the OLED display is always 2Hz. The ODS 96B con­figuration software provides identical functionality.
Factory setting of measurement mode:
On delivery, the sensor is preset so that measurement values with the maximum possible accuracy are achieved:
Measurement mode Precision.
Reset to factory settings
Press the  button while switching on the device to reset the configuration of the ODSIL 96B to the state upon delivery from the factory.
Press the viously are permanently lost.
Press and the ODSIL 96B returns to measurement operation without resetting the parame­ters.
You can also use the menu or the configuration software to reset to factory settings. For this purpose, select menu item Settings -> FactorySettings -> Execute.
The ODS 96B configuration software can also be used to reset the ODSIL 96B to factory settings.
button again to reset all parameters to the factory settings. All settings made pre-
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODSIL 96B M/… - 03
Page 4
Inactive Low 0V
T
t
Active High +24V
ODSIL 96B
Teach-in of switching outputs, analog characteristic output curve and Preset
Notice!
If you have changed the factory setting for teaching under Input Mode, activate on the OLED display the menu item Input -> Input Mode -> Teach.
To teach, proceed as follows:
1.Position measurement object at the desired measurement distance.
2.The respective teach function is activated on the teach input for the duration of a level change T (see graphical representation).
The level conditions describe the levels with menu setting Input -> Input Mode -> Input polarity -> Active High +24V (factory setting).
Teach function Duration T
Switching output Q1 20 … 80ms Distance value for start of measurement range =
1V or 4mA at analog output Distance value for end of measurement range =
10V or 20mA at analog output
Notice!
If the inactive level is continuously applied on the teach input, the teach input is locked.
For menu setting Input -> Input Mode -> Input polarity -> Active Low +0V, inverted input signals are used during teaching.
220 … 280ms
320 … 380ms
Preset Teach-In
On the OLED display, activate for this purpose menu item Input -> Input Mode -> Preset.
The preset teach occurs in a manner analogous to that for the teach-in for switching output Q1.
ODSIL 96B M/… - 03 2013/01
Loading...