Leuze HTU318 Data Sheet

10 - 30 V
DC
IP 67
IEC 60947...
IEC 60947...
HTU318 Ultrasonic sensors with 2 switching outputs
Dimensioned drawing
en 01-2017/02 50135816
50 … 400mm
150 … 1600mm
Function largely independent of surface
properties, ideal for detection of liquids, bulk materials, transparent media, …
Small dead zone at long scanning rangeAdjustment of the switching point can be
taught
(PNP or NPN)
NEW – Both outputs can easily be taught
using a button
NEW – Stable plastic designNEW – Temperature-compensated
scanning range
Accessories:
(available separately)
Mounting systemsMounting adapter M18-M30:
BTX-D18M-D30 (Part no. 50125860)
Cables with M12 connector
(KD …)
A Active sensor surface B Teach-in button C Indicator diodes
Electrical connection
We reserve the right to make changes • PAL_HTU318_400_1600_2SWO_en_50135816.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
HTU318-400…-M12 - 01
HTU318-1600…-M12 - 01
Object distance x [mm]
Width y of the sound cone [mm]
Typ. response behavior (plate 200x 200mm)
-100
-50
0
50
100
0 100 200 300 400 500
y1
y2
Object distance x [mm]
Width y of the sound cone [mm]
Typ. response behavior (rod Ø 25 mm)
y1
y2
-300
-200
0
100
-100
200
300
0 400 800 16001200
Object distance x [mm]
Width y of the sound cone [mm]
Typ. response behavior (plate 200x 200mm)
y1
y2
-300
-200
0
100
-100
200
300
0 400 800 16001200
Object distance x [mm]
Width y of the sound cone [mm]
Typ. response behavior (rod Ø 25 mm)
Object distance [mm]
Target (fixed):
plate or rod
Sound cone
= f (α,x)
HTU318
Technical data
Ultrasonic specifications HTU318-400.3/…-M12 HTU318-1600.3/…-M12
Scanning range Adjustment range 50 … 400mm 150 … 1600mm Ultrasonic frequency 300kHz 230kHz Typ. opening angle 8° ± 2 ° 8° ± 2 ° Resolution <2mm <2mm Direction of beam Axial Axial Reproducibility ± 0.5% Switching hysteresis 1% 3) 1% Temperature drift ≤ 5%
Timing
Switching frequency 10Hz 2Hz Response time 500ms 250ms Readiness delay < 500ms < 500 ms
Electrical data
Operating voltage U Residual ripple ± 7% of U Open-circuit current ≤ 50mA Switching output / Function …/4P… 2 independent PNP transistor switching outputs
Output current Max. 100 mA Switching range adjustment 1-point teach: teach-in button 2 … 7s,
Changeover NO/NC
Indicators
Yellow LED OUT1: object detected Blue LED OUT2: object detected Flashing yellow or blue LED Teach-in Flashing green and yellow/blue LEDs Teaching error Green LED Object within the scanning range
Mechanical data
Housing Plastic (PBT) Active surface Epoxy resin, glass fiber reinforced Weight 70g
Ultrasonic transducer Piezoceramic
Connection type M 12 connector, 5-pin Fitting position Any
Environmental data
Ambient temp. (operation/storage) -20° … +70°C/-20° … +70°C Protective circuit VDE protection class III Degree of protection IP 67 Standards applied EN 60947-5-2 Certifications UL 508, CSA C22.2 No.14-13
1) At 20°C
2) Target: 200mm x 200 mm plate
3) From end value
4) Over the temperature range -20°C … +70°C
5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
6) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)
7) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
1)
5)
B
50 … 400mm 2)
1) 3)
4)
150 … 1600mm 2)
±0.5% 1)
3)
5% 4)
10 … 30V DC (incl. ± 7% residual ripple)
B
3)
OUT 1 (pin 4): NO contact preset
…/2N… 2 independent NPN transistor switching outputs
OUT 2 (pin 5): NC contact preset
OUT 1 (pin 4): NO contact preset OUT 2 (pin 5): NC contact preset
2-point teach: teach-in button 7 … 12s Teach-in button > 12s
6)
7)
1, 2, 3
5) 8)
Diagrams
HTU318-400.3/…-M12
100
50
0
-50
-100 0 100 200 300 400 500
HTU318-1600.3/…-M12
y2
y1
HTU318-400…-M12 - 01 2017/02 HTU318-1600…-M12 - 01
Notes
Observe intended use!
This product is not a safety sensor
and is not intended as personnel protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.
HTU318 Ultrasonic sensors with 2 switching outputs
Part number code
HTU318-1600 . 3 /4PK-M12
Operating principle HTU Ultrasonic sensor, scanning principle, with background suppression DMU Ultrasonic sensor, distance measurement RKU Ultrasonic sensor, retro-reflective ultrasonic sensor
Series 318 318 series, cylindrical short M18 design
Scanning range in mm 400 50 … 400 1600 150 … 1600
Equipment .3 Teach button on the sensor
Pin assignment of connector pin 4 / black cable wire (OUT1) 4 PNP output, NO contact preset P PNP output, NC contact preset 2 NPN output, NO contact preset N NPN output, NC contact preset
Pin assignment of connector pin 2 / white cable wire (Analog OUT/OUT2) 4 PNP output, NO contact preset P PNP output, NC contact preset 2 NPN output, NO contact preset N NPN output, NC contact preset C Analog output 4 … 20 mA V Analog output 0 … 10 V
Pin assignment of connector pin 5 / gray cable wire (Sync / MUX) K Synchronization/multiplex input
Connection technology M12 M12 connector, 5-pin
Order guide
The sensors listed here are preferred types; current information at www.leuze.com.
Designation Part no.
Scanning range / switching output / teach-in
50 … 400mm / 2 x PNP / teach button HTU318-400.3/4PK-M12 50136082 50 … 400mm / 2 x NPN / teach button HTU318-400.3/2NK-M12 50136083 150 … 1600mm / 2 x PNP / teach button HTU318-1600.3/4PK-M12 50136088 150 … 1600mm / 2 x NPN / teach button HTU318-1600.3/2NK-M12 50136089
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 HTU318-400…-M12 - 01
HTU318-1600…-M12 - 01