A Reference edge for the measurement
B Optical axis
C Turning M12 connector, 90°
D Receiver
E Transmitter
F OLED display
G Indicator diodes green/red (control panel)
2 x yellow (control panel and lens cover)
H Membrane keyboard
Q1
Q2
18-30V DC +
4-20mA
GND
IN
BN
WH
BU
BK
GY
ODS10L1-25M.8/LAK-M12
ODS10L1-25M.8/LAK,200-M12 ODS10L1-25M.8/LAK
ODS10 Optical distance sensors
Dimensioned drawing
en 04-2016/08 50129321
100 … 25000mm
Measurement range up to 25000mm on
HighGain foil
Analog current and voltage output (factory
setting: current output)
OLED display and membrane keyboard for
configuration
Configurable measurement range and mea-
sure mode
IO-Link version 1.1
Measurement value display in mm on OLED
display
Optional input for deactivation of the laser
(factory setting) or for teach-in
Accessories:
(available separately)
HighGain reflective tape REF 7-A-100x100
(Part no. 50111527)
Mounting systems
Cable with M12 connector (K-D …)
IO-Link master set
SET MD12-US2-IL1.1 + accessories diagnostics set (part no. 50121098)
We reserve the right to make changes • DS_ODS10L1_25M8L_en_50129321.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
info@leuze.com • www.leuze.com
Electrical connection
18-30V DC +
4-20mA
GND
1
2
3
4
IN
5
ODS10L1-25M.8/L… - 04
Measurement distance [m]
Reproducibility [mm]
Typ. Reproducibility on HighGain tape
(measure mode "Standard", 50ms)
ODS10
Technical data
Measurement data
Measurement range 100 … 25000mm (on HighGain tape)
Resolution 1mm
Accuracy ≤ ±25mm
Reproducibility 0.5 … 4mm
Response time 3.4 … 1020 ms, adjustable3), see tables
Output time 3.4ms 4), see tables
Temperature drift ≤ ±2mm/K
1)
2)
Optical data
Light source laser
Laser class 1 (acc. to IEC 60825-1:2007)
Wavelength 658 nm (visible red light)
Impulse duration 6ns
Max. output power (peak) 391mW
Light spot approx. 7x7mm² at 8m
Timing
Measurement time “Fast” measure mode: 15 ms
Readiness delay ≤ 300 ms
“Standard” measure mode: 50 ms (factory setting)
“Precision” measure mode: 200 ms
“High precision” measure mode: 1000 ms
for individual measure modes, see Page 3
Electrical data
Operating voltage UB 5)
Residual ripple ≤ 15% of UB
Open-circuit current ≤ 150mA
Switching output push-pull switching output
Signal voltage high/low ≥ (UB-2V)/≤ 2V
Analog output
ODS10L1-25M.8/LA… voltage 1 … 10V / 0 … 10 V / 1 … 5 V / 0 … 5 V, R
IO-Link COM2 (38.4kBaud), vers. 1.1, min. cycle time 2.3ms,
18 … 30VDC (incl. residual ripple)
6)
PNP light switching, NPN dark switching
,
current 4 … 20mA, RL≤ 500Ω (factory setting)
SIO is supported
Indicators
Green/red LED Green continuous light ready
Yellow LEDs Q1/Q2 On object detected
Red no signal
Orange warning, weak signal
Off no voltage
Mechanical data
Housing plastic
Optics cover glass
Weight 70g (M 12 connector)
Connection type turning M12 connector, 90°
133g (2 m cable)
90g (cable with M 12 connector)
2m cable, wire cross section 5 x 0.14mm² (5 x 26 AWG)
0.2m cable with M12 connector
Environmental data
Ambient temp. (operation/storage) -40°C … +50°C/-40°C … +70 °C
Protective circuit
VDE safety class III
Degree of protection IP 67
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 No.14-13
1) Typical values, measurement range 100 … 25000 mm, measurement on HighGain foil REF 7-A-100x100, response
time 50 ms, “Standard” measure mode, at 20°C after warmup time of 20 min.
2) Typical values, statistical value 1 sigma, measurement on HighGain foil REF 7-A-100x100,
at 20°C after warmup time of 20 min.
3) Factory setting: “Standard” 50 ms
4) Factory setting, with filter functions adjustable from 17 … 1020ms
5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
6) The push-pull switching outputs must not be connected in parallel
7) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
7)
1, 2, 3
5) 8)
Notes
You can download the IO Device Description (IODD file) and the Sensor Studio configuration
software (requires IO-Link USB master) from the Internet at www.leuze.com
.
≥ 2kΩ
L
Tables
Measure modes:
Measure mode Response time Output time
Fast 15ms 3.4ms
Standard 50ms 3.4ms
Precision 200ms 3.4ms
High precision 1000ms 3.4ms
1)
Individual
Spike
suppression 1)
1) See “Individual measure modes” on
Page 3
3.4…1020ms 3.4ms
17…1020ms 17…1020 ms
Diagrams
6
5
4
3
2
1
0
0102051525
Notes
Observe intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.
ODS10L1-25M.8/L… - 04 2016/08