Leuze ODS10 Data Sheet

IP 67
IEC 60947...
IEC 60947...
A Reference edge for the measurement B Optical axis C Turning M12 connector, 90° D Receiver E Transmitter F OLED display G Indicator diodes green/red (control panel)
2 x yellow (control panel and lens cover)
H Membrane keyboard
Q1 Q2
18-30V DC +
4-20mA
GND
IN
BN WH BU BK GY
ODS10L1-25M.8/LAK-M12 ODS10L1-25M.8/LAK,200-M12 ODS10L1-25M.8/LAK
ODS10 Optical distance sensors
Dimensioned drawing
en 04-2016/08 50129321
100 … 25000mm
Measurement range up to 25000mm on
HighGain foil
Analog current and voltage output (factory
setting: current output)
configuration
Configurable measurement range and mea-
sure mode
IO-Link version 1.1Measurement value display in mm on OLED
display
Optional input for deactivation of the laser
(factory setting) or for teach-in
Accessories:
(available separately)
HighGain reflective tape REF 7-A-100x100
(Part no. 50111527)
Mounting systemsCable with M12 connector (K-D …)IO-Link master set
SET MD12-US2-IL1.1 + accessories ­diagnostics set (part no. 50121098)
We reserve the right to make changes • DS_ODS10L1_25M8L_en_50129321.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.com • www.leuze.com
Electrical connection
18-30V DC +
4-20mA
GND
1 2 3 4
IN
5
ODS10L1-25M.8/L… - 04
Measurement distance [m]
Reproducibility [mm]
Typ. Reproducibility on HighGain tape
(measure mode "Standard", 50ms)
ODS10
Technical data
Measurement data
Measurement range 100 … 25000mm (on HighGain tape) Resolution 1mm Accuracy ±25mm Reproducibility 0.5 … 4mm Response time 3.4 … 1020 ms, adjustable3), see tables Output time 3.4ms 4), see tables Temperature drift ≤ ±2mm/K
1)
2)
Optical data
Light source laser Laser class 1 (acc. to IEC 60825-1:2007) Wavelength 658 nm (visible red light) Impulse duration 6ns Max. output power (peak) 391mW Light spot approx. 7x7mm² at 8m
Timing
Measurement time “Fast” measure mode: 15 ms
Readiness delay ≤ 300 ms
“Standard” measure mode: 50 ms (factory setting) “Precision” measure mode: 200 ms “High precision” measure mode: 1000 ms for individual measure modes, see Page 3
Electrical data
Operating voltage UB 5) Residual ripple 15% of UB Open-circuit current ≤ 150mA Switching output push-pull switching output
Signal voltage high/low ≥ (UB-2V)/2V Analog output
ODS10L1-25M.8/LA… voltage 1 … 10V / 0 … 10 V / 1 … 5 V / 0 … 5 V, R
IO-Link COM2 (38.4kBaud), vers. 1.1, min. cycle time 2.3ms,
18 … 30VDC (incl. residual ripple)
6)
PNP light switching, NPN dark switching
,
current 4 … 20mA, RL≤ 500Ω (factory setting)
SIO is supported
Indicators
Green/red LED Green continuous light ready
Yellow LEDs Q1/Q2 On object detected
Red no signal Orange warning, weak signal Off no voltage
Mechanical data
Housing plastic Optics cover glass Weight 70g (M 12 connector)
Connection type turning M12 connector, 90°
133g (2 m cable) 90g (cable with M 12 connector)
2m cable, wire cross section 5 x 0.14mm² (5 x 26 AWG)
0.2m cable with M12 connector
Environmental data
Ambient temp. (operation/storage) -40°C … +50°C/-40°C … +70 °C Protective circuit VDE safety class III Degree of protection IP 67 Standards applied IEC 60947-5-2 Certifications UL 508, CSA C22.2 No.14-13
1) Typical values, measurement range 100 … 25000 mm, measurement on HighGain foil REF 7-A-100x100, response time 50 ms, “Standard” measure mode, at 20°C after warmup time of 20 min.
2) Typical values, statistical value 1 sigma, measurement on HighGain foil REF 7-A-100x100, at 20°C after warmup time of 20 min.
3) Factory setting: “Standard” 50 ms
4) Factory setting, with filter functions adjustable from 17 … 1020ms
5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
6) The push-pull switching outputs must not be connected in parallel
7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
7)
1, 2, 3
5) 8)
Notes
You can download the IO Device Description (IODD file) and the Sensor Studio configuration
software (requires IO-Link USB master) from the Internet at www.leuze.com
.
2kΩ
L
Tables
Measure modes:
Measure mode Response time Output time
Fast 15ms 3.4ms Standard 50ms 3.4ms Precision 200ms 3.4ms High precision 1000ms 3.4ms
1)
Individual Spike
suppression 1)
1) See “Individual measure modes” on Page 3
3.4…1020ms 3.4ms 17…1020ms 17…1020 ms
Diagrams
6
5
4
3
2
1
0
0102051525
Notes
Observe intended use!
This product is not a safety sensor
and is not intended as personnel protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.
ODS10L1-25M.8/L… - 04 2016/08
Loading...
+ 4 hidden pages